A systematic review of the applications of markerless motion capture (MMC) technology for clinical measurement in rehabilitation
Open accessThe DOI matches its Crossref record; 81 of the 81 references it cites were found in a registry or an index.
Abstract
Background: Markerless motion capture (MMC) technology has been developed to avoid the need for body marker placement during motion tracking and analysis of human movement. Although researchers have long proposed the use of MMC technology in clinical measurement—identification and measurement of movement kinematics in a clinical population, its actual application is still in its preliminary stages. The benefits of MMC technology are also inconclusive with regard to its use in assessing patients’ conditions. In this review we put a minor focus on the method’s engineering components and sought primarily to determine the current application of MMC as a clinical measurement tool in rehabilitation. Methods: A systematic computerized literature search was conducted in PubMed, Medline, CINAHL, CENTRAL, EMBASE, and IEEE. The search keywords used in each database were “Markerless Motion Capture OR Motion Capture OR Motion Capture Technology OR Markerless Motion Capture Technology OR Computer Vision OR Video-based OR Pose Estimation AND Assessment OR Clinical Assessment OR Clinical Measurement OR Assess.” Only peer-reviewed articles that applied MMC technology for clinical measurement were included. The last search took place on March 6, 2023. Details regarding the application of MMC technology for different types of patients and body parts, as well as the assessment results, were summarized. Results: A total of 65 studies were included. The MMC systems used for measurement were most frequently used to identify symptoms or to detect differences in movement patterns between disease populations and their healthy counterparts. Patients with Parkinson’s disease (PD) who demonstrated obvious and well-defined physical signs were the largest patient group to which MMC assessment had been applied. Microsoft Kinect was the most frequently used MMC system, although there was a recent trend of motion analysis using video captured with a smartphone camera. Conclusions: This review explored the current uses of MMC technology for clinical measurement. MMC technology has the potential to be used as an assessment tool as well as to assist in the detection and identification of symptoms, which might further contribute to the use of an artificial intelligence method for early screening for diseases. Further studies are warranted to develop and integrate MMC system in a platform that can be user-friendly and accurately analyzed by clinicians to extend the use of MMC technology in the disease populations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Poewe, W., Seppi, K., Tanner, C. M., Halliday, G. M., Brundin, P., Volkmann, J., Schrag, A.-E., & Lang, A. E. (2017) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2017.13 · Cited by 5,415
A report: the definition and classification of cerebral palsy April 2006
(2007) · Developmental Medicine & Child Neurology · doi:10.1111/j.1469-8749.2007.tb12610.x · Cited by 4,793
Accuracy of the Microsoft Kinect sensor for measuring movement in people with Parkinson's disease
Galna, B., Barry, G., Jackson, D., Mhiripiri, D., Olivier, P., & Rochester, L. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2014.01.008 · Cited by 544
A Review on Technical and Clinical Impact of Microsoft Kinect on Physical Therapy and Rehabilitation
Mousavi Hondori, H., & Khademi, M. (2014) · Journal of Medical Engineering · doi:10.1155/2014/846514 · Cited by 360 · cited 2×
“Mousavi Hondori and Khademi [12] reviewed the clinical impact of Kinect in rehabilitation, but their study did not cover other types of MMC technology.”
BackgroundThe Definition and Classification of Cerebral Palsy
Rosenbaum, P. (2006) · NeoReviews · doi:10.1542/neo.7-11-e569 · Cited by 242
Markerless Motion Capture through Visual Hull, Articulated ICP and Subject Specific Model Generation
Corazza, S., Mündermann, L., Gambaretto, E., Ferrigno, G., & Andriacchi, T. P. (2010) · International Journal of Computer Vision · doi:10.1007/s11263-009-0284-3 · Cited by 220
HOPE-Net: A Graph-Based Model for Hand-Object Pose Estimation
Doosti, B., Naha, S., Mirbagheri, M., & Crandall, D. J. (2020) · 2020 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr42600.2020.00664 · Cited by 215
de Belen, R. A. J., Bednarz, T. P., Sowmya, A., & Favero, D. D. (2020) · Translational Psychiatry · doi:10.1038/s41398-020-01015-w · Cited by 185
A vision-based analysis system for gait recognition in patients with Parkinson’s disease
Cho, C., Chao, W.-H., Lin, S.-H., & Chen, Y. (2008) · Expert Systems with Applications · doi:10.1016/j.eswa.2008.08.076 · Cited by 163
Knippenberg, E., Verbrugghe, J., Lamers, I., Palmaers, S., Timmermans, A. A. A., & Spooren, A. I. F. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0270-x · Cited by 163 · cited 1×
“Review studies have been conducted on the use of MMC technology in rehabilitation training, but not in regard to its use in clinical measurement including application of MMC technology in clinical assessment and detection of kinematic parameters that assist in disease diagnosis [11].”
Metadata
- Authors
- Lam, W. W. T., Tang, Y. M., & Fong, K. N. K.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2023-05-02
- Volume
- 20
- Issue
- 1
- Pages
- 57-57
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W4367675509
- Cited by
- 207
- References
- 81
- FWCI
- 9.01
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A systematic review of the applications of markerless motion capture (MMC) technology for clinical measurement in rehabilitation. https://app.cochat.ai/papers/10.1186/s12984-023-01186-9
- The paper
- Lam, W. W. T., Tang, Y. M., & Fong, K. N. K. (2023). A systematic review of the applications of markerless motion capture (MMC) technology for clinical measurement in rehabilitation. Journal of NeuroEngineering and Rehabilitation. https://doi.org/10.1186/s12984-023-01186-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.