Evaluation of aortic stenosis using cardiovascular magnetic resonance: a systematic review & meta-analysis
Open accessThe DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Abstract
As the average age of patients with severe aortic stenosis (AS) who receive procedural intervention continue to age, the need for non-invasive modalities that provide accurate diagnosis and operative planning is increasingly important. Advances in cardiovascular magnetic resonance (CMR) over the past two decades mean it is able to provide haemodynamic data at the aortic valve, along with high fidelity anatomical imaging. Electronic databases were searched for studies comparing CMR to transthoracic echocardiography (TTE) and transoesophageal echocardiography (TEE) in the diagnosis of AS. Studies were included only if direct comparison was made on matched patients, and if diagnosis was primarily through measurement of aortic valve area (AVA). Twenty-three relevant, prospective articles were included in the meta-analysis, totalling 1040 individual patients. There was no significant difference in AVA measured as by CMR compared to TEE. CMR measurements of AVA size were larger compared to TTE by an average of 10.7% (absolute difference: + 0.14cm2, 95% CI 0.07–0.21, p < 0.001). Reliability was high for both inter- and intra-observer measurements (0.03cm2 +/− 0.04 and 0.02cm2 +/− 0.01, respectively). Our analysis demonstrates the equivalence of AVA measurements using CMR compared to those obtained using TEE. CMR demonstrated a small but significantly larger AVA than TTE. However, this can be attributed to known errors in derivation of left ventricular outflow tract size as measured by TTE. By offering additional anatomical assessment, CMR is warranted as a primary tool in the assessment and workup of patients with severe AS who are candidates for surgical or transcatheter intervention.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Although MRI generally demonstrates good overlap with echocardiography, MRI may produce greater aortic valve area estimates than echocardiography.39”
From Rare Genetic Variants in LDLR , APOB , and PCSK9 Are Associated With Aortic Stenosis (2024) · cites this paper as [39]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bonow, R. O., Carabello, B. A., Chatterjee, K., de Leon, A. C., Faxon, D. P., Freed, M. D., Gaasch, W. H., Lytle, B. W., Nishimura, R. A., O’Gara, P. T., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.176857 · Cited by 8,495
The Role of Stress Echocardiography in Valvular Heart Disease: A Current Appraisal
Gentry III, J. L., Phelan, D., Desai, M. Y., & Griffin, B. P. (2017) · Cardiology · doi:10.1159/000460274 · Cited by 2,725
Gorlin, R., & Gorlin, S. G. (1951) · American Heart Journal · doi:10.1016/0002-8703(51)90002-6 · Cited by 1,778
2014 AHA/ACC guideline for the management of patients with valvular heart disease
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2014.05.014 · Cited by 989
Achenbach, S., Delgado, V., Hausleiter, J., Schoenhagen, P., Min, J. K., & Leipsic, J. A. (2012) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2012.11.002 · Cited by 634
Azevedo, C. F., Nigri, M., Higuchi, M. L., Pomerantzeff, P. M., Spina, G. S., Sampaio, R. O., Tarasoutchi, F., Grinberg, M., & Rochitte, C. E. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.12.074 · Cited by 548 · cited 5×
“CMR has emerged as an alternate, non-invasive method, and offers prognostic and planning potential for procedural intervention in the form of transcatheter aortic valve implantation (TAVI) or surgical aortic valve replacement (SAVR).”
