Prolonged use of personal listening devices and hearing loss: a systematic review and meta-analysis
Open accessThe DOI matches its Crossref record; 87 of the 88 references it cites were found in a registry or an index; none of the 67 sources its claims cite is checked for support yet.
Abstract
Hearing loss affects approximately 1.5 billion people globally, with noise-induced hearing loss (NIHL) being the most preventable cause. The widespread use of personal listening devices (PLDs) has raised concerns about potential auditory damage, yet evidence remains conflicting. This systematic review and meta-analysis aimed to quantify the association between prolonged PLD use and objectively measured hearing loss. We systematically searched PubMed, Scopus, Embase, Google Scholar, Proquest, and the Cochrane Library from inception to October 2024. Studies reporting on PLD use (headphones, earphones, earbuds) and hearing outcomes (pure-tone audiometry, otoacoustic emissions) were included. Quality assessment was performed using the Joanna Briggs Institute checklists. A random-effects meta-analysis was conducted to pool odds ratios (ORs) for hearing loss among PLD users compared to non-users. Of 16,635 initial records, 8,056 unique records were screened after duplicate removal. Following title/abstract screening, 125 articles were assessed, of which 60 studies met inclusion criteria, encompassing 67,404 participants across 20 countries. The pooled OR for hearing loss among PLD users compared to non-users was 2.26 (95% CI: 1.19–4.30; p = 0.01; I²=72%). Subgroup analyses, interpreted as exploratory given limited study numbers in some strata, revealed that the association was significant in adults (OR = 2.43, 95% CI: 1.21–4.87) but not in children/adolescents (OR = 0.88, 95% CI: 0.43–1.80; p for subgroup difference = 0.05), a finding that likely reflects shorter cumulative exposure and methodological limitations rather than true safety. Earphone users showed a non-significant pooled OR of 9.09 (95% CI: 0.44–188.65; P = 0.15), and sensitivity analysis led to a revised significant pooled OR (2.60, 95% CI: 1.52–4.46; P = 0.0005); headphone users had a significant OR of 4.04 (95% CI: 1.15–14.16) based on one study. A dose-response gradient was observed for both duration (short: OR = 0.84; medium: OR = 3.20; long: OR = 4.55; p for subgroup difference = 0.07) and listening volume (low: OR = 0.81; moderate: OR = 1.70; high: OR = 9.87; p for subgroup difference < 0.0001), although the duration gradient did not reach statistical significance. Sensitivity analyses confirmed the robustness of findings, though the HKSJ-adjusted CI was wider (OR = 2.31, 95% CI: 0.89–5.97). Extended high-frequency audiometry detected subclinical damage in all 12 studies reporting these measures, and 10 of 11 otoacoustic emission studies showed significant amplitude reductions among PLD users. The certainty of evidence was rated as LOW due to serious risk of bias and inconsistency. Prolonged and high-volume PLD use is associated with 2.26-fold increased odds of objectively measured hearing loss, with clear dose-response gradients for duration and volume. However, the predominantly cross-sectional evidence precludes causal inference, and substantial unexplained heterogeneity limits precision. Subgroup findings require confirmation in larger, methodologically rigorous studies. These findings are broadly consistent with public health recommendations promoting safe listening habits, including the 60/60 rule (≤ 60% volume for ≤ 60 min/day), noise-canceling devices, and regular hearing screening for high-risk users. Future longitudinal studies with objective dosimetry are urgently needed to establish causality.
Overview
CoChat Summary
TL;DR
This systematic review and meta-analysis of 60 studies (67,404 participants, 20 countries) found that prolonged personal listening device (PLD) use was associated with 2.26-fold higher odds of objectively measured hearing loss (95% CI 1.19–4.30; p = 0.01), with dose-response gradients for listening volume and duration. The authors rate the certainty of evidence as LOW and caution that predominantly cross-sectional data preclude causal inference.
Key findings
- Pooled OR for hearing loss among PLD users vs. non-users was 2.26 (95% CI 1.19–4.30; p = 0.01; I² = 72%) across 12 cross-sectional studies; the HKSJ-adjusted sensitivity analysis gave OR = 2.31 (95% CI 0.89–5.97; p = 0.084).
