CoChat

Exhaled particles and small airways

Open access
Bake, B., Larsson, P., Ljungkvist, G., Ljungström, E., Olin, A-C · 2019 · Respiratory Research

The DOI matches its Crossref record; the references it cites are not checked yet.

Abstract

BACKGROUND: Originally, studies on exhaled droplets explored properties of airborne transmission of infectious diseases. More recently, the interest focuses on properties of exhaled droplets as biomarkers, enabled by the development of technical equipment and methods for chemical analysis. Because exhaled droplets contain nonvolatile substances, particles is the physical designation. This review aims to outline the development in the area of exhaled particles, particularly regarding biomarkers and the connection with small airways, i e airways with an internal diameter < 2 mm. MAIN BODY: Generation mechanisms, sites of origin, number concentrations of exhaled particles and the content of nonvolatile substances are studied. Exhaled particles range in diameter from 0.01 and 1000 μm depending on generation mechanism and site of origin. Airway reopening is one scientifically substantiated particle generation mechanism. During deep expirations, small airways close and the reopening process produces minute particles. When exhaled, these particles have a diameter of < 4 μm. A size discriminating sampling of particles < 4 μm and determination of the size distribution, allows exhaled particle mass to be estimated. The median mass is represented by particles in the size range of 0.7 to 1.0 μm. Half an hour of repeated deep expirations result in samples in the order of nanogram to microgram. The source of these samples is the respiratory tract ling fluid of small airways and consists of lipids and proteins, similarly to surfactant. Early clinical studies of e g chronic obstructive pulmonary disease and asthma, reported altered particle formation and particle composition. CONCLUSION: The physical properties and content of exhaled particles generated by the airway reopening mechanism offers an exciting noninvasive way to obtain samples from the respiratory tract lining fluid of small airways. The biomarker potential is only at the beginning to be explored.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s12931-019-0970-9

Cites

Statistics

Figures

Fig. 1 The Expiratory Droplet Investigation System setup used by Morawska et al. [21]. Test participants exhaled into a particle- free wind tunnel. A fan maintained at approximately 0.1 m/s controls the wind tunnel airflow. The airflow transports exhaled particles downstream to the aerodynamic particle sizer (APS) where the particles are measured. A relative humidity (RH) probe monitors the humidity. Reprinted from the original article by permission
Fig. 1 The Expiratory Droplet Investigation System setup used by Morawska et al. [21]. Test participants exhaled into a particle- free wind tunnel. A fan maintained at approximately 0.1 m/s controls the wind tunnel airflow. The airflow transports exhaled particles downstream to the aerodynamic particle sizer (APS) where the particles are measured. A relative humidity (RH) probe monitors the humidity. Reprinted from the original article by permissionCC BY · PubMed Central
Fig. 2 At low specified flow rates the participants exhaled to (a) residual volume (RV), (b) closing point (CP), i.e., the lung volume at which extensive airway closure begins, or (c) normal tidal exhalation to functional residual capacity (FRC). Participants then inhaled to total lung capacity (TLC) and immediately exhaled into the equipment back to FRC. By permission of the author
Fig. 2 At low specified flow rates the participants exhaled to (a) residual volume (RV), (b) closing point (CP), i.e., the lung volume at which extensive airway closure begins, or (c) normal tidal exhalation to functional residual capacity (FRC). Participants then inhaled to total lung capacity (TLC) and immediately exhaled into the equipment back to FRC. By permission of the authorCC BY · PubMed Central
Fig. 3 Schematic presentation of the equipment Almstrand et al. [22]. Participants inhale thorough a HEPA filter and exhale into the equipment. The box containing the equipment was maintained at approximately 36 °C. An optical particle sizer and an impactor allowed for counting and sampling of exhaled particles. Exhaled air that was not directly drawn into the impactor and counter was buffered in a reservoir and subsequently drawn into the impactor and counter and replaced by humidified particle-free air. Particles < 4.6 μm were sampled and the size distribution determined. By permission of the author
Fig. 3 Schematic presentation of the equipment Almstrand et al. [22]. Participants inhale thorough a HEPA filter and exhale into the equipment. The box containing the equipment was maintained at approximately 36 °C. An optical particle sizer and an impactor allowed for counting and sampling of exhaled particles. Exhaled air that was not directly drawn into the impactor and counter was buffered in a reservoir and subsequently drawn into the impactor and counter and replaced by humidified particle-free air. Particles < 4.6 μm were sampled and the size distribution determined. By permission of the authorCC BY · PubMed Central
Fig. 4 Schematic illustration of the airway reopening concept. When airways close, opposing airway walls get in contact creating a plug of respiratory tract lining fluid. As the airway walls distend during inspiration, forming a meniscus that finally breaks and generate particles. By permission of the author
Fig. 4 Schematic illustration of the airway reopening concept. When airways close, opposing airway walls get in contact creating a plug of respiratory tract lining fluid. As the airway walls distend during inspiration, forming a meniscus that finally breaks and generate particles. By permission of the authorCC BY · PubMed Central
Fig. 5 DPPC (1,2-dipalmitoyl-sn-glycero-3-phosphocholine) mass and exhaled sampled particle mass as determined in samples from eleven individuals that performed ten exhalations using the airway reopening maneuver. Note the linear association through the origin between the collected particle mass and collected DPPC mass. The DPPC weight percent concentration (wt%) is shown for each sample in the lower panel. By permission of the author
Fig. 5 DPPC (1,2-dipalmitoyl-sn-glycero-3-phosphocholine) mass and exhaled sampled particle mass as determined in samples from eleven individuals that performed ten exhalations using the airway reopening maneuver. Note the linear association through the origin between the collected particle mass and collected DPPC mass. The DPPC weight percent concentration (wt%) is shown for each sample in the lower panel. By permission of the authorCC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

