CoChat

Data mining EEG signals in depression for their diagnostic value

Open access
Mohammadi, Mahdi, Al-Azab, Fadwa, Raahemi, Bijan, Richards, Gregory, Jaworska, Natalia, Smith, Dylan, de la Salle, Sara, Blier, Pierre, Knott, Verner · 2015 · BMC Medical Informatics and Decision Making
Cited by 111

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Quantitative electroencephalogram (EEG) is one neuroimaging technique that has been shown to differentiate patients with major depressive disorder (MDD) and non-depressed healthy volunteers (HV) at the group-level, but its diagnostic potential for detecting differences at the individual level has yet to be realized. Quantitative EEGs produce complex data sets derived from digitally analyzed electrical activity at different frequency bands, at multiple electrode locations, and under different vigilance (eyes open vs. closed) states, resulting in potential feature patterns which may be diagnostically useful, but detectable only with advanced mathematical models. METHODS: This paper uses a data mining methodology for classifying EEGs of 53 MDD patients and 43 HVs. This included: (a) pre-processing the data, including cleaning and normalization, applying Linear Discriminant Analysis (LDA) to map the features into a new feature space; and applying Genetic Algorithm (GA) to identify the most significant features; (b) building predictive models using the Decision Tree (DT) algorithm to discover rules and hidden patterns based on the reduced and mapped features; and (c) evaluating the models based on the accuracy and false positive values on the EEG data of MDD and HV participants. Two categories of experiments were performed. The first experiment analyzed each frequency band individually, while the second experiment analyzed the bands together. RESULTS: Application of LDA and GA markedly reduced the total number of utilized features by ≥ 50 % and, with all frequency bands analyzed together, the model showed average classification accuracy (MDD vs. HV) of 80 %. The best results from model testing with additional test EEG recordings from 9 MDD patients and 35 HV individuals demonstrated an accuracy of 80 % and showed an average sensitivity of 70 %, a specificity of 76 %, and a positive (PPV) and negative predictive value (NPV) of 74 and 75 %, respectively. CONCLUSIONS: These initial findings suggest that the proposed automated EEG analytical approach could be a useful adjunctive diagnostic approach in clinical practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s12911-015-0227-6

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 111

Metadata

Authors
Mohammadi, M., Al-Azab, F., Raahemi, B., Richards, G., Jaworska, N., Smith, D., de la Salle, S., Blier, P., & Knott, V.
Venue
BMC Medical Informatics and Decision Making
Published
2015-12
Volume
15
Issue
1
Pages
108-108
ISSN
1472-6947 (ISSN-L)
OpenAlex
W2208039604
Cited by
111
References
8
FWCI
2.21
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Data mining EEG signals in depression for their diagnostic value. https://app.cochat.ai/papers/10.1186/s12911-015-0227-6
The paper
Mohammadi, M., Al-Azab, F., Raahemi, B., Richards, G., Jaworska, N., Smith, D., de la Salle, S., Blier, P., & Knott, V. (2015). Data mining EEG signals in depression for their diagnostic value. BMC Medical Informatics and Decision Making. https://doi.org/10.1186/s12911-015-0227-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.