- Subgroup analyses: adults (≥ 18 years) OR = 2.43 (95% CI 1.21–4.87; p = 0.01); children/adolescents (< 18 years) OR = 0.88 (95% CI 0.43–1.80; p = 0.72), with p for subgroup difference = 0.05. Earphones OR = 9.09 (95% CI 0.44–188.65; p = 0.15), revised to 2.60 (95% CI 1.52–4.46; p = 0.0005) after excluding one outlier; headphones OR = 4.04 (95% CI 1.15–14.16) from a single study.
- Dose-response gradients: duration (short OR = 0.84; medium OR = 3.20; long OR = 4.55; p for subgroup difference = 0.07) and volume (low OR = 0.81; moderate OR = 1.70; high OR = 9.87; p for subgroup difference < 0.0001).
- All 12 extended high-frequency audiometry studies found significantly worse thresholds (10–16 kHz) in PLD users despite normal conventional audiometry; 10 of 11 otoacoustic emission studies showed significant amplitude reductions. High-frequency (4–8 kHz) hearing loss prevalence was 19.4% (95% CI 14.8–24.9%). Twenty-five of 60 studies (41.7%) reported no significant association.
Methods
- Systematic review and meta-analysis (PRISMA-guided) searching PubMed/MEDLINE, Scopus, Embase, Google Scholar, ProQuest, and Cochrane Library from inception to October 2024, plus grey literature; 16,635 records identified, 8,056 unique records screened, 125 full texts assessed, 60 studies included (53 cross-sectional, 5 cohort, 2 case-control; published 1985–2024).
- Eligibility required human participants without pre-existing hearing pathology, prolonged/chronic PLD use (headphones, earphones, earbuds, MP3 players, smartphones), non-user or low-use comparators, and objective hearing outcomes (pure-tone audiometry, extended high-frequency audiometry, otoacoustic emissions); self-reported symptoms were secondary outcomes.
- Random-effects meta-analysis (DerSimonian-Laird) in RevMan 5.4 using Mantel-Haenszel odds ratios; heterogeneity by I²; prespecified subgroup analyses by age group and device type, plus duration and volume; publication bias via funnel plot and Egger's test; quality assessed with JBI checklists and certainty with GRADE.
Limitations
- Stated by the authors: substantial unexplained heterogeneity (I² = 72%) limiting precision and generalizability; 88% of included studies were cross-sectional, precluding causal inference; exposure was primarily self-reported (only five studies used objective dosimetry), introducing recall bias and misclassification; many studies did not adequately control confounders such as occupational noise, firearm use, loud concerts, hearing protection, and genetic susceptibility; the REML/HKSJ sensitivity analysis yielded a wider CI (0.89–5.97) indicating the primary estimate may overstate precision; GRADE certainty was rated LOW for all key outcomes due to serious risk of bias and inconsistency.
- Evident in the text: several subgroup estimates rest on very few studies (three for children/adolescents, three for earphones, one for headphones), and the earphone pooled estimate is dominated by a single extreme outlier (OR = 383.87); the authors themselves label these subgroup findings exploratory and requiring confirmation. The paper's limitations section also appears truncated mid-sentence ("Fifth,"), so the full list of stated limitations may be incomplete.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 48 Not checked · 113 Own results and interpretations
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Substantial heterogeneity was observed (I² = 72%; Chi² = 38.60, df = 11, p < 0.00001; Tau² = 0.81)”
§ Prolonged use of personal listening devices and hearing loss: a systematic review and meta-analysis > Results > Primary meta-analysis: odds of hearing loss in PLD users
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“36.7% (n = 22) of studies found no statistically significant association between PLD use and hearing loss.”
§ Prolonged use of personal listening devices and hearing loss: a systematic review and meta-analysis > Results > Device type
plainn = 22- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Eight studies reported tinnitus prevalence among PLD users, ranging from 9.8% to 35%.”
§ Prolonged use of personal listening devices and hearing loss: a systematic review and meta-analysis > Results > Tinnitus findings
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“but not in children/adolescents (OR = 0.88, 95% CI: 0.43–1.80; p for subgroup difference = 0.05)”
§ Prolonged use of personal listening devices and hearing loss: a systematic review and meta-analysis > Abstract > Results
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on 2 assumptions not shown here.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“and listening volume (low: OR = 0.81; moderate: OR = 1.70; high: OR = 9.87; p for subgroup difference < 0.0001)”
§ Prolonged use of personal listening devices and hearing loss: a systematic review and meta-analysis > Abstract > Results
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on 2 assumptions not shown here.
80 more claims
Create a free account to see all 161 claims and to verify the 67 references still open.
