Clinical application and detection techniques of liquid biopsy in gastric cancer
Open accessThe DOI matches its Crossref record; 208 of the 208 references it cites were found in a registry or an index.
Abstract
Gastric cancer (GC) is one of the most common tumors worldwide and the leading cause of tumor-related mortality. Endoscopy and serological tumor marker testing are currently the main methods of GC screening, and treatment relies on surgical resection or chemotherapy. However, traditional examination and treatment methods are more harmful to patients and less sensitive and accurate. A minimally invasive method to respond to GC early screening, prognosis monitoring, treatment efficacy, and drug resistance situations is urgently needed. As a result, liquid biopsy techniques have received much attention in the clinical application of GC. The non-invasive liquid biopsy technique requires fewer samples, is reproducible, and can guide individualized patient treatment by monitoring patients' molecular-level changes in real-time. In this review, we introduced the clinical applications of circulating tumor cells, circulating free DNA, circulating tumor DNA, non-coding RNAs, exosomes, and proteins, which are the primary markers in liquid biopsy technology in GC. We also discuss the current limitations and future trends of liquid biopsy technology as applied to early clinical biopsy technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Items 201–208 of 208
circ_AKT3 knockdown suppresses cisplatin resistance in gastric cancer
Shi, W., & Wang, F. (2022) · Open Medicine · doi:10.1515/med-2021-0355 · Cited by 14 · cited 1×
“resistance and GC progression via sponge miR-1297 and miR-206, respectively, indicating that targeting SNHG6 and circ_AKT3 may be a promising option to address GC chemoresistance [166, 168].”
BackgroundIsothermal circular strand displacement–based assay for microRNA detection in liquid biopsy
Bellassai, N., D’Agata, R., & Spoto, G. (2022) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-022-04228-8 · Cited by 11 · cited 1×
“[181] developed a hairpin-probe-based isothermal strand replacement polymerization method for detecting miRNAs and used it to quantify osteoarthritis-associated miR-127 in joint fluid.”
MethodFeng, Q., Yang, Z., Zhang, J.-T., & Tang, J.-L. (2017) · Oncotarget · doi:10.18632/oncotarget.19110 · Cited by 10 · cited 1×
“PCR-based techniques include standard quantitative PCR (qPCR), digital PCR (dPCR) and droplet digital PCR (ddPCR), allele-specific PCR, quantitative methylationspecific PCR, BEAMing (beads, emulsions, amplification, and magnetism) [111–113], ARMS [114], and co-amplification at lower denaturation temperature-PCR [115].”
MethodClinical role of miR-421 as a novel biomarker in diagnosis of gastric cancer patients
Xu, Y., Wang, G., Hu, W., He, S., Li, D., Chen, P., Zhang, J., Gao, Y., Yu, D., & Zong, L. (2022) · Medicine · doi:10.1097/md.0000000000029242 · Cited by 10 · cited 1×
“[142] found that miR-21, miR-106, miR-421, and miR-223 have better diagnostic efficacy for GC, with miR-421 particularly useful as an auxiliary diagnostic indicator for GC; the AUC of its diagnostic GC can reach 0.”
BackgroundSelf-citationZhou, F., Ding, W., Mao, Q., Jiang, X., Chen, J., Zhao, X., Xu, W., Huang, J., Zhong, L., & Sun, X. (2022) · PeerJ · doi:10.7717/peerj.12629 · Cited by 9 · cited 1×
“In 5-fluorouracil (5-FU)resistant GC cells, hsacirc_004413 could make GC cells resistant to 5-FU by adsorbing miR-145-5p [167].”
BackgroundRNAdetect: efficient computational detection of novel non-coding RNAs
Chen, C., Qian, X., & Yoon, B.-J. (2018) · Bioinformatics · doi:10.1093/bioinformatics/bty765 · Cited by 8 · cited 1×
“[176] recently proposed RNAdetect, a computational method that incorporates novel predictive features based on generalized ensemble defects.”
MethodKonno, N., Suzuki, R., Takagi, T. J., Sugimoto, M., Asama, H., Sato, Y., Irie, H., Hikichi, T., & Ohira, H. (2020) · Journal of Hepato-Biliary-Pancreatic Sciences · doi:10.1002/jhbp.850 · Cited by 7
A single‐view field filter device for rare tumor cell filtration and enumeration
Quan, Y., Chen, K., Xiang, N., & Ni, Z. (2020) · Electrophoresis · doi:10.1002/elps.202000176 · Cited by 5
Cited by
Tumor biomarkers for diagnosis, prognosis and targeted therapy
Zhou, Y., Tao, L., Qiu, J., Xu, J., Yang, X., Zhang, Y., Tian, X., Guan, X., Cen, X., & Zhao, Y. (2024) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-024-01823-2 · Cited by 720
Pre-metastatic niche: formation, characteristics and therapeutic implication
Wang, Y., Jia, J., Wang, F., Fang, Y., Yang, Y., Zhou, Q., Yuan, W., Gu, X., Hu, J., & Yang, S. (2024) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-024-01937-7 · Cited by 246
Self-citation
Metadata
- Authors
- Ma, S., Zhou, M., Xu, Y., Gu, X., Zou, M., Abudushalamu, G., Yao, Y., Fan, X., & Wu, G.
- Venue
- Molecular Cancer
- Published
- 2023-01-11
- Volume
- 22
- Issue
- 1
- Pages
- 7-7
- ISSN
- 1476-4598 (ISSN-L)
- OpenAlex
- W4315487575
- Cited by
- 190
- References
- 208
- FWCI
- 18.44
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.