The citation lists are queued

They are fetched later and appear here then.

References 53 · Cited by 218

Metadata

Authors
Bake, B., Larsson, P., Ljungkvist, G., Ljungström, E., & Olin, A.-C.
Affiliations
University of Gothenburg (SE)
Corresponding author
Olin, A-C
Venue
Respiratory Research
Published
2019-01-11
Volume
20
Issue
1
Pages
8-8
ISSN
  • 1465-9921 (ISSN-L)
  • 1465-993X
OpenAlex
W2919269222
Cited by
218
References
53
Citations by year
2026: 11 · 2025: 23 · 2024: 22 · 2023: 19 · 2022: 44 · 2021: 53 · 2020: 41 · 2019: 5
FWCI
2.92
Type
journal article
Language
en
Open access
Licence
  • cc-by
  • creativecommons.org/licenses/by/4.0/ (tdm)
Locations
  • Respiratory Research (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, other-oa)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Funders
  • Svenska Forskningsrådet Formas (2013-805)
  • Stiftelsen för Strategisk Forskning (ChAMP-consortium)
  • Hjärt-Lungfonden
  • Forskningsrådet om Hälsa, Arbetsliv och Välfärd (00419)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Chemical Sensor Technologies
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Inhalation and Respiratory Drug Delivery
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Extracellular vesicles in disease
Keywords
exhaled particles, small airways, airway reopening, respiratory tract lining fluid, exhaled droplets, biomarkers, particle size distribution, surfactants, chronic obstructive pulmonary disease, asthma
MeSH terms
Animals, Humans, Particle Size, Pulmonary Surfactants, Respiration Disorders, Surface-Active Agents, Biomarkers, Exhalation, Airway Remodeling

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Exhaled particles and small airways. https://app.cochat.ai/papers/10.1186/s12931-019-0970-9
The paper
Bake, B., Larsson, P., Ljungkvist, G., Ljungström, E., & Olin, A.-C. (2019). Exhaled particles and small airways. Respiratory Research. https://doi.org/10.1186/s12931-019-0970-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.