Medical telerobotic systems: current status and future trends
Open accessThe DOI matches its Crossref record; 81 of the 81 references it cites were found in a registry or an index.
Abstract
Teleoperated medical robotic systems allow procedures such as surgeries, treatments, and diagnoses to be conducted across short or long distances while utilizing wired and/or wireless communication networks. This study presents a systematic review of the relevant literature between the years 2004 and 2015, focusing on medical teleoperated robotic systems which have witnessed tremendous growth over the examined period. A thorough insight of telerobotics systems discussing design concepts, enabling technologies (namely robotic manipulation, telecommunications, and vision systems), and potential applications in clinical practice is provided, while existing limitations and future trends are also highlighted. A representative paradigm of the short-distance case is the da Vinci Surgical System which is described in order to highlight relevant issues. The long-distance telerobotics concept is exemplified through a case study on diagnostic ultrasound scanning. Moreover, the present review provides a classification into short- and long-distance telerobotic systems, depending on the distance from which they are operated. Telerobotic systems are further categorized with respect to their application field. For the reviewed systems are also examined their engineering characteristics and the employed robotics technology. The current status of the field, its significance, the potential, as well as the challenges that lie ahead are thoroughly discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Corke, P., Roberts, J., Cunningham, J., & Hainsworth, D. (2008) · Springer Handbook of Robotics · doi:10.1007/978-3-540-30301-5_50 · Cited by 3,543
Design and Kinematic Modeling of Constant Curvature Continuum Robots: A Review
Webster, R. J., & Jones, B. A. (2010) · The International Journal of Robotics Research · doi:10.1177/0278364910368147 · Cited by 2,297 · cited 1×
“They consist of a concentric tubes assembly, with member tubes allowed to telescopically extend/rotate relevant to each other along/about their common axis [16].”
BackgroundAdvanced video coding for generic audiovisual services
Jtc, I.-T. A. I. I. (2010) · Medical Entomology and Zoology · Cited by 1,973
Bilateral teleoperation: An historical survey
Hokayem, P. F., & Spong, M. W. (2006) · Automatica · doi:10.1016/j.automatica.2006.06.027 · Cited by 1,671 · cited 4×
“Hokayem and Spong in [21] gave a historical survey on”
BackgroundMethodInfluentialHaptic feedback in robot-assisted minimally invasive surgery
Okamura, A. M. (2009) · Current Opinion in Urology · doi:10.1097/mou.0b013e32831a478c · Cited by 708
Telemanipulation with Time Delays
Niemeyer, G., & Slotine, J.-J. E. (2004) · The International Journal of Robotics Research · doi:10.1177/0278364904045563 · Cited by 539 · cited 2×
“Niemeyer and Slotine [22] applied the wave variable concept, an extension to the theory of passivity, to time-delayed teleoperation assuming an unknown but constant time delay.”
BackgroundMethodRobotic technology in surgery: Past, present, and future
Camarillo, D. B., Krummel, T. M., & Salisbury, J. K. (2004) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2004.08.025 · Cited by 535 · cited 1×
“Robotic systems were first introduced in medicine in the mid-80’s and today they make an impact in various medical disciplines including general surgery, neurosurgery, and orthopedic surgery [1–5].”
BackgroundA Review of Mobile Robotic Telepresence
Kristoffersson, A., Coradeschi, S., & Loutfi, A. (2013) · Advances in Human-Computer Interaction · doi:10.1155/2013/902316 · Cited by 375 · cited 1×
“manipulate objects, and interact with them thanks to haptic feedback [14].”
BackgroundRaven-II: An Open Platform for Surgical Robotics Research
Hannaford, B., Rosen, J., Friedman, D. W., King, H., Roan, P., Cheng, L., Glozman, D., Ma, J., Kosari, S. N., & White, L. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2228858 · Cited by 372
Force-reflection and shared compliant control in operating telemanipulators with time delay
Kim, W. S., Hannaford, B., & Fejczy, A. K. (1992) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.134272 · Cited by 361 · cited 1×
“Results presented in [22, 31] considered that the communication time delay between master–slave teleoperators is constant.”
Background
Cited by
Internet of Things for Current COVID-19 and Future Pandemics: an Exploratory Study
Nasajpour, M., Pouriyeh, S., Parizi, R. M., Dorodchi, M., Valero, M., & Arabnia, H. R. (2020) · Journal of Healthcare Informatics Research · doi:10.1007/s41666-020-00080-6 · Cited by 304
Reddy, K., Gharde, P., Tayade, H., Patil, M., Reddy, L. S., & Surya, D. (2023) · Cureus · doi:10.7759/cureus.50415 · Cited by 263
Designing Futuristic Telemedicine Using Artificial Intelligence and Robotics in the COVID-19 Era
Bhaskar, S., Bradley, S., Sakhamuri, S., Moguilner, S., Chattu, V. K., Pandya, S., Schroeder, S., Ray, D., & Banach, M. (2020) · Frontiers in Public Health · doi:10.3389/fpubh.2020.556789 · Cited by 137
Panayides, A. S., Pattichis, M. S., Pantziaris, M., Constantinides, A. G., & Pattichis, C. S. (2020) · IEEE Access · doi:10.1109/access.2020.2965325 · Cited by 27
Self-citation
Metadata
- Authors
- Avgousti, S., Christoforou, E. G., Panayides, A. S., Voskarides, S., Novales, C., Nouaille, L., Pattichis, C. S., & Vieyres, P.
- Venue
- BioMedical Engineering OnLine
- Published
- 2016-08-12
- Volume
- 15
- Issue
- 1
- Pages
- 96-96
- ISSN
- 1475-925X (ISSN-L)
- OpenAlex
- W2509798008
- Cited by
- 170
- References
- 81
- FWCI
- 7.97
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.