Multi-vendor evaluation of artificial intelligence as an independent reader for double reading in breast cancer screening on 275,900 mammograms
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Background: Double reading (DR) in screening mammography increases cancer detection and lowers recall rates, but has sustainability challenges due to workforce shortages. Artificial intelligence (AI) as an independent reader (IR) in DR may provide a cost-effective solution with the potential to improve screening performance. Evidence for AI to generalise across different patient populations, screening programmes and equipment vendors, however, is still lacking. Methods: This retrospective study simulated DR with AI as an IR, using data representative of real-world deployments (275,900 cases, 177,882 participants) from four mammography equipment vendors, seven screening sites, and two countries. Non-inferiority and superiority were assessed for relevant screening metrics. Results: DR with AI, compared with human DR, showed at least non-inferior recall rate, cancer detection rate, sensitivity, specificity and positive predictive value (PPV) for each mammography vendor and site, and superior recall rate, specificity, and PPV for some. The simulation indicates that using AI would have increased arbitration rate (3.3% to 12.3%), but could have reduced human workload by 30.0% to 44.8%. Conclusions: AI has potential as an IR in the DR workflow across different screening programmes, mammography equipment and geographies, substantially reducing human reader workload while maintaining or improving standard of care. Trial registration: ISRCTN18056078 (20/03/2019; retrospectively registered).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
International evaluation of an AI system for breast cancer screening
McKinney, S. M., Sieniek, M., Godbole, V., Godwin, J., Antropova, N., Ashrafian, H., Back, T., Chesus, M., Corrado, G. S., Darzi, A., et al. (2020) · Nature · doi:10.1038/s41586-019-1799-6 · Cited by 3,287 · cited 2×
“These included small-scale reader studies [22–25, 27] and larger-scale larger-scale retrospective studies Rigorous large-scale, multi-vendor studies are needed to assess performance of AI in double reading on diverse cohorts of women across multiple screening sites and programmes, and on unenriched…”
BackgroundResultTabar, L., Yen, M.-F., Vitak, B., Chen, H.-H. T., Smith, R. A., & Duffy, S. W. (2003) · The Lancet · doi:10.1016/s0140-6736(03)13143-1 · Cited by 742
Diagnostic Accuracy of Digital Screening Mammography With and Without Computer-Aided Detection
Lehman, C. D., Wellman, R. D., Buist, D. S. M., Kerlikowske, K., Tosteson, A. N. A., & Miglioretti, D. L. (2015) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2015.5231 · Cited by 678 · cited 1×
“In the past, computer-aided detection (CAD) software have been used to automate some screening mammo-gram analysis, which has been adopted by over 83% of US facilities [18], but recent studies questioned CAD’s benefit to screening outcomes [19, 20].”
MethodLotter, W., Diab, A. R., Haslam, B., Kim, J. G., Grisot, G., Wu, E., Wu, K., Onieva, J. O., Boyer, Y., Boxerman, J. L., et al. (2021) · Nature Medicine · doi:10.1038/s41591-020-01174-9 · Cited by 423
Freeman, K., Geppert, J., Stinton, C., Todkill, D., Johnson, S., Clarke, A., & Taylor-Phillips, S. (2021) · BMJ · doi:10.1136/bmj.n1872 · Cited by 338
Radiologist shortage leaves patient care at risk, warns royal college
Rimmer, A. (2017) · BMJ · doi:10.1136/bmj.j4683 · Cited by 193
Cited by
Uses and Limitations of Artificial Intelligence for Oncology
Kolla, L., & Parikh, R. B. (2024) · Cancer · doi:10.1002/cncr.35307 · Cited by 126
de Almeida, J. G., Messiou, C., Withey, S. J., Matos, C., Koh, D.-M., & Papanikolaou, N. (2025) · European Radiology · doi:10.1007/s00330-025-11654-6 · Cited by 23
Artificial Intelligence in Clinical Oncology: From Productivity Enhancement to Creative Discovery
Kuno, M., Osumi, H., Udagawa, S., Yoshikawa, K., Ooki, A., Shinozaki, E., Ishikawa, T., Oba, J., Yamaguchi, K., & Sakurada, K. (2025) · Current Oncology · doi:10.3390/curroncol32110588 · Cited by 7
“AI models must perform consistently across all patient populations to avoid perpetuating health disparities [110–116].”
Metadata
- Authors
- Sharma, N., Ng, A. Y., James, J. J., Khara, G., Ambrózay, É., Austin, C. C., Forrai, G., Fox, G., Glocker, B., Heindl, A., Karpati, E., Rijken, T. M., Venkataraman, V., Yearsley, J. E., & Kecskemethy, P. D.
- Venue
- BMC Cancer
- Published
- 2023-05-19
- Volume
- 23
- Issue
- 1
- Pages
- 460-460
- ISSN
- 1471-2407 (ISSN-L)
- OpenAlex
- W4377097091
- Cited by
- 65
- References
- 6
- FWCI
- 5.62
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multi-vendor evaluation of artificial intelligence as an independent reader for double reading in breast cancer screening on 275,900 mammograms. https://app.cochat.ai/papers/10.1186/s12885-023-10890-7
- The paper
- Sharma, N., Ng, A. Y., James, J. J., Khara, G., Ambrózay, É., Austin, C. C., Forrai, G., Fox, G., Glocker, B., Heindl, A., Karpati, E., Rijken, T. M., Venkataraman, V., Yearsley, J. E., & Kecskemethy, P. D. (2023). Multi-vendor evaluation of artificial intelligence as an independent reader for double reading in breast cancer screening on 275,900 mammograms. BMC Cancer. https://doi.org/10.1186/s12885-023-10890-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.