Evaluation of a novel vital sign device to reduce maternal mortality and morbidity in low-resource settings: a mixed method feasibility study for the CRADLE-3 trial
Open accessAbstract
BACKGROUND: The CRADLE-3 trial is a stepped-wedge randomised controlled trial aiming to reduce maternal mortality and morbidity by implementing a novel vital sign device (CRADLE Vital Sign Alert) and training package into routine maternity care in 10 low-income sites. The MRC Guidance on complex interventions proposes that interventions and implementation strategies be shaped by early phase piloting and development work. We present the findings of a three-month mixed-methodology feasibility study for this trial, describe how this was informed by the MRC guidance and the study design was refined. METHODS: The fidelity, dose, feasibility and acceptability of implementation and training materials were assessed in three representative non-trial sites (Zimbabwe, Ethiopia, India) using multiple-choice questionnaires, evaluation of clinical management (action log), healthcare provider (HCP) semi-structured interviews and focus groups 4-10 weeks after implementation. Simultaneously, the 10 sites included in the main trial (eight countries) collected primary outcome data to inform the power calculation and randomisation allocation and assess the feasibility of data collection. RESULTS: The package was implemented with high fidelity (85% of HCP trained, n = 204). The questionnaires indicated a good understanding of device use with 75% of participants scoring > 75% (n = 97; 90% of those distributed). Action logs were inconsistently completed but indicated that the majority of HCP responded appropriately to abnormal results. From 18 HCP interviews and two focus groups it was widely reported that the intervention improved capacity to make clinical decisions, escalate care and make appropriate referrals. Nine of the ten main trial sites achieved ethical approval for pilot data collection. Intensive care was an inconsistent marker of morbidity and stroke an infrequent outcome and therefore they were removed from the main trial composite outcome. Tools and methods of data collection were optimized and event rates used to inform randomisation. CONCLUSIONS: This feasibility study demonstrates that the components of the intervention were acceptable, methods of implementing were successful and the main trial design would be feasible. Qualitative work identified key moderators that informed the main trial process evaluation. Changes to the training package, implementation strategy, study design and processes were identified to refine the implementation in the main trial. TRIAL REGISTRATION: ISRCTN41244132 ; Registered 24/11/2015.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Respondents generally found the CRADLE device easy to use, but small errors in application (e.g. incorrect positioning) could lead to staff mistrust.
“In keeping with earlier CRADLE studies [10, 12, 27], respondents generally found the device easy to use, but small errors in application (e.g. incorrect positioning) could lead to staff mistrust.”
From Scale-up of a novel vital signs alert device to improve maternity care in Sierra Leone: a mixed methods evaluation of adoption (2023) · cites this paper as [27]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 19 · Cited by 30
Research works printed but not linked: 4
- [2]World Health Organisation. The world health report 2005: make every mother and child count, vol. 2005. Geneva: World Health Organization.
- [15]Nathan HL, Boene H, Munguambe K, Sevene E, Akeju D, Adetoro OO, Charanthimath U, Bellad MB, de Greeff A, Anthony J, Hall DR, Steyn W, Vidler M, von Dadelszen P, Chappell LC, Sandall J, Shennan AH, and the CLIP Working Group. The CRADLE vital signs alert: qualitative evaluation of a novel device designed for use in pregnancy by healthcare workers in low-resource settings. BMC Reproductive Health. 2018;15(1):5. PMC5756409 29304812
- [20]World Health Organisation. WHO recommendations for prevention and treatment of pre-eclampsia and eclampsia. 2011 http://apps.who.int/iris/bitstream/10665/44703/1/9789241548335_eng.pdf. [Accessed 3rd April 2017]. 23741776
- [21]World Health Organisation. WHO recommendations for the prevention and treatment of postpartum haemorrhage. 2012 http://apps.who.int/iris/bitstream/10665/75411/1/9789241548502_eng.pdf. [Accessed 30th October 2017]. 23586122
- Authors
- on behalf of the CRADLE Trial Collaborative Group, Vousden, N., Lawley, E., Nathan, H. L., Seed, P. T., Brown, A., Muchengwa, T., Charantimath, U., Bellad, M., Gidiri, M. F., Goudar, S., Chappell, L. C., Sandall, J., & Shennan, A. H.
- Affiliations
- King's College London (GB)
- Jawaharlal Nehru Medical College (IN)
- University of Zimbabwe (ZW)
- Corresponding author
- Vousden, Nicola
- ORCID
- Venue
- BMC Pregnancy and Childbirth
- Published
- 2018-04-27
- Volume
- 18
- Issue
- 1
- Pages
- 115-115
- ISSN
- 1471-2393 (ISSN-L)
- PMC
- PMC5924508
- OpenAlex
- W2807332232
- Cited by
- 30
- References
- 19
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 1 · 2023: 6 · 2022: 2 · 2021: 3 · 2020: 4 · 2019: 2 · 2018: 1 · 2016: 1 · 2014: 2 · 2013: 1
- FWCI
- 3.82
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- BMC Pregnancy and Childbirth (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Research Portal (King's College London) (submittedVersion, cc-by)
- UTS ePRESS (University of Technology Sydney) (submittedVersion)
- Research Explorer (The University of Manchester) (submittedVersion)
- Funders
- Medical Research Council (GB) joint funding with Department of International Health and Department of Biotechnology India (MR/N006240/1)
- Topics
- Health Sciences › Health Professions › General Health Professions › Health Policy Implementation Science
- Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Global Maternal and Child Health
- Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Maternal and fetal healthcare
- Keywords
- vital signs monitoring, maternal mortality, maternal morbidity, resource-limited settings, obstetric care, health professions education, intervention fidelity, implementation acceptability, trial feasibility, clinical decision-making
- MeSH terms
- Diagnostic Techniques, Obstetrical and Gynecological, Ethiopia, Feasibility Studies, Female, Health Personnel, Health Plan Implementation, Health Resources, Humans, India, Monitoring, Physiologic, Pregnancy, Surveys and Questionnaires, Referral and Consultation, Research Design, Zimbabwe, Randomized Controlled Trials as Topic, Focus Groups, Decision Support Systems, Clinical, Qualitative Research, Vital Signs, Maternal Death
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review