Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.

Inter- and intra-rater reliability for measurement of range of motion in joints included in three hypermobility assessment methods

Open access

Abstract

BACKGROUND: Comparisons across studies of generalized joint hypermobility are often difficult since there are several classification methods and methodological differences in the performance exist. The Beighton score is most commonly used and has been tested for inter- and intra-rater reliability. The Contompasis score and the Hospital del Mar criteria have not yet been evaluated for reliability. The aim of this study was to investigate the inter- and intra-rater reliability for measurements of range of motion in joints included in these three hypermobility assessment methods using a structured protocol. METHODS: The study was planned in accordance with guidelines for reporting reliability studies. Healthy adults were consecutively recruited (49 for inter- and 29 for intra-rater assessments). Intra-class correlations, two-way random effects model, (ICC 2.1) with 95% confidence intervals, standard error of measurement, percentage of agreement, Cohen's Kappa (κ) and prevalence-adjusted bias-adjusted kappa were calculated for single-joint measured in degrees and for total scores. RESULTS: The inter- and intra-rater reliability in total scores were ICC 2.1: 0.72-0.82 and 0.76-0.86 and for single-joint measurements in degrees 0.44-0.91 and 0.44-0.90, respectively. The difference between ratings was within 5 degrees in all but one joint. Standard error of measurement ranged from 1.0 to 6.9 degrees. The inter- and intra-rater reliability for prevalence of positive hypermobility findings the Cohen's κ for total scores were 0.54-0.78 and 0.27-0.78 and in single joints 0.21-1.00 and 0.19-1.00, respectively. The prevalence- and bias adjusted Cohen's κ, increased all but two values. CONCLUSIONS: Following a structured protocol, the inter- and intra-rater reliability was good-to-excellent for total scores and in all but two single joints, measured in degrees. The inter- and intra-rater reliability for prevalence of positive hypermobility findings was fair-to-almost perfect for total scores and slight-to-almost-perfect in single joints. By using a structured protocol, we attempted to standardize the assessment of range of motion in clinical and in research settings. This standardization could be helpful in the first part of the process of standardizing the tests thus avoiding that assessment of GJH is based on chance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s12891-018-2290-5

Cites

49 of 49 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 49 references

Cited by

See all 35

Metadata

Authors
Schlager, A., Ahlqvist, K., Rasmussen-Barr, E., Bjelland, E. K., Pingel, R., Olsson, C., Nilsson-Wikmar, L., & Kristiansson, P.
Affiliations
  • Uppsala University (SE)
  • Karolinska Institutet (SE)
  • Region Stockholm (SE)
Corresponding author
Schlager, Angela
Venue
BMC Musculoskeletal Disorders
Published
2018-10-17
Volume
19
Issue
1
Pages
376-376
ISSN
1471-2474 (ISSN-L)
OpenAlex
W2895824261
Cited by
35
References
49
Citations by year
2026: 2 · 2025: 4 · 2024: 4 · 2023: 7 · 2022: 5 · 2021: 8 · 2020: 3 · 2019: 2
FWCI
1.99
Type
journal article
Language
en
Open access
Licence
  • cc-by
  • creativecommons.org/licenses/by/4.0/ (tdm)
Locations
  • BMC Musculoskeletal Disorders (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, other-oa)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • KTH Publication Database DiVA (KTH Royal Institute of Technology) (submittedVersion, other-oa)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • NORA - Norwegian Open Research Archives (submittedVersion, other-oa)
  • NORA - Norwegian Open Research Archives (submittedVersion, cc-by)
Funders
Region Uppsala
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Connective tissue disorders research
  • Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
  • Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Musculoskeletal pain and rehabilitation
Keywords
generalized joint hypermobility, range of motion, inter-rater reliability, intra-rater reliability, Beighton score, measurement standardization, standard error of measurement, intra-class correlation, healthy adults, test-retest reliability
MeSH terms
Adult, Female, Humans, Joint Instability, Joints, Male, Middle Aged, Reproducibility of Results, Observer Variation, Range of Motion, Articular, Arthrometry, Articular, Young Adult, Healthy Volunteers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Inter- and intra-rater reliability for measurement of range of motion in joints included in three hypermobility assessment methods. https://app.cochat.ai/papers/10.1186/s12891-018-2290-5
The paper
Schlager, A., Ahlqvist, K., Rasmussen-Barr, E., Bjelland, E. K., Pingel, R., Olsson, C., Nilsson-Wikmar, L., & Kristiansson, P. (2018). Inter- and intra-rater reliability for measurement of range of motion in joints included in three hypermobility assessment methods. BMC Musculoskeletal Disorders. https://doi.org/10.1186/s12891-018-2290-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.