- Probably not a substantial claim. 26
- It may state two separate claims as one. 52
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Prolonged use of personal listening devices and hearing loss: a systematic review and meta-analysis > Results > Device type
“36.7% (n = 22) of studies found no statistically significant association between PLD use and hearing loss.”
§ Prolonged use of personal listening devices and hearing loss: a systematic review and meta-analysis > Results > Studies reporting no significant association
“Twenty-five of 60 studies (41.7%) reported no statistically significant association.”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Prolonged use of personal listening devices and hearing loss: a systematic review and meta-analysis > Results > Publication bias
“Trim-and-fill analysis imputed three potentially missing studies, resulting in an adjusted pooled OR of 2.48 (95% CI: 1.73–3.55)”
§ Prolonged use of personal listening devices and hearing loss: a systematic review and meta-analysis > Results > Certainty of evidence (GRADE) and recommendations
“cEgger’s test p = 0.12; trim-and-fill adjustment (OR = 2.26) did not change conclusion”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Prolonged use of personal listening devices and hearing loss: a systematic review and meta-analysis > Results > Subgroup analyses
“Children and adolescents (< 18 years): Three studies [61, 70, 79])”
§ Prolonged use of personal listening devices and hearing loss: a systematic review and meta-analysis > Results > Subgroup analyses
“Adults (≥ 18 years): Eight studies [3, 77, 97, 11, 81, 61, 89, 70]”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Prolonged use of personal listening devices and hearing loss: a systematic review and meta-analysis > Results > Listening volume
“The test for subgroup differences was statistically significant (χ²=22.52, df = 3, p < 0.0001, I²=86.7%)”
§ Prolonged use of personal listening devices and hearing loss: a systematic review and meta-analysis > Results > Listening volume
“Studies were categorized as low volume (< 75 dBA or < 60% of maximum), moderate volume (75–85 dBA or 60–75% of maximum), and high volume (> 85 dBA or > 75% of maximum).”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Prolonged use of personal listening devices and hearing loss: a systematic review and meta-analysis > Results > Quality assessment
“Among the five cohort/experimental studies, quality scores ranged from 7 to 10 out of 11 JBI criteria.”
§ Prolonged use of personal listening devices and hearing loss: a systematic review and meta-analysis > Results > Quality assessment
“| Naik (2024) [85] | Yes | Yes | No | No | No | No | Yes | Yes | Unclear | No | No |”
5 more findings
Create a free account to see every finding of this check.
Citations
Cites
The PRISMA 2020 statement: An updated guideline for reporting systematic reviews
Page, M. J., McKenzie, J. E., Bossuyt, P. M., Boutron, I., Hoffmann, T. C., Mulrow, C. D., Shamseer, L., Tetzlaff, J. M., Akl, E. A., Brennan, S. E., et al. (2021) · BMJ · doi:10.1136/bmj.n71 · Cited by 108,283
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552
GRADE: an emerging consensus on rating quality of evidence and strength of recommendations
Guyatt, G. H., Oxman, A. D., Vist, G. E., Kunz, R., Falck-Ytter, Y., Alonso-Coello, P., & Schünemann, H. J. (2008) · BMJ · doi:10.1136/bmj.39489.470347.ad · Cited by 23,305
Auditory and non-auditory effects of noise on health
Basner, M., Babisch, W., Davis, A., Brink, M., Clark, C., Janssen, S., & Stansfeld, S. (2014) · The Lancet · doi:10.1016/s0140-6736(13)61613-x · Cited by 2,473
The Role of Oxidative Stress in Noise-Induced Hearing Loss
Henderson, D., Bielefeld, E. C., Harris, K. C., & Hu, B. H. (2006) · Ear & Hearing · doi:10.1097/01.aud.0000191942.36672.f3 · Cited by 879
Cochlear synaptopathy in acquired sensorineural hearing loss: Manifestations and mechanisms
Liberman, M. C., & Kujawa, S. G. (2017) · Hearing Research · doi:10.1016/j.heares.2017.01.003 · Cited by 706
Does noise affect learning? A short review on noise effects on cognitive performance in children
Klatte, M., Bergström, K., & Lachmann, T. (2013) · Frontiers in Psychology · doi:10.3389/fpsyg.2013.00578 · Cited by 446
Niskar, A. S., Kieszak, S. M., Holmes, A. E., Esteban, E., Rubin, C., & Brody, D. J. (2001) · Pediatrics · doi:10.1542/peds.108.1.40 · Cited by 415
Aging and Hearing Health: The Life-course Approach
Davis, A., McMahon, C. M., Pichora-Fuller, K. M., Russ, S., Lin, F., Olusanya, B. O., Chadha, S., & Tremblay, K. L. (2016) · The Gerontologist · doi:10.1093/geront/gnw033 · Cited by 402
Cellular mechanisms of noise-induced hearing loss
Kurabi, A., Keithley, E. M., Housley, G. D., Ryan, A. F., & Wong, A. C.-Y. (2017) · Hearing Research · doi:10.1016/j.heares.2016.11.013 · Cited by 360
Research works printed but not linked: 9
- Agustiawan. Description of use of personal listening devices (PLD) during online learning during covid-19 pandemic. Health Saf Environ J. 2021;2(2):1–4.
