Is mean heart dose a relevant surrogate parameter of left ventricle and coronary arteries exposure during breast cancer radiotherapy: a dosimetric evaluation based on individually-determined radiation dose (BACCARAT study)
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Intra-individual heterogeneity of cardiac exposure is an issue in breast cancer (BC) radiotherapy that was poorly considered in previous cardiotoxicity studies mainly based on mean heart dose (MHD). This dosimetric study analyzes the distribution of individually-determined radiation doses to the heart and its substructures including coronary arteries and evaluate whether MHD is a relevant surrogate parameter of dose for these substructures. Data were collected from the BACCARAT prospective study that included left or right unilateral BC patients treated with 3D-Conformal Radiotherapy (RT) between 2015 and 2017 and followed-up for 2 years with repeated cardiac imaging examinations. A coronary computed tomography angiography (CCTA) was performed before RT for all patients. Registration of the planning CT and CCTA images allowed delineation of the coronary arteries on the planning CT images. Using the 3D dose matrix generated during treatment planning and the added coronary contours, dose distributions were generated for whole heart and the following substructures: left ventricle (LV), left main coronary artery (LMCA), left anterior descending artery (LAD), left circumflex artery (LCX) and right coronary artery (RCA). A descriptive analysis of the physical doses in Gray (Gy) was performed, Dmean was the volume-weighted mean dose. Dose distributions were generated for 89 left-sided BC patients (MHD = 2.9 ± 1.5 Gy, Dmean_LAD = 15.7 ± 3.1 Gy) and 15 right-sided BC patients (MHD = 0.5 ± 0.1 Gy; Dmean_RCA = 1.2 ± 0.4 Gy). For left-sided BC patients, the ratio Dmean_LAD/MHD was around 5. Pearson correlation coefficients between MHD and Dmean for delineated substructures were all statistically significant. However, for all substructures, the coefficient of determination R2 indicated that the proportion of the variance in Dmean of the substructure predictable from MHD was moderate to low (in particular R2 = 0.45 for LAD). Among left-sided BC patients with MHD < 3Gy, 56% of patients could nevertheless receive LAD doses above 40Gy (V40 > 0). Our study illustrates that MHD is not enough to predict with confidence individual patient dose to the LV and coronary arteries, in particular the LAD. For precise radiotherapy-induced cardiotoxicity studies it would be necessary to consider the distribution of doses within these cardiac substructures rather than just the MHD. ClinicalTrials.gov: NCT02605512 , Registered 6 November 2015 - Retrospectively registered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nagueh, S. F., Smiseth, O. A., Appleton, C. P., Byrd, B. F., Dokainish, H., Edvardsen, T., Flachskampf, F. A., Gillebert, T. C., Klein, A. L., Lancellotti, P., et al. (2016) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2016.01.011 · Cited by 5,262 · cited 1×
“Assessment of left ventricular function is extremely important as it correlates with symptoms, prognosis, events, and complications in a large number of conditions and many decisions in cardiology are based on left ventricular function [23] .”
BackgroundRisk of Ischemic Heart Disease in Women after Radiotherapy for Breast Cancer
Darby, S. C., Ewertz, M., McGale, P., Bennet, A. M., Blom-Goldman, U., Brønnum, D., Correa, C., Cutter, D., Gagliardi, G., Gigante, B., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1209825 · Cited by 3,974 · cited 4×
“In Darby’s study [5], estimated mean doses to the LAD and MHD were also Table 3 Association parameters between mean dose to the left ventricle and coronary arteries and the mean heart dose”
BackgroundInfluentialNagueh, S. F., Smiseth, O. A., Appleton, C. P., Byrd, B. F., Dokainish, H., Edvardsen, T., Flachskampf, F. A., Gillebert, T. C., Klein, A. L., Lancellotti, P., et al. (2016) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jew082 · Cited by 2,425
Radiation Dose–Volume Effects in the Heart
Gagliardi, G., Constine, L. S., Moiseenko, V., Correa, C., Pierce, L. J., Allen, A. M., & Marks, L. B. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.04.093 · Cited by 1,227
Darby, S. C., McGale, P., Taylor, C. W., & Peto, R. (2005) · The Lancet Oncology · doi:10.1016/s1470-2045(05)70251-5 · Cited by 1,049
Feng, M., Moran, J. M., Koelling, T., Chughtai, A., Chan, J. L., Freedman, L., Hayman, J. A., Jagsi, R., Jolly, S., Larouere, J., et al. (2011) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.10.058 · Cited by 715 · cited 2×
“Dreaming of a ‘Swiss Army Knife’ for cardiac doses, some studies developed methodology based on atlas and auto-segmentation that could help to standardize contouring for these structures [12, 13, 25, 26].”