BackgroundInfluentialDetermination of the stenotic aortic valve area in adults using Doppler echocardiography
Otto, C. M., Pearlman, A. S., Comess, K. A., Reamer, R. P., Janko, C. L., & Huntsman, L. L. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80460-0 · Cited by 391
Caruthers, S. D., Lin, S. J., Brown, P., Watkins, M. P., Williams, T. A., Lehr, K. A., & Wickline, S. A. (2003) · Circulation · doi:10.1161/01.cir.0000095268.47282.a1 · Cited by 294
Aortic Valve Area Calculation in Aortic Stenosis by CT and Doppler Echocardiography
Clavel, M.-A., Malouf, J., Messika-Zeitoun, D., Araoz, P. A., Michelena, H. I., & Enriquez-Sarano, M. (2015) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2015.01.009 · Cited by 209
Jabbour, A., Ismail, T. F., Moat, N., Gulati, A., Roussin, I., Alpendurada, F., Park, B., Okoroafor, F., Asgar, A., Barker, S., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.09.010 · Cited by 202
Magnetic resonance to assess the aortic valve area in aortic stenosis
John, A. S., Dill, T., Brandt, R. R., Rau, M., Ricken, W., Bachmann, G., & Hamm, C. W. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00707-1 · Cited by 192
Heart valve disease: investigation by cardiovascular magnetic resonance
Myerson, S. G. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-7 · Cited by 171
Kupfahl, C., Honold, M., Meinhardt, G., Vogelsberg, H., Wagner, A., Mahrholdt, H., & Sechtem, U. (2004) · Heart · doi:10.1136/hrt.2003.022376 · Cited by 167
Introduction to Aortic Stenosis
Carabello, B. A. (2013) · Circulation Research · doi:10.1161/circresaha.113.300156 · Cited by 158
Pouleur, A., de Waroux, J. L. P., Pasquet, A., Vanoverschelde, J., & Gerber, B. L. (2007) · Radiology · doi:10.1148/radiol.2443061127 · Cited by 152
Planimetry of orifice area in aortic stenosis using multiplane transesophageal ecocardiography
Hoffman, R., Flachskampf, F. A., & HANRATH, P. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90060-e · Cited by 151
MRI phase contrast velocity and flow errors in turbulent stenotic jets
O’Brien, K., Cowan, B. R., Jain, M., Stewart, R., Kerr, A., & Young, A. A. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21395 · Cited by 145
Bahlmann, E., Cramariuc, D., Gerdts, E., Gohlke-Baerwolf, C., Nienaber, C. A., Eriksen, E., Wachtell, K., Chambers, J. B., Kück, K., & Ray, S. G. (2010) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2009.11.019 · Cited by 130
Kim, H. K., Gottliebson, W., Hor, K., Backeljauw, P., Gutmark-Little, I., Salisbury, S. R., Racadio, J. M., Helton-Skally, K., & Fleck, R. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.10.4973 · Cited by 126
Eichenberger, A. C., Jenni, R., & von Schulthess, G. K. (1993) · American Journal of Roentgenology · doi:10.2214/ajr.160.5.8470612 · Cited by 118
Quantification of valvular aortic stenosis by magnetic resonance imaging
Friedrich, M. G., Schulz‐Menger, J., Poetsch, T., Pilz, B., Uhlich, F., & Dietz, R. (2002) · American Heart Journal · doi:10.1067/mhj.2002.124057 · Cited by 109
Chin, C., Khaw, H., Luo, E., Tan, S., White, A. C., Newby, D. E., & Dweck, M. R. (2014) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2014.04.021 · Cited by 86
Cardiovascular magnetic resonance in systemic hypertension
Maceira, A. M., & Mohiaddin, R. H. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-28 · Cited by 81
Planimetry of Aortic Valve Area in Aortic Stenosis by Magnetic Resonance Imaging
Debl, K., Djavidani, B., Seitz, J., Nitz, W. R., Schmid, F., Muders, F., Büchner, S., Feuerbach, S., Riegger, G. N. A. J., & Luchner, A. (2005) · Investigative Radiology · doi:10.1097/01.rli.0000178362.67085.fd · Cited by 77
