Exhaled particles and small airways
Open accessThe DOI matches its Crossref record; the references it cites are not checked yet.
Abstract
BACKGROUND: Originally, studies on exhaled droplets explored properties of airborne transmission of infectious diseases. More recently, the interest focuses on properties of exhaled droplets as biomarkers, enabled by the development of technical equipment and methods for chemical analysis. Because exhaled droplets contain nonvolatile substances, particles is the physical designation. This review aims to outline the development in the area of exhaled particles, particularly regarding biomarkers and the connection with small airways, i e airways with an internal diameter < 2 mm. MAIN BODY: Generation mechanisms, sites of origin, number concentrations of exhaled particles and the content of nonvolatile substances are studied. Exhaled particles range in diameter from 0.01 and 1000 μm depending on generation mechanism and site of origin. Airway reopening is one scientifically substantiated particle generation mechanism. During deep expirations, small airways close and the reopening process produces minute particles. When exhaled, these particles have a diameter of < 4 μm. A size discriminating sampling of particles < 4 μm and determination of the size distribution, allows exhaled particle mass to be estimated. The median mass is represented by particles in the size range of 0.7 to 1.0 μm. Half an hour of repeated deep expirations result in samples in the order of nanogram to microgram. The source of these samples is the respiratory tract ling fluid of small airways and consists of lipids and proteins, similarly to surfactant. Early clinical studies of e g chronic obstructive pulmonary disease and asthma, reported altered particle formation and particle composition. CONCLUSION: The physical properties and content of exhaled particles generated by the airway reopening mechanism offers an exciting noninvasive way to obtain samples from the respiratory tract lining fluid of small airways. The biomarker potential is only at the beginning to be explored.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
![Fig. 1 The Expiratory Droplet Investigation System setup used by Morawska et al. [21]. Test participants exhaled into a particle- free wind tunnel. A fan maintained at approximately 0.1 m/s controls the wind tunnel airflow. The airflow transports exhaled particles downstream to the aerodynamic particle sizer (APS) where the particles are measured. A relative humidity (RH) probe monitors the humidity. Reprinted from the original article by permission](https://figures.cochat.ai/paper-figures/bb3b0e7e12534c7ab02dbaaadc99c63f/exhaled-particles-and-small-airways-figure-1.jpg)

![Fig. 3 Schematic presentation of the equipment Almstrand et al. [22]. Participants inhale thorough a HEPA filter and exhale into the equipment. The box containing the equipment was maintained at approximately 36 °C. An optical particle sizer and an impactor allowed for counting and sampling of exhaled particles. Exhaled air that was not directly drawn into the impactor and counter was buffered in a reservoir and subsequently drawn into the impactor and counter and replaced by humidified particle-free air. Particles < 4.6 μm were sampled and the size distribution determined. By permission of the author](https://figures.cochat.ai/paper-figures/50b04d7ef4dc44af9c3d0cf0a36446cc/exhaled-particles-and-small-airways-figure-3.jpg)


Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Particles in exhaled breath are typically <4 μm with a median 0.7 to 1.0 μm [17].”
From The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage (2021) · cites this paper as [17]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
The citation lists are queued
They are fetched later and appear here then.
References 53 · Cited by 218
Metadata
- Authors
- Bake, B., Larsson, P., Ljungkvist, G., Ljungström, E., & Olin, A.-C.
- Affiliations
- University of Gothenburg (SE)
- Corresponding author
- Olin, A-C
- Venue
- Respiratory Research
- Published
- 2019-01-11
- Volume
- 20
- Issue
- 1
- Pages
- 8-8
- ISSN
- 1465-9921 (ISSN-L)
- 1465-993X
- PMC
- PMC6330423
- OpenAlex
- W2919269222
- Cited by
- 218
- References
- 53
- Citations by year
- 2026: 11 · 2025: 23 · 2024: 22 · 2023: 19 · 2022: 44 · 2021: 53 · 2020: 41 · 2019: 5
- FWCI
- 2.92
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0/ (tdm)
- Locations
- Respiratory Research (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, other-oa)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- Svenska Forskningsrådet Formas (2013-805)
- Stiftelsen för Strategisk Forskning (ChAMP-consortium)
- Hjärt-Lungfonden
- Forskningsrådet om Hälsa, Arbetsliv och Välfärd (00419)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Chemical Sensor Technologies
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Inhalation and Respiratory Drug Delivery
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Extracellular vesicles in disease
- Keywords
- exhaled particles, small airways, airway reopening, respiratory tract lining fluid, exhaled droplets, biomarkers, particle size distribution, surfactants, chronic obstructive pulmonary disease, asthma
- MeSH terms
- Animals, Humans, Particle Size, Pulmonary Surfactants, Respiration Disorders, Surface-Active Agents, Biomarkers, Exhalation, Airway Remodeling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Exhaled particles and small airways. https://app.cochat.ai/papers/10.1186/s12931-019-0970-9
- The paper
- Bake, B., Larsson, P., Ljungkvist, G., Ljungström, E., & Olin, A.-C. (2019). Exhaled particles and small airways. Respiratory Research. https://doi.org/10.1186/s12931-019-0970-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.