HyperArc VMAT planning for single and multiple brain metastases stereotactic radiosurgery: a new treatment planning approach
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
The HyperArc VMAT (HA-VMAT) planning approach was newly developed to fulfill the demands of dose delivery for brain metastases stereotactic radiosurgery. We compared the dosimetric parameters of the HA-VMAT plan with those of the conventional VMAT (C-VMAT). For 23 patients (1–4 brain metastases), C-VMAT and HA-VMAT plans with a prescription dose of 20–24 Gy were retrospectively generated, and dosimetric parameters for PTV (homogeneity index, HI; conformity index, CI; gradient index, GI) and brain tissue (V 2Gy -V 16Gy ) were evaluated. Subsequently, the physical characteristics (modulation complexity score for VMAT, MCSV; Monitor unit, MU) of both treatment approaches were compared. HA-VMAT provided higher HI (1.41 ± 0.07 vs. 1.24 ± 0.07, p < 0.01), CI (0.93 ± 0.02 vs. 0.90 ± 0.05, p = 0.01) and lower GI (3.06 ± 0.42 vs. 3.91 ± 0.55, p < 0.01) values. Moderate-to-low dose spreads (V 4Gy -V 16Gy ) were significantly reduced ( p < 0.01) in the HA-VMAT plan over that of C-VMAT. HA-VMAT plans resulted in more complex MLC patterns (lower MCSV, p < 0.01) and higher MU ( p < 0.01). HA-VMAT plans provided significantly higher conformity and rapid dose falloff with respect to the C-VMAT plans.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kocher, M., Soffietti, R., Abacioglu, U., Villà, S., Fauchon, F., Baumert, B. G., Fariselli, L., Tzuk-Shina, T., Kortmann, R.-D., Carrie, C., et al. (2011) · Journal of Clinical Oncology · doi:10.1200/jco.2010.30.1655 · Cited by 1,988
Radiation therapy oncology group: Radiosurgery quality assurance guidelines
Shaw, E., Kline, R., Gillin, M., Souhami, L., Hirschfeld, A., Dinapoli, R., & Martin, L. (1993) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(93)90548-a · Cited by 748 · cited 1×
“The homogeneity index (HI) was defined as follows: HI = Dmax/Dprescribed, where Dmax and Dprescribed denote the maximum and prescribed doses, respectively [10].”
MethodTsao, M. N., Rades, D., Wirth, A., Lo, S. S., Danielson, B. L., Gaspar, L. E., Sperduto, P. W., Vogelbaum, M. A., Radawski, J. D., Wang, J. Z., et al. (2012) · Practical Radiation Oncology · doi:10.1016/j.prro.2011.12.004 · Cited by 587 · cited 1×
“The American Society for Radiation Oncology published guidelines for management for brain metastasis, in which SRS is considered as the primary selection to improve survival and may be the best treatment choice for multiple brain metastases when quality of life is considered as the most important outcome [4].”
BackgroundBlonigen, B. J., Steinmetz, R. D., Levin, L., Lamba, M. A., Warnick, R. E., & Breneman, J. C. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.06.006 · Cited by 506 · cited 10×
“Recently, a new solution to fulfill the demands of SRS dose delivery has been developed by Varian Medical Systems.”
MethodInfluentialManagement of brain metastases
Soffietti, R., Rudā, R., & Mutani, R. (2002) · Journal of Neurology · doi:10.1007/s00415-002-0870-6 · Cited by 404
Radiosurgery for brain metastases: Relationship of dose and pattern of enhancement to local control
Shiau, C.-Y., Sneed, P. K., Shu, H.-K. G., Lamborn, K. R., McDermott, M. W., Chang, S., Nowak, P., Petti, P. L., Smith, V., Verhey, L. J., et al. (1997) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(96)00497-x · Cited by 265 · cited 1×
“showed that longer interval of freedom before progression of the tumor after SRS for brain metastases was significantly associated with a higher prescription dose and a minimum dose ≥18 Gy was found to yield excellent local control [16].”
BackgroundKatz, A., & Kang, J. (2014) · Radiation Oncology · doi:10.1186/1748-717x-9-1 · Cited by 214
Liu, H., Andrews, D. W., Evans, J. J., Werner‐Wasik, M., Yu, Y., Dicker, A. P., & Shi, W. (2016) · Frontiers in Oncology · doi:10.3389/fonc.2016.00026 · Cited by 81 · cited 1×
“Moreover, there is a new generation of treatment units such as Cyber Knife and Gamma Knife [25, 26].”
BackgroundGevaert, T., Steenbeke, F., Pellegri, L., Engels, B., Christian, N., Hoornaert, M.-T., Verellen, D., Mitine, C., & Ridder, M. D. (2016) · Radiation Oncology · doi:10.1186/s13014-016-0593-y · Cited by 66 · cited 1×
“have demonstrated the superiority of Element over conventional dynamic conformal arc therapy [24].”
BackgroundFeasibility of extreme dose escalation for glioblastoma multiforme using 4π radiotherapy
Nguyen, D. T. D., Rwigema, J. M., Yu, V., Kaprealian, T. B., Kupelian, P. A., Selch, M. T., Lee, P. P., Low, D. A., & Sheng, K. (2014) · Radiation Oncology · doi:10.1186/s13014-014-0239-x · Cited by 53 · cited 1×
“The 4π optimization method begins with a candidate pool of 1162 beams evenly distributed throughout the 4π solid angle space with 6° of separation between adjacent beams [20].”
Method
Cited by
Complexity metrics for IMRT and VMAT plans: a review of current literature and applications
Chiavassa, S., Bessieres, I., Edouard, M., Mathot, M., & Moignier, A. (2019) · The British Journal of Radiology · doi:10.1259/bjr.20190270 · Cited by 159
Kuil, L. E., Varkevisser, T. M. C. K., Huisman, M. H., Jansen, M., Bunt, J., Compter, A., Ket, H., Schagen, S. B., Meeteren, A. Y. N. S.-V., & Partanen, M. (2024) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2023.105514 · Cited by 4
“The cognitive impairments tend to be subtle, as patients typically score within the low average range on cognitive tests in both adult 16,17 and pediatric cases 18 .”
Metadata
- Authors
- Ohira, S., Ueda, Y., Akino, Y., Hashimoto, M., Masaoka, A., Hirata, T., Miyazaki, M., Koizumi, M., & Teshima, T.
- Venue
- Radiation Oncology
- Published
- 2018-01-29
- Volume
- 13
- Issue
- 1
- Pages
- 13-13
- ISSN
- 1748-717X (ISSN-L)
- OpenAlex
- W2793899998
- Cited by
- 167
- References
- 11
- FWCI
- 12.92
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: HyperArc VMAT planning for single and multiple brain metastases stereotactic radiosurgery: a new treatment planning approach. https://app.cochat.ai/papers/10.1186/s13014-017-0948-z
- The paper
- Ohira, S., Ueda, Y., Akino, Y., Hashimoto, M., Masaoka, A., Hirata, T., Miyazaki, M., Koizumi, M., & Teshima, T. (2018). HyperArc VMAT planning for single and multiple brain metastases stereotactic radiosurgery: a new treatment planning approach. Radiation Oncology. https://doi.org/10.1186/s13014-017-0948-z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.