The validity of synthetic clinical data: a validation study of a leading synthetic data generator (Synthea) using clinical quality measures
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Clinical data synthesis aims at generating realistic data for healthcare research, system implementation and training. It protects patient confidentiality, deepens our understanding of the complexity in healthcare, and is a promising tool for situations where real world data is difficult to obtain or unnecessary. However, its validity has not been fully examined, and no previous study has validated it from the perspective of healthcare quality, a critical aspect of a healthcare system. This study fills this gap by calculating clinical quality measures using synthetic data. METHODS: We examined an open-source well-documented synthetic data generator Synthea, which was composed of the key advancements in this emerging technique. We selected a representative 1.2-million Massachusetts patient cohort generated by Synthea. Four quality measures, Colorectal Cancer Screening, Chronic Obstructive Pulmonary Disease (COPD) 30-Day Mortality, Rate of Complications after Hip/Knee Replacement, and Controlling High Blood Pressure, were selected based on clinical significance. Calculated rates were then compared with publicly reported rates based on real-world data of Massachusetts and United States. RESULTS: Of the total Synthea Massachusetts population (n = 1,193,439), 394,476 were eligible for the "colorectal cancer screening" quality measure, and 248,433 (63%) were considered compliant, compared to the publicly reported Massachusetts and national rates being 77.3 and 69.8%, respectively. Of the 409 eligible patients, 0.7% of died within 30 days after COPD exacerbation, versus 7% reported in Massachusetts and 8% nationally. Using an expanded logic, this rate increased to 5.7%. No Synthea residents had complications after Hip/Knee Replacement (Massachusetts: 2.9%, national: 2.8%) or had their blood pressure controlled after being diagnosed with hypertension (Massachusetts: 74.52%, national: 69.7%). Results show that Synthea is quite reliable in modeling demographics and probabilities of services being offered in an average healthcare setting. However, its capabilities to model heterogeneous health outcomes post services are limited. CONCLUSIONS: Synthea and other synthetic patient generators do not currently model for deviations in care and the potential outcomes that may result from care deviations. To output a more realistic data set, we propose that synthetic data generators should consider important quality measures in their logic and model when clinicians may deviate from standard practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Triple Aim: Care, Health, And Cost
Berwick, D. M., Nolan, T. W., & Whittington, J. (2008) · Health Affairs · doi:10.1377/hlthaff.27.3.759 · Cited by 5,136 · cited 1×
“Because quality of care is one of the primary goals and characteristics of a healthcare system [8], we consider it critically important to have synthetic data presenting the same level of care quality as real data.”
BackgroundThe challenge of complexity in health care
Plsek, P. E., & Greenhalgh, T. (2001) · BMJ · doi:10.1136/bmj.323.7313.625 · Cited by 2,578
Cited by
Synthetic data in machine learning for medicine and healthcare
Chen, R. J., Lu, M. Y., Chen, T. Y., Williamson, D. F. K., & Mahmood, F. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00751-8 · Cited by 728
The National COVID Cohort Collaborative (N3C): Rationale, design, infrastructure, and deployment
Haendel, M. A., Chute, C. G., Bennett, T. D., Eichmann, D. A., Guinney, J., Kibbe, W. A., Payne, P. R. O., Pfaff, E. R., Robinson, P. N., Saltz, J. H., et al. (2021) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocaa196 · Cited by 553
Generation and evaluation of synthetic patient data
Goncalves, A., Ray, P., Soper, B., Stevens, J., Coyle, L., & Sales, A. P. (2020) · BMC Medical Research Methodology · doi:10.1186/s12874-020-00977-1 · Cited by 388
Synthetic data in health care: A narrative review
Gonzales, A., Guruswamy, G., & Smith, S. R. (2023) · PLOS Digital Health · doi:10.1371/journal.pdig.0000082 · Cited by 308
Challenges and opportunities beyond structured data in analysis of electronic health records
Tayefi, M., Ngo, P., Chomutare, T., Dalianis, H., Salvi, E., Budrionis, A., & Godtliebsen, F. (2021) · WIREs Computational Statistics · doi:10.1002/wics.1549 · Cited by 290
Metadata
- Authors
- Chen, J., Chun, D., Patel, M., Chiang, E., & James, J.
- Venue
- BMC Medical Informatics and Decision Making
- Published
- 2019-03-14
- Volume
- 19
- Issue
- 1
- Pages
- 44-44
- ISSN
- 1472-6947 (ISSN-L)
- OpenAlex
- W2928613965
- Cited by
- 110
- References
- 2
- FWCI
- 12.04
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The validity of synthetic clinical data: a validation study of a leading synthetic data generator (Synthea) using clinical quality measures. https://app.cochat.ai/papers/10.1186/s12911-019-0793-0
- The paper
- Chen, J., Chun, D., Patel, M., Chiang, E., & James, J. (2019). The validity of synthetic clinical data: a validation study of a leading synthetic data generator (Synthea) using clinical quality measures. BMC Medical Informatics and Decision Making. https://doi.org/10.1186/s12911-019-0793-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.