Aortic dissection simulation models for clinical support: fluid-structure interaction vs. rigid wall models
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The management and prognosis of aortic dissection (AD) is often challenging and the use of personalised computational models is being explored as a tool to improve clinical outcome. Including vessel wall motion in such simulations can provide more realistic and potentially accurate results, but requires significant additional computational resources, as well as expertise. With clinical translation as the final aim, trade-offs between complexity, speed and accuracy are inevitable. The present study explores whether modelling wall motion is worth the additional expense in the case of AD, by carrying out fluid-structure interaction (FSI) simulations based on a sample patient case. METHODS: Patient-specific anatomical details were extracted from computed tomography images to provide the fluid domain, from which the vessel wall was extrapolated. Two-way fluid-structure interaction simulations were performed, with coupled Windkessel boundary conditions and hyperelastic wall properties. The blood was modelled using the Carreau-Yasuda viscosity model and turbulence was accounted for via a shear stress transport model. A simulation without wall motion (rigid wall) was carried out for comparison purposes. RESULTS: The displacement of the vessel wall was comparable to reports from imaging studies in terms of intimal flap motion and contraction of the true lumen. Analysis of the haemodynamics around the proximal and distal false lumen in the FSI model showed complex flow structures caused by the expansion and contraction of the vessel wall. These flow patterns led to significantly different predictions of wall shear stress, particularly its oscillatory component, which were not captured by the rigid wall model. CONCLUSIONS: Through comparison with imaging data, the results of the present study indicate that the fluid-structure interaction methodology employed herein is appropriate for simulations of aortic dissection. Regions of high wall shear stress were not significantly altered by the wall motion, however, certain collocated regions of low and oscillatory wall shear stress which may be critical for disease progression were only identified in the FSI simulation. We conclude that, if patient-tailored simulations of aortic dissection are to be used as an interventional planning tool, then the additional complexity, expertise and computational expense required to model wall motion is indeed justified.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hemodynamic shear stress and its role in atherosclerosis
Malek, A. M. (1999) · JAMA · doi:10.1001/jama.282.21.2035 · Cited by 3,650 · cited 2×
“rupture [25], calcification [38] or wall thickening [36].”
BackgroundKu, D. N., Giddens, D. P., Zarins, C. K., & Glagov, S. (1985) · Arteriosclerosis: An Official Journal of the American Heart Association, Inc. · doi:10.1161/01.atv.5.3.293 · Cited by 2,707 · cited 6×
“Figure 8b shows the percentage change in the calculated OSI due to wall motion.”
BackgroundInfluentialChiu, J.-J., & Chien, S. (2011) · Physiological Reviews · doi:10.1152/physrev.00047.2009 · Cited by 2,280 · cited 1×
“permeability and ‘stickiness’ along with inflammatory responses [25,26,38,39].”
BackgroundErbel, R. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2782 · Cited by 1,217
Meng, H., Tutino, V. M., Xiang, J., & Siddiqui, A. (2014) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3558 · Cited by 955 · cited 3×
“and low wall shear stress, which has been identified as a potential index of high risk regions for aneurysm rupture [25,26].”
BackgroundHemodynamic–Morphologic Discriminants for Intracranial Aneurysm Rupture
Xiang, J., Natarajan, S. K., Tremmel, M., Ma, D., Mocco, J., Hopkins, L. N., Siddiqui, A. H., Levy, E. I., & Meng, H. (2011) · Stroke · doi:10.1161/strokeaha.110.592923 · Cited by 782 · cited 3×
“and low wall shear stress, which has been identified as a potential index of high risk regions for aneurysm rupture [25,26].”
BackgroundGijsen, F. J. H., van de Vosse, F. N., & Janssen, J. D. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00015-9 · Cited by 580 · cited 1×
“[18] has been widely cited, and was thus used in this study.”