Réant, P., Léderlin, M., Lafitte, S., Serri, K., Montaudon, M., Corneloup, O., Roudaut, R. P., & Laurent, F. (2006) · European Journal of Radiology · doi:10.1016/j.ejrad.2006.02.011 · Cited by 74
Barone‐Rochette, G., Piérard, S., Seldrum, S., de Meester, C., Melchior, J., Maes, F., Pouleur, A., Vancraeynest, D., Pasquet, A., Vanoverschelde, J., et al. (2013) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.113.000515 · Cited by 71
O’Brien, K., Gabriel, R. S., Greiser, A., Cowan, B. R., Young, A. A., & Kerr, A. (2009) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-11-49 · Cited by 61
Defrance, C., Bollache, É., Kachenoura, N., Perdrix, L., Hrynchyshyn, N., Bruguière, É., Redheuil, A. B., Diébold, B., & Mousseaux, É. (2012) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.111.971218 · Cited by 59
Paelinck, B. P., Herck, P. L. V., Rodrigus, I. E. R., Claeys, M. J., Laborde, J., Parizel, P. M., Vrints, C. J., & Bosmans, J. M. (2011) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2011.02.348 · Cited by 55
Advanced cardiac MRI techniques for evaluation of left‐sided valvular heart disease
Blanken, C. P. S., Farag, E. S., Boekholdt, S. M., Leiner, T., Kluin, J., Nederveen, A. J., van Ooij, P., & Planken, R. N. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26204 · Cited by 54
Mohiaddin, R. H., Gatehouse, P. D., Henien, M., & Firmin, D. N. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070408 · Cited by 51
4D flow magnetic resonance imaging: role in pediatric congenital heart disease
Lawley, C. M., Broadhouse, K. M., Callaghan, F. M., Winlaw, D. S., Figtree, G. A., & Grieve, S. M. (2017) · Asian Cardiovascular and Thoracic Annals · doi:10.1177/0218492317694248 · Cited by 49
Self-citationFeasibility of Cardiovascular Magnetic Resonance to Assess the Orifice Area of Aortic Bioprostheses
von Knobelsdorff‐Brenkenhoff, F., Rudolph, A., Waßmuth, R., Bohl, S., Buschmann, E. E., Abdel‐Aty, H., Dietz, R., & Schulz‐Menger, J. (2009) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.108.840967 · Cited by 48
Pontone, G., Andreini, D., Bartorelli, A. L., Bertella, E., Mushtaq, S., Gripari, P., Loguercio, M., Cortinovis, S., Baggiano, A., Conte, E., et al. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2013.07.050 · Cited by 43
García, J., Capoulade, R., Ven, F. L., Gaillard, E., Kadem, L., Pîbarot, P., & Larose, É. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-84 · Cited by 41
MRI in Chronic Aortic Dissection: A Systematic Review and Future Directions
Sherrah, A. G., Grieve, S. M., Jeremy, R., Bannon, P. G., Vallely, M. P., & Puranik, R. (2015) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2015.00005 · Cited by 38
Self-citationJoziasse, I. C., Vink, A., Cramer, M. J., van Oosterhout, M. F. M., van Herwerden, L. A., Heijmen, R. H., Sieswerda, G. T., Mulder, B. J. M., & Doevendans, P. A. (2011) · Netherlands Heart Journal · doi:10.1007/s12471-010-0060-6 · Cited by 37
Simplified Bernoulli's method significantly underestimates pulmonary transvalvular pressure drop
Falahatpisheh, A., Rickers, C., Gabbert, D. D., Heng, E. L., Stalder, A. F., Kramer, H., Kilner, P. J., & Kheradvar, A. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25097 · Cited by 36
Lee, S. C., Ko, S. M., Song, M. G., Shin, J. K., Chee, H. K., & Hwang, H. K. (2012) · International journal of cardiac imaging · doi:10.1007/s10554-012-0066-9 · Cited by 31
Malyar, N. M., Schlosser, T. W., Barkhausen, J., Gutersohn, A., Buck, T., Bartel, T., & Erbel, R. M. (2007) · Cardiology · doi:10.1159/000105554 · Cited by 30
Sommer, G., Bremerich, J., & Lund, G. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23544 · Cited by 28