BackgroundMethodRisk of Cardiac Death After Adjuvant Radiotherapy for Breast Cancer
Giordano, S. H., Kuo, Y.-F., Freeman, J. L., Buchholz, T. A., Hortobagyi, G. N., & Goodwin, J. S. (2005) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/dji067 · Cited by 552
van den Bogaard, V. A. B., Ta, B. D. P., van der Schaaf, A., Bouma, A. B., Middag, A. M. H., Bantema-Joppe, E. J., van Dijk, L. V., van Dijk-Peters, F. B. J., Marteijn, L. A. W., de Bock, G. H., et al. (2017) · Journal of Clinical Oncology · doi:10.1200/jco.2016.69.8480 · Cited by 511 · cited 3×
“However, there is increasing evidence toward the importance to consider individual cardiac substructures as some studies have implicated the left anterior descending artery [10, 19], as well as the left ventricle [7] as important components of the heart associated with radiation induced heart disease.”
BackgroundResultCorrea, C. R., Litt, H. I., Hwang, W.-T., Ferrari, V. A., Solin, L. J., & Harris, E. E. (2007) · Journal of Clinical Oncology · doi:10.1200/jco.2006.08.6595 · Cited by 392 · cited 2×
“However, there is increasing evidence toward the importance to consider individual cardiac substructures as some studies have implicated the left anterior descending artery [10, 19], as well as the left ventricle [7] as important components of the heart associated with radiation induced heart disease.”
BackgroundResultDistribution of Coronary Artery Stenosis After Radiation for Breast Cancer
Nilsson, G., Holmberg, L., Garmo, H., Duvernoy, O., Sjögren, I., Lagerqvist, B., & Blomqvist, C. (2012) · Journal of Clinical Oncology · doi:10.1200/jco.2011.34.5900 · Cited by 386 · cited 3×
“However, there is increasing evidence toward the importance to consider individual cardiac substructures as some studies have implicated the left anterior descending artery [10, 19], as well as the left ventricle [7] as important components of the heart associated with radiation induced heart disease.”
BackgroundTaylor, C. W., Wang, Z., Macaulay, E., Jagsi, R., Duane, F., & Darby, S. C. (2015) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2015.07.2292 · Cited by 332
Cardiac Exposures in Breast Cancer Radiotherapy: 1950s–1990s
Taylor, C. W., Nisbet, A., McGale, P., & Darby, S. C. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2007.05.034 · Cited by 314 · cited 2×
“Although there was considerable decrease in doses to the heart over past few years [8, 17, 18], radiation induced heart disease is still a concern due to the improvement in breast cancer patients survival.”
BackgroundA cardiac contouring atlas for radiotherapy
Duane, F., Aznar, M. C., Bartlett, F., Cutter, D. J., Darby, S. C., Jagsi, R., Lorenzen, E. L., McArdle, O., McGale, P., Myerson, S., et al. (2017) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2017.01.008 · Cited by 308 · cited 1×
“Dreaming of a ‘Swiss Army Knife’ for cardiac doses, some studies developed methodology based on atlas and auto-segmentation that could help to standardize contouring for these structures [12, 13, 25, 26].”
