CoChat

Reliability, validity, and responsiveness of three scales for measuring balance in patients with chronic stroke

Open access
Alghadir, Ahmad H., Al-Eisa, Einas S., Anwer, Shahnawaz, Sarkar, Bibhuti · 2018 · BMC Neurology
Cited by 200

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Various outcome measures are used for the assessment of balance and mobility in patients with stroke. The purpose of the present study was to examine test-retest reliability, construct validity, and responsiveness of the Timed Up and Go Test (TUG), Berg Balance Scale (BBS), and Dynamic Gait Index (DGI) for measuring balance in patients with chronic stroke. METHODS: Fifty-six patients (39 male and 17 female) with chronic stroke participated in this study. A senior physical therapist assessed the test-retest reliability and validity of three scales, including the DGI, TUG, and BBS over two testing sessions. In addition, the third assessment of each scale was taken at the time of discharge to determine the responsiveness of the three outcome measures. RESULTS: = 0.99) were excellent. The standard error of measurement (SEM) of the TUG, DGI, and BBS were 1.16, 0.71, and 0.98, respectively. The minimal detectable change (MDC) of the TUG, DGI, and BBS were 3.2, 1.9, and 2.7, respectively. There was a significant correlation found between the DGI and BBS (first reading [r] = 0.75; second reading [r] = 0.77), TUG and BBS (first reading [r] = -.52; second reading [r] = -.53), and the TUG and DGI (first reading [r] = 0.45; second reading [r] = 0.48), respectively. CONCLUSIONS: The test-retest reliability of the TUG, BBS, and DGI was excellent. The DGI demonstrated slightly better responsiveness than TUG and BBS. However, the small sample size of this study limits the validity of the results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s12883-018-1146-9

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Metadata

Authors
Alghadir, A. H., Al-Eisa, E. S., Anwer, S., & Sarkar, B.
Venue
BMC Neurology
Published
2018-09-13
Volume
18
Issue
1
Pages
141-141
ISSN
1471-2377 (ISSN-L)
OpenAlex
W2890330833
Cited by
200
References
2
FWCI
6.49
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reliability, validity, and responsiveness of three scales for measuring balance in patients with chronic stroke. https://app.cochat.ai/papers/10.1186/s12883-018-1146-9
The paper
Alghadir, A. H., Al-Eisa, E. S., Anwer, S., & Sarkar, B. (2018). Reliability, validity, and responsiveness of three scales for measuring balance in patients with chronic stroke. BMC Neurology. https://doi.org/10.1186/s12883-018-1146-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.