Quality of EHR data extractions for studies of preterm birth in a tertiary care center: guidelines for obtaining reliable data
Open accessThe DOI matches its Crossref record.
Abstract
BACKGROUND: The use of Electronic Health Records (EHR) has increased significantly in the past 15 years. This study compares electronic vs. manual data abstractions from an EHR for accuracy. While the dataset is limited to preterm birth data, our work is generally applicable. We enumerate challenges to reliable extraction, and state guidelines to maximize reliability. METHODS: An Epic™ EHR data extraction of structured data values from 1,772 neonatal records born between the years 2001-2011 was performed. The data were directly compared to a manually-abstracted database. Specific data values important to studies of perinatology were chosen to compare discrepancies between the two databases. RESULTS: Discrepancy rates between the EHR extraction and the manual database were calculated for gestational age in weeks (2.6 %), birthweight (9.7 %), first white blood cell count (3.2 %), initial hemoglobin (11.9 %), peak total and direct bilirubin (11.4 % and 4.9 %), and patent ductus arteriosus (PDA) diagnosis (12.8 %). Using the discrepancies, errors were quantified in both datasets using chart review. The EHR extraction errors were significantly fewer than manual abstraction errors for PDA and laboratory values excluding neonates transferred from outside hospitals, but significantly greater for birth weight. Reasons for the observed errors are discussed. CONCLUSIONS: We show that an EHR not modified specifically for research purposes had discrepancy ranges comparable to a manually created database. We offer guidelines to minimize EHR extraction errors in future study designs. As EHRs become more research-friendly, electronic chart extractions should be more efficient and have lower error rates compared to manual abstractions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Shickel, B., Tighe, P. J., Bihorac, A., & Rashidi, P. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2767063 · Cited by 1,688
Clinical text data in machine learning: systematic review
Spasic, I., & Nenadic, G. (2020) · JMIR Medical Informatics · doi:10.2196/17984 · Cited by 358
Electronic Health Record Data Quality Assessment and Tools: A Systematic Review
Lewis, A. E., Weiskopf, N., Abrams, Z. B., Foraker, R., Lai, A. M., Payne, P. R. O., & Gupta, A. (2023) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocad120 · Cited by 171
Metadata
- Authors
- Knake, L. A., Ahuja, M., McDonald, E. L., Ryckman, K. K., Weathers, N., Burstain, T., Dagle, J. M., Murray, J. C., & Nadkarni, P.
- Venue
- BMC Pediatrics
- Published
- 2016-04-29
- Volume
- 16
- Issue
- 1
- Pages
- 59-59
- ISSN
- 1471-2431 (ISSN-L)
- OpenAlex
- W2345088727
- Cited by
- 45
- References
- 0
- FWCI
- 11.94
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quality of EHR data extractions for studies of preterm birth in a tertiary care center: guidelines for obtaining reliable data. https://app.cochat.ai/papers/10.1186/s12887-016-0592-z
- The paper
- Knake, L. A., Ahuja, M., McDonald, E. L., Ryckman, K. K., Weathers, N., Burstain, T., Dagle, J. M., Murray, J. C., & Nadkarni, P. (2016). Quality of EHR data extractions for studies of preterm birth in a tertiary care center: guidelines for obtaining reliable data. BMC Pediatrics. https://doi.org/10.1186/s12887-016-0592-z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.