The DOI matches its Crossref record.
Diagnostic yield and risk/benefit analysis of trans-bronchial lung cryobiopsy in diffuse parenchymal lung diseases: a large cohort of 699 patients
Open accessAbstract
BACKGROUND: Standardization of trans-bronchial lung cryobiopsy in diffuse parenchymal lung diseases is imminent; however, the majority of published series on cryobiopsy include a limited number of patients and are characterized by several differences in procedural technical details. METHODS: This is an observational, retrospective cohort study. Aim of the study was to suggest some sampling strategies related to transbronchial cryobiopsy in the diagnostic work-up of patients with diffuse parenchymal lung diseases. RESULTS: Six hundred ninety-nine patients with suspected diffuse parenchymal lung disease were recruited. A specific pathological diagnosis was achieved in 614/699 cases (87.8%) and a multidisciplinary diagnosis was obtained in 630/699 cases (90.1%). Diagnostic yield was significantly influenced by the number of samples taken (1 vs ≥ 2 biopsies, p < 0.005). In 60.4% of patients, biopsies were taken from one site and in 39.6% from different sites (in the same lobe or in two different lobes), with a significant increase in diagnostic yield, specifically in patients with fibrotic lung diseases (65.5% vs 93.4%, p < 0.0001). The 2.4 mm or 1.9 mm probes were used, with no differences in terms of diagnostic yield. Regarding safety, pneumothorax occurred in 19.2% and was influenced by baseline lung function; in all patients Fogarty balloon has been used and severe haemorrhage occurred in 0.7% of cases. Three patients (0.4% of cases) died within 30 days after the procedure. CONCLUSIONS: We propose some sampling strategies of cryobiopsy which seem to be associated with a higher diagnostic yield and a favorable risk/benefit ratio: sampling at least two samples in different sites, using either the 2.4 mm or the 1.9 mm probe, intubating the patients and using bronchial blockers/catheters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Raghu, G., Remy-Jardin, M., Richeldi, L., Thomson, C. C., Inoue, Y., Johkoh, T., Kreuter, M., Lynch, D. A., Maher, T. M., Martinez, F. J., et al. (2022) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.202202-0399st · Cited by 2,957
Self-citationRaghu, G., Remy-Jardin, M., Ryerson, C. J., Myers, J. L., Kreuter, M., Vasakova, M., Bargagli, E., Chung, J. H., Collins, B. F., Bendstrup, E., et al. (2020) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.202005-2032st · Cited by 1,047
Metadata
- Authors
- Ravaglia, C., Wells, A. U., Tomassetti, S., Gurioli, C., Gurioli, C., Dubini, A., Cavazza, A., Colby, T. V., Piciucchi, S., Puglisi, S., Bosi, M., & Poletti, V.
- Venue
- BMC Pulmonary Medicine
- Published
- 2019-01-16
- Volume
- 19
- Issue
- 1
- Pages
- 16-16
- ISSN
- 1471-2466 (ISSN-L)
- OpenAlex
- W2916465534
- Cited by
- 205
- References
- 0
- FWCI
- 21.91
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnostic yield and risk/benefit analysis of trans-bronchial lung cryobiopsy in diffuse parenchymal lung diseases: a large cohort of 699 patients. https://app.cochat.ai/papers/10.1186/s12890-019-0780-3
- The paper
- Ravaglia, C., Wells, A. U., Tomassetti, S., Gurioli, C., Gurioli, C., Dubini, A., Cavazza, A., Colby, T. V., Piciucchi, S., Puglisi, S., Bosi, M., & Poletti, V. (2019). Diagnostic yield and risk/benefit analysis of trans-bronchial lung cryobiopsy in diffuse parenchymal lung diseases: a large cohort of 699 patients. BMC Pulmonary Medicine. https://doi.org/10.1186/s12890-019-0780-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.