CoChat

Label-free blood serum detection by using surface-enhanced Raman spectroscopy and support vector machine for the preoperative diagnosis of parotid gland tumors

Open access

The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.

Abstract

BACKGROUND: It is difficult for the parotid gland neoplasms to make an accurate preoperative diagnosis due to the restriction of biopsy in the parotid gland neoplasms. The aim of this study is to apply the surface-enhanced Raman spectroscopy (SERS) method for the blood serum biochemical detection and use the support vector machine for the analysis in order to develop a simple but accurate blood serum detection for preoperative diagnosis of the parotid gland neoplasms. METHODS: The blood serums were collected from four groups: the patients with pleomorphic adenoma, the patients with Warthin's tumor, the patients with mucoepidermoid carcinoma and the volunteers without parotid gland neoplasms. Au nanoparticles (Au NPs) were mixed with the blood serum as the SERS active nanosensor to enhance the Raman scattering signals produced by the various biochemical materials and high quality SERS spectrum were obtained by using the Raman microscope system. Then the support vector machine was utilized to analyze the differences of the SERS spectrum from the blood serum of different groups and established a diagnostic model to discriminate the different groups. RESULTS: It was demonstrated that there were different intensities of SERS peaks assigned to various biochemical changes in the blood serum between the parotid gland tumor groups and normal control group. Compared with the SERS spectra of the normal serums, the intensities of peaks assigned to nucleic acids and proteins increased in the SERS spectra of the parotid gland tumor serums, which manifested the differences of the biochemical metabolites in the serum from the patients with parotid gland tumors. When the leave-one-sample-out method was used, support vector machine (SVM) played an outstanding performance in the classification of the SERS spectra with the high accuracy (84.1 % ~ 88.3 %), sensitivity (82.2 % ~ 97.4 %) and specificity (73.7 % ~ 86.7 %). Though the accuracy, sensitivity and specificity decreased in the leave-one-patient-out cross validation, the mucoepidermoid carcinoma was still easier to diagnose than other tumors. DISCUSSION: The specific molecular differences of parotid gland tumors and normal serums were significantly demonstrated through the comparison between the various SERS spectra.But compared with the serum SERS spectra reported in the other studies, some differences exist between the spectra in this study and the ones reported in the lietratures. These differences may result from the various nano-particles, the different preparation of serum and equipment parameters, and we could need a further research to find an exact explanation.Based on the SERS spectra of the serum samples, SVM have shown a giant potential to diagnose the parotid gland tumors in our preliminary study. However, different cross validaiton methods could effect the accuracy and a further study involing a great number of samples should be needed. CONCLUSIONS: This exploratory research demonstrated the great potential of SERS combined with SVM into a non-invasive clinical diagnostic method for preoperative diagnosis of parotid gland tumors. And the internal relation between the spectra and patients should be established in the further study.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s12885-015-1653-7

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 a The UV/visible absorption spectra of the Au NPs, serum and the mixture of Au NPs and serum. b SERS spectrum of serum, normal Raman spectrum of serum and background Raman spectrum of the Au NPs colloid. c The SEM images of Au NPs. d The SEM images of the mixture of Au NPs and serum
Fig. 1 a The UV/visible absorption spectra of the Au NPs, serum and the mixture of Au NPs and serum. b SERS spectrum of serum, normal Raman spectrum of serum and background Raman spectrum of the Au NPs colloid. c The SEM images of Au NPs. d The SEM images of the mixture of Au NPs and serumCC BY · PubMed Central
Fig. 2 The average Raman spectra of PA, WT, MEC and normal control samples. (a: The average spectrum of PA. b: The average spectrum of WT. c: The average spectrum of MEC. d: The average spectrum of normal samples). The gray areas manifest the standard deviations
Fig. 2 The average Raman spectra of PA, WT, MEC and normal control samples. (a: The average spectrum of PA. b: The average spectrum of WT. c: The average spectrum of MEC. d: The average spectrum of normal samples). The gray areas manifest the standard deviationsCC BY · PubMed Central
Fig. 3 a Comparison of the PA and normal group. b Comparison of the WT and normal group. c Comparison of the MEC and normal group
Fig. 3 a Comparison of the PA and normal group. b Comparison of the WT and normal group. c Comparison of the MEC and normal groupCC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 39 references

Research works printed but not linked: 1

  1. Gale N, Plich BZ, Sidransky D, Westra W, Califano J. World Health Organization classificaiton of tumors. In: Barnes L, Eveson JW, Reichart P, Sidransky D, editors. Pathology and genetics Head and neck tumors. Lyon: IARC Press; 2005. p. P.246.

Cited by

See all 62

Metadata

Authors
Yan, B., Li, B., Wen, Z., Luo, X., Xue, L., & Li, L.
Affiliations
  • Xiamen University (CN)
  • Sichuan University (CN)
Corresponding author
Li, Longjiang
Venue
BMC Cancer
Published
2015-10-05
Volume
15
Issue
1
Pages
650-650
ISSN
1471-2407 (ISSN-L)
OpenAlex
W1878035785
Cited by
61
References
39
Citations by year
2026: 4 · 2025: 8 · 2024: 1 · 2023: 2 · 2022: 9 · 2021: 8 · 2020: 9 · 2019: 1 · 2018: 10 · 2017: 7 · 2016: 2
FWCI
3.83
Type
journal article
Language
en
Open access
Locations
  • BMC Cancer (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Funders
  • National Natural Science Foundation of China (81172578)
  • Xiamen University
  • State Key Laboratory of Physical Chemistry of Solid Surfaces, Xiamen University
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Gold and Silver Nanoparticles Synthesis and Applications
  • Health Sciences › Medicine › Surgery › Salivary Gland Tumors Diagnosis and Treatment
Keywords
parotid gland tumors, preoperative diagnosis, surface-enhanced Raman spectroscopy, serum biomarkers, gold nanoparticles, support vector machine, pleomorphic adenoma, Warthin's tumor, mucoepidermoid carcinoma, non-invasive cancer diagnosis
MeSH terms
Adolescent, Adult, Aged, Female, Humans, Male, Middle Aged, Parotid Neoplasms, Preoperative Care, Spectrum Analysis, Raman, Biomarkers, Young Adult, Support Vector Machine

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Label-free blood serum detection by using surface-enhanced Raman spectroscopy and support vector machine for the preoperative diagnosis of parotid gland tumors. https://app.cochat.ai/papers/10.1186/s12885-015-1653-7
The paper
Yan, B., Li, B., Wen, Z., Luo, X., Xue, L., & Li, L. (2015). Label-free blood serum detection by using surface-enhanced Raman spectroscopy and support vector machine for the preoperative diagnosis of parotid gland tumors. BMC Cancer. https://doi.org/10.1186/s12885-015-1653-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.