MethodInterdisciplinary Expert Consensus Document on Management of Type B Aortic Dissection
Fattori, R., Cao, P., De Rango, P., Czerny, M., Evangelista, A., Nienaber, C., Rousseau, H., & Schepens, M. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.072 · Cited by 494 · cited 1×
“an FL is formed, the disease has high mortality rates [1], and if untreated only 40% of”
BackgroundTsai, T. T., Trimarchi, S., & Nienaber, C. A. (2009) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2008.11.032 · Cited by 447 · cited 2×
“downstream organ ischemia, severe hypertension, excessive enlargement of false lumen, leak and rupture [4,5].”
BackgroundGrabenwoger, M., Alfonso, F., Bachet, J., Bonser, R., Czerny, M., Eggebrecht, H., Evangelista, A., Fattori, R., Jakob, H., Lonn, L., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs074 · Cited by 410
On Coupling a Lumped Parameter Heart Model and a Three-Dimensional Finite Element Aorta Model
Kim, H. J., Vignon-Clementel, I. E., Figueroa, C. A., LaDisa, J. F., Jansen, K. E., Feinstein, J. A., & Taylor, C. A. (2009) · Annals of Biomedical Engineering · doi:10.1007/s10439-009-9760-8 · Cited by 333 · cited 1×
“There is a growing amount of literature on FSI simulations of aortae [16,17,27-29], using various models for the structure of the vessel wall [30,31] in order to capture the”
MethodThe IRAD Classification System for Characterizing Survival after Aortic Dissection
Booher, A. M., Isselbacher, E. M., Nienaber, C. A., Trimarchi, S., Evangelista, A., Montgomery, D. G., Froehlich, J. B., Ehrlich, M. P., Oh, J. K., Januzzi, J. L., et al. (2013) · The American Journal of Medicine · doi:10.1016/j.amjmed.2013.01.020 · Cited by 302
External tissue support and fluid–structure simulation in blood flows
Moireau, P., Xiao, N., Astorino, M., Figueroa, C. A., Chapelle, D., Taylor, C. A., & Gerbeau, J.-F. (2012) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-011-0289-z · Cited by 244 · cited 1×
“There is a growing amount of literature on FSI simulations of aortae [16,17,27-29], using various models for the structure of the vessel wall [30,31] in order to capture the”
MethodFluid–structure interaction simulation of aortic blood flow
Crosetto, P., Reymond, P., Simone Deparis, A., Kontaxakis, D., Stergiopulos, N., & Quarteroni, A. M. (2010) · Computers & Fluids · doi:10.1016/j.compfluid.2010.11.032 · Cited by 221 · cited 5×
“Although the solution will be partly dependent on the choice of material properties for the wall, a large range of Young’s moduli have been reported in the literature, from 0.4 to 6 MPa [28,41,42] and it is not clear what material properties are most appropriate for modelling the arterial wall, particularly in AD.”
BackgroundMethodInfluentialReymond, P., Crosetto, P., Deparis, S., Quarteroni, A. M., & Stergiopulos, N. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2012.08.009 · Cited by 201 · cited 2×
“There is a growing amount of literature on FSI simulations of aortae [16,17,27-29], using various models for the structure of the vessel wall [30,31] in order to capture the”
BackgroundMethodAnalysis of Flow Patterns in a Patient-Specific Aortic Dissection Model
Cheng, Z., Tan, F. P. P., Riga, C. V., Bicknell, C. D., Hamady, M., Gibbs, R. G. J., Wood, N. B., & Xu, X. Y. (2010) · Journal of Biomechanical Engineering · doi:10.1115/1.4000964 · Cited by 158 · cited 3×
“As an alternative, patient-tailored computational-fluid dynamics (CFD) approaches, wherein imaging data is used to construct a model of the patient’s aorta in which the flow is simulated, can provide data on WSS and pressure with high resolution [8-11].”
MethodPathogenesis of Acute Aortic Dissection: A Finite Element Stress Analysis
Nathan, D. P., Xu, C. D., Gorman, J. H., Fairman, R. M., Bavaria, J. E., Gorman, R. C., Chandran, K. B., & Jackson, B. M. (2011) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2010.10.042 · Cited by 129 · cited 1×
“Once such models have been developed and validated, it will be possible to accurately estimate the internal stresses in the wall of a dissected aorta, which may provide further clinical indicators [40].”