Sherrah, A. G., Callaghan, F. M., Puranik, R., Jeremy, R., Bannon, P. G., Vallely, M. P., & Grieve, S. M. (2017) · Aorta · doi:10.12945/j.aorta.2017.16.046 · Cited by 24
Self-citationWestermann, Y., Geigenmüller, A., Elgeti, T., Wagner, M., Dushe, S., Borges, A. C., Dohmen, P. M., Hein, P. A., & Lembcke, A. E. (2009) · European Journal of Radiology · doi:10.1016/j.ejrad.2009.08.014 · Cited by 22
Whitener, G. B., Sivak, J. A., Akushevich, I. V., Samad, Z. Z., & Swaminathan, M. (2016) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2016.05.012 · Cited by 19
Sherrah, A. G., Callaghan, F. M., Puranik, R., et al. (2017) · Aorta · doi:10.12945/j.aorta.2016.16.046 · Cited by 19
Cardiac MR Imaging in the Evaluation of Rheumatic Valvular Heart Diseases
Mutnuru, P. C., Singh, S. N., D'Souza, J. P., & Perubhotla, L. M. (2016) · JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH · doi:10.7860/jcdr/2016/18059.7405 · Cited by 15
Functional Assessment of Bioprosthetic Aortic Valves by CMR
Maragiannis, D., Jackson, M., Flores‐Arredondo, J. H., Autry, K., Schutt, R. C., Alvarez, P. A., Zoghbi, W. A., Shah, D. J., & Little, S. H. (2016) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2015.08.025 · Cited by 15
Lévy, F., Iacuzio, L., Civaia, F., Rusek, S., Dommerc, C., Hugues, N., Alexandrescu, C., Dor, V., Tribouilloy, C. M., & Dreyfus, G. (2016) · Archives of cardiovascular diseases · doi:10.1016/j.acvd.2016.04.006 · Cited by 15
Hemodynamic Assessment of Severe Aortic Stenosis
Weininger, M., Sagmeister, F., Herrmann, S., Lange, V., Schoepf, U. J., Beissert, M., Voelker, W., Köstler, H., Hahn, D., Weidemann, F., et al. (2010) · Investigative Radiology · doi:10.1097/rli.0b013e3181f79ca2 · Cited by 14
Büchner, S., Debl, K., Schmid, F., Luchner, A., & Djavidani, B. (2015) · BMC Medical Imaging · doi:10.1186/s12880-015-0076-x · Cited by 13
Cardiac Magnetic Resonance Imaging for the Interventional Cardiologist
Figtree, G. A., Lønborg, J., Grieve, S. M., Ward, M. R., & Bhindi, R. (2011) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2010.09.026 · Cited by 11
Self-citationBruder, O., Jochims, M., Hunold, P., Jensen, C. J., Forsting, M., Sabin, G. V., Barkhausen, J., & Schlosser, T. W. (2009) · Acta Radiologica · doi:10.1080/02841850902902540 · Cited by 9
3-T magnetic resonance for determination of aortic valve area: A comparison to echocardiography
Speiser, U., Quick, S., Haas, D., Youssef, A. A., Waessnig, N. K., Ibrahim, K. S., Strasser, R. H., & Schoen, S. (2014) · Scandinavian Cardiovascular Journal · doi:10.3109/14017431.2014.906646 · Cited by 6
Sherif, M., İnce, H., Maniuc, O., Reiter, T., Voelker, W., Ertl, G., & Öner, A. Ö. (2015) · BMC Cardiovascular Disorders · doi:10.1186/s12872-015-0181-3 · Cited by 6
Planimetry of Orifice Area in Aortic Stenosis Using Multiplane Transesophageal Echocardiography
(1994) · Journal of diagnostic medical sonography · doi:10.1177/875647939401000124 · Cited by 5
Dimitriou, P., Kähäri, A., Emilsson, K., & Thunberg, P. (2012) · Acta Radiologica · doi:10.1258/ar.2012.120261 · Cited by 3
MRI in chronic aortic dissection: A systematic review and future directions
Sherrah, A. G., Grieve, S. M., Jeremy, R., Bannon, P. G., Vallely, M. P., & Puranik, R. (2015) · Heart Lung and Circulation · doi:10.1016/j.hlc.2014.12.094 · Cited by 3
Self-citationKanchi, M. (2016) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2016.11.032 · Cited by 3
Planimetry of orifice area in aortic stenosis using multiplane transesophageal echocardiography
Hoffmann, R., Flachskampf, F. A., & Hanrath, P. (1993) · RWTH Publications (RWTH Aachen) · Cited by 2
Research works printed but not linked: 3
- ACR Manual on Contrast Media. 10 ed. Virginia, USA: ACR Committee on Drugs and Contrast Media; 2017 Jun pp. 1-129.