- Moola S, Munn Z, Tufanaru C, Aromataris E, Sears K, Sfetcu R, et al. Chapter 7: Systematic reviews of etiology and risk. In: Aromataris E, Munn Z, editors. JBI Manual for Evidence Synthesis. Adelaide: JBI; 2020.
- George N, Britto R, R D. Effect of pure tone audiometry among young adults using earphones. Int J Acad Med Pharm. 2023;5:1328–32.
- Shruthi HS, Shilpa R, Nisha K. Evaluation of hearing loss in medical students using electronic auditory gadgets - A subjective and objective assessment. Int J Pharm Clin Res. 2024;16(9):998–1004. Available from: https://ijpcr.com/volume16issue9/.
- Rafique F, Khan G, Sultan H, Zaman S, Mushtaq F, IkramA. Effects of MP3 use on hearing threshold in young adults. Rawal Med J. 2022;47(4):956–9.
- Hodgson M, Li W. A study of the variation in output levels of personal music players in different listening environments. Can Acoust. 2008;36(3):22–8.
- Rothman KJ, Greenland S, Lash TL. Modern epidemiology. 3rd ed. Philadelphia: Lippincott Williams & Wilkins; 2008.
- World Health Organization. Make Listening Safe. Geneva: World Health Organization; 2015.
- European Commission. Standard for personal music players: EN 50332. Brussels: European Committee for Electrotechnical Standardization; 2013.
Cited by
Still being checked.
Metadata
- Authors
- Golshaniniya, P., PorkarKhatibi, M., Rouhi, A. J., Moghaddam, Y. J., Zabet, S., Salehi-Pourmehr, H., & Shahsavarinia, K.
- Affiliations
- Tabriz University of Medical Sciences (IR)
- Corresponding author
- Shahsavarinia, Kavous
- ORCID
- Venue
- BMC Public Health
- Published
- 2026-08-31
- Volume
- 26
- Issue
- 1
- Pages
- 3505
- ISSN
- 1471-2458 (ISSN-L)
- PMC
- PMC13791535
- OpenAlex
- W7204826746
- Cited by
- 0
- References
- 85
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-nc-nd
- creativecommons.org/licenses/by-nc-nd/4.0 (tdm)
- creativecommons.org/licenses/by-nc-nd/4.0 (vor, 84 d)
- Locations
- BMC Public Health (publishedVersion, cc-by-nc-nd)
- Topics
- Life Sciences › Neuroscience › Sensory Systems › Hearing, Cochlea, Tinnitus, Genetics
- Health Sciences › Health Professions › Speech and Hearing › Hearing Loss and Rehabilitation
- Physical Sciences › Physics and Astronomy › Acoustics and Ultrasonics › Noise Effects and Management
- Keywords
- personal listening devices, noise-induced hearing loss, hearing loss, headphones, earphones, earbuds, otoacoustic emissions, pure tone audiometry, cumulative noise exposure, children and adolescents, dose-response relationship, hearing protection, earplugs, noise-induced tinnitus, hearing loss prevention
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-24, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-24 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prolonged use of personal listening devices and hearing loss: a systematic review and meta-analysis. https://app.cochat.ai/papers/10.1186/s12889-026-29110-5
- The paper
- Golshaniniya, P., PorkarKhatibi, M., Rouhi, A. J., Moghaddam, Y. J., Zabet, S., Salehi-Pourmehr, H., & Shahsavarinia, K. (2026). Prolonged use of personal listening devices and hearing loss: a systematic review and meta-analysis. BMC Public Health. https://doi.org/10.1186/s12889-026-29110-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.