BackgroundThubrikar, P. A. M. J. (1999) · Journal of Medical Engineering & Technology · doi:10.1080/030919099294177 · Cited by 128 · cited 1×
“[37] also correlated elevated WSS with sites of intimal tears.”
BackgroundCheng, Z., Riga, C. V., Chan, J. M. S., Hamady, M., Wood, N. B., Cheshire, N. J. W., Xu, Y., & Gibbs, R. G. J. (2013) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2012.07.061 · Cited by 110 · cited 1×
“As an alternative, patient-tailored computational-fluid dynamics (CFD) approaches, wherein imaging data is used to construct a model of the patient’s aorta in which the flow is simulated, can provide data on WSS and pressure with high resolution [8-11].”
MethodChandra, S., Raut, S. S., Jana, A., Biederman, R. W., Doyle, M., Muluk, S. C., & Finol, E. A. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4024275 · Cited by 100 · cited 1×
“There is a growing amount of literature on FSI simulations of aortae [16,17,27-29], using various models for the structure of the vessel wall [30,31] in order to capture the”
MethodInvestigation of Pulsatile Flowfield in Healthy Thoracic Aorta Models
Wen, C., Yang, A., Tseng, L.-Y., & Chai, J. (2009) · Annals of Biomedical Engineering · doi:10.1007/s10439-009-9835-6 · Cited by 95 · cited 2×
“rupture [25], calcification [38] or wall thickening [36].”
BackgroundAnalysis of flow patterns in a patient-specific thoracic aortic aneurysm model
Tan, F. P. P., Borghi, A., Mohiaddin, R. H., Wood, N. B., Thom, S., & Xu, X. Y. (2008) · Computers & Structures · doi:10.1016/j.compstruc.2008.09.007 · Cited by 92 · cited 2×
“Although it has still not been established how best to model blood in the aorta, studies have shown that including turbulence allows slightly improved estimates of blood velocity when compared with pcMRI data [20,21].”
ResultA patient-specific study of type-B aortic dissection: evaluation of true-false lumen blood exchange
Chen, D., Müller–Eschner, M., von Tengg‐Kobligk, H., Barber, D. C., Böckler, D., Hose, R., & Ventikos, Y. (2013) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-12-65 · Cited by 79 · cited 1×
“The shear-stress transport turbulence model (a hybrid k-ε, k-ω method) was applied [9,19,20], with 1% turbulence intensity at the inlet, similar to previous studies [9,21].”
Ganten, M., Weber, T. F., von Tengg‐Kobligk, H., et al. (2008) · European Journal of Radiology · doi:10.1016/j.ejrad.2008.06.024 · Cited by 77 · cited 2×
“[33] and they observed a mean TL cross-sectional area reduction (-4.”
BackgroundAn automatic segmentation and classification framework for anti-nuclear antibody images
Cheng, C.-C., Hsieh, T., Taur, J. S., & Chen, Y.-F. (2013) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-12-s1-s5 · Cited by 72
Yang, S., Li, X., Chao, B., Wu, L., Cheng, Z., Duan, Y., Wu, D., Zhan, Y., Chen, J., Liu, B., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0087664 · Cited by 38 · cited 1×
“[35] is more characteristic of true flap motion than previous reports [33,34], then it is clear that the loss of accuracy through the rigid wall simplification would be exacerbated.”
Background
Metadata
- Authors
- Alimohammadi, M., Sherwood, J. M., Karimpour, M., Agu, O., Balabani, S., & Díaz-Zuccarini, V.
- Venue
- BioMedical Engineering OnLine
- Published
- 2015-04-15
- Volume
- 14
- Issue
- 1
- Pages
- 34-34
- ISSN
- 1475-925X (ISSN-L)
- OpenAlex
- W2061512169
- Cited by
- 158
- References
- 26
- FWCI
- 6.42
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.