- Eichenberger AC, Jenni R, Von Schulthess GK. Aortic Valve Pressure Gradients in Patients with Aortic Valve Stenosis. Am J Radiol. 1993;160:971-7.
- Weininger M, Sagmeister F, Herrmann S, Lange V, Schoepf UJ, Beissert M, et al. Hemodynamic assessment of severe aortic stenosis: MRI evaluation of dynamic changes of vena contracta. Investig Radiol. 2011;46(1):1-10. · DOI
Cited by
Magalhães, T. A., Carneiro, A. C. D. C., Moreira, V. D. M., Trad, H. S., Uellendahl, M. M., Cerci, R., Nacif, M. S., Schvartzman, P. R., Chagas, A. C. P., Costa, I. B. S. D. S., et al. (2024) · Arquivos Brasileiros de Cardiologia · doi:10.36660/abc.20240608 · Cited by 30
Ageing, Hypertension and Aortic Valve Stenosis: A Conscious Uncoupling
Hungerford, S. L., Adji, A. I., Hayward, C., & Muller, D. W. (2021) · Heart Lung and Circulation · doi:10.1016/j.hlc.2021.05.108 · Cited by 27
Rare Genetic Variants in LDLR , APOB , and PCSK9 Are Associated With Aortic Stenosis
Rämö, J. T., Jurgens, S. J., Kany, S., Choi, S. H., Wang, X., Smirnov, A. N., Friedman, S. F., Maddah, M., Khurshid, S., Ellinor, P. T., et al. (2024) · Circulation · doi:10.1161/circulationaha.124.070982 · Cited by 26
“39 Therefore, our MRI results are in need of further replication using standard echocardiography measurements.”
A novel method to assess valvulo-arterial load in patients with aortic valve stenosis
Hungerford, S. L., Adji, A. I., Bart, N., Lin, L., Namasivayam, M. J., Schnegg, B., Jabbour, A., O’Rourke, M. F., Hayward, C., & Muller, D. W. (2020) · Journal of Hypertension · doi:10.1097/hjh.0000000000002648 · Cited by 19
Guzzetti, E., Annabi, M., Pîbarot, P., & Clavel, M.-A. A. (2020) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2020.570689 · Cited by 15
Metadata
- Authors
- Woldendorp, K., Bannon, P. G., & Grieve, S. M.
- Affiliations
- The University of Sydney (AU)
- Corresponding author
- Grieve, Stuart M.
- Venue
- Journal of Cardiovascular Magnetic Resonance
- Publisher
- Elsevier BV
- Published
- 2020-01
- Volume
- 22
- Issue
- 1
- Pages
- 45
- ISSN
- 1097-6647 (ISSN-L)
- PMC
- PMC7294634
- OpenAlex
- W3034595767
- Cited by
- 32
- References
- 59
- Citations by year
- 2026: 4 · 2025: 1 · 2024: 6 · 2023: 3 · 2022: 9 · 2021: 6 · 2020: 2
- FWCI
- 0.85
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- creativecommons.org/licenses/by/4.0/ (vor, 166 d)
- Locations
- Journal of Cardiovascular Magnetic Resonance (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Valve Diseases and Treatments
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Aortic Disease and Treatment Approaches
- Keywords
- aortic stenosis, cardiovascular magnetic resonance, aortic valve area, transthoracic echocardiography, transesophageal echocardiography, non-invasive diagnosis, left ventricular outflow tract, measurement agreement, transcatheter aortic valve, aortic valve surgery
- MeSH terms
- Clinical Decision-Making, Aged, Aged, 80 and over, Aortic Valve, Aortic Valve Insufficiency, Aortic Valve Stenosis, Female, Hemodynamics, Humans, Magnetic Resonance Imaging, Male, Middle Aged, Predictive Value of Tests, Prognosis, Severity of Illness Index, Reproducibility of Results, Observer Variation, Echocardiography, Transesophageal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.