BackgroundCardiac Dose From Tangential Breast Cancer Radiotherapy in the Year 2006
Taylor, C. W., Povall, J. M., McGale, P., Nisbet, A., Dodwell, D., Smith, J. T., & Darby, S. C. (2008) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2007.12.058 · Cited by 236 · cited 1×
“Although there was considerable decrease in doses to the heart over past few years [8, 17, 18], radiation induced heart disease is still a concern due to the improvement in breast cancer patients survival.”
BackgroundA Systematic Review of Heart Dose in Breast Radiotherapy
Drost, L., Yee, C., Lam, H., Zhang, L., Wronski, M., McCann, C., Lee, J., Vesprini, D., Leung, E., & Chow, E. (2018) · Clinical Breast Cancer · doi:10.1016/j.clbc.2018.05.010 · Cited by 125
Jacob, S., Pathak, A., Franck, D., Latorzeff, I., Jimenez, G., Fondard, O., Lapeyre, M., Colombier, D., Bruguière, É., Lairez, O., et al. (2016) · Radiation Oncology · doi:10.1186/s13014-016-0627-5 · Cited by 99 · cited 1×
“Material and methods The BACCARAT study, a monocentric prospective cohort study further detailed in a previous article [15], Jacob et al.”
MethodSelf-citationKaderka, R., Gillespie, E. F., Mundt, R. C., Bryant, A. K., Sanudo-Thomas, C. B., Harrison, A. L., Wouters, E. L., Moiseenko, V., Moore, K. L., Atwood, T. F., et al. (2018) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2018.07.013 · Cited by 84 · cited 1×
“Dreaming of a ‘Swiss Army Knife’ for cardiac doses, some studies developed methodology based on atlas and auto-segmentation that could help to standardize contouring for these structures [12, 13, 25, 26].”
BackgroundMoignier, A., Broggio, D., Derreumaux, S., Beaudré, A., Girinsky, T., Paul, J., Drubay, D., Lefkopoulos, D., Franck, D., Aubert, B., et al. (2015) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2015.07.043 · Cited by 64 · cited 3×
“For dosimetric evaluation, the simulation CT scan, the CCTA, the RT dose and RT structure files in DICOM format were used as done in a previous study [14] .”
BackgroundMethodSelf-citationOffersen, B. V., Højris, I., & Overgaard, M. (2011) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2011.08.007 · Cited by 48 · cited 1×
“No dose recommendation exists for the coronary arteries, except one Danish study proposed a threshold with a maximum of 20Gy to be given to the LAD [28] .”
BackgroundDuma, M. N., Herr, A.-C., Borm, K. J., Trott, K. R., Molls, M., Oechsner, M., & Combs, S. E. (2017) · Frontiers in Oncology · doi:10.3389/fonc.2017.00130 · Cited by 36 · cited 1×
“As a consequence, MHD may be a poor surrogate parameter to reflect the dose to the cardiac sub-structures especially the LAD [11] and MHD may thus be a poorly relevant dose criterion for RT-induced cardiotoxicity studies and dose-response relationship.”
BackgroundBecker-Schiebe, M., Stockhammer, M., Hoffmann, W., Wetzel, F., & Franz, H. B. G. (2016) · Strahlentherapie und Onkologie · doi:10.1007/s00066-016-1011-y · Cited by 29 · cited 1×
“With MHD as low as possible, the coronary arteries exposure could be as low as possible ad gating is an option to decrease the doses [22, 29] but we could not test it in our study as only 4 patients were concerned.”
BackgroundMoignier, A., Broggio, D., Derreumaux, S., Baf, F. E., Mandin, A., Girinsky, T., Paul, J., Chea, M., Jenny, C., Franck, D., et al. (2014) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.01.055 · Cited by 27 · