ECG signal feature extraction trends in methods and applications
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Signal analysis is a domain which is an amalgamation of different processes coming together to form robust pipelines for the automation of data analysis. When applied to the medical world, physiological signals are used. It is becoming increasingly common in today’s day and age to be working with very large datasets, on the scale of having thousands of features. This is largely due to the fact that the acquisition of biomedical signals can be taken over multi-hour timeframes, which is another challenge to solve in and of itself. This paper will focus on the electrocardiogram (ECG) signal specifically, and common feature extraction techniques used for digital health and artificial intelligence (AI) applications. Feature extraction is a vital step of biomedical signal analysis. The basic goal of feature extraction is for signal dimensionality reduction and data compaction. In simple terms, this would allow one to represent data with a smaller subset of features; these features could then later be leveraged to be used more efficiently for machine learning and deep learning models for applications, such as classification, detection, and automated applications. In addition, the redundant data in the overall dataset is filtered out as the data is reduced during feature extraction. In this review, we cover ECG signal processing and feature extraction in the time domain, frequency domain, time–frequency domain, decomposition, and sparse domain. We also provide pseudocode for the methods discussed so that they can be replicated by practitioners and researchers in their specific areas of biomedical work. Furthermore, we discuss deep features, and machine learning integration, to complete the overall pipeline design for signal analysis. Finally, we discuss future work that can be innovated upon in the feature extraction domain for ECG signal analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855 · cited 3×
“This is a highly reliable and accurate algorithm that is able to recognize QRS complexes [11, 12].”
MethodMarkel, J. D., & Gray, A. H. (1976) · Communication and Cybernetics · doi:10.1007/978-3-642-66286-7 · Cited by 1,402 · cited 1×
“Apply Levinson–Durbin’s Algorithm from [14]”
The use of the Hilbert transform in ECG signal analysis
Benitez, D., Gaydecki, P. A., Zaidi, A., & Fitzpatrick, A. P. (2001) · Computers in Biology and Medicine · doi:10.1016/s0010-4825(01)00009-9 · Cited by 489 · cited 6×
“Hilbert transform Accurate Performs excellently even in the presence of significant noise in the signal Future work required to overcome the challenges faced when using other leads with this method QRS detection [16]”
BackgroundMethodInfluentialAn approach to cardiac arrhythmia analysis using hidden Markov models
Coast, D. A., Stern, R. M., Cano, G. G., & Briller, S. A. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.58593 · Cited by 475 · cited 6×
“The goal is for the beats to be accurately identified by their wavefront components; this would allow for complete arrhythmia analysis; each waveform is assumed to correspond with the Markov process [15].”
BackgroundMethodInfluentialFast QRS Detection with an Optimized Knowledge-Based Method: Evaluation on 11 Standard ECG Databases
Elgendi, M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0073557 · Cited by 264 · cited 2×
“This is a highly reliable and accurate algorithm that is able to recognize QRS complexes [11, 12].”
BackgroundMethodDetecting ventricular fibrillation
Afonso, V. X., & Tompkins, W. J. (1995) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.376752 · Cited by 149 · cited 19×
“(7)W12(t, f ) = ∫ z1(t + Ŵ 2 )z2 ∗ (t + Ŵ 2 )e−j2�f ŴdŴ The tensors used in this study were constructed using the short-time Fourier transform (STFT) on the raw ECG signals.”
BackgroundMethodInfluentialQRS feature extraction using linear prediction
Lin, K.-P., & Chang, W. H.-S. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.40806 · Cited by 130 · cited 10×
“Popular methods in the time domain, like LPC, have been shown to have fast processing, but again face the issue of the LPC coefficients not carrying enough information about the ECG signals for a robust analysis.”
BackgroundMethodInfluentialECG-Based Subject Identification Using Statistical Features and Random Forest
Alotaiby, T. N., Alrshoud, S. R., Alshebeili, S. A., & Aljafar, L. M. (2019) · Journal of Sensors · doi:10.1155/2019/6751932 · Cited by 40 · cited 6×
“Statistical features Simple implementation Computationally inexpensive Not application-specific; statistical features can be extracted for many types of data, and may not always be the best choice for physiological signals like the ECG Biometric identification system with the use of ECG signals [7]”
BackgroundMethodInfluentialAn effective frequency-domain feature of atrial fibrillation based on time–frequency analysis
Hu, Y., Zhao, Y., Liu, J., Pang, J., Zhang, C., & Li, P. (2020) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-020-01337-1 · Cited by 36 · cited 4×
“Wavelet transform Excellent localization in the time and frequency domains simultaneously The presence of some arrhythmias may lead to inaccurate detection of QRS complexes [8] Applying 3-lead systems of ECG signal may cause the loss of signal information which could limit efficiency of the WT [8] Arrhythmia detection…”
BackgroundInfluentialA Comparative Approach to ECG Feature Extraction Methods
Molaei-Vaneghi, F., Oladazimi, M., Shiman, F., Kordi, A., Safari, M. J., & Ibrahim, F. (2012) · International Conference on Intelligent Systems, Modelling and Simulation · doi:10.1109/isms.2012.35 · Cited by 28 · cited 4×
“The data was sampled such that all the two-lead ECG signals in the analysis had a frequency of 250 Hz [9].”
MethodInfluential
Metadata
- Authors
- Singh, A. K., & Krishnan, S.
- Venue
- BioMedical Engineering OnLine
- Published
- 2023-03-08
- Volume
- 22
- Issue
- 1
- Pages
- 22-22
- ISSN
- 1475-925X (ISSN-L)
- OpenAlex
- W4323652738
- Cited by
- 170
- References
- 14
- FWCI
- 29.73
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ECG signal feature extraction trends in methods and applications. https://app.cochat.ai/papers/10.1186/s12938-023-01075-1
- The paper
- Singh, A. K., & Krishnan, S. (2023). ECG signal feature extraction trends in methods and applications. BioMedical Engineering OnLine. https://doi.org/10.1186/s12938-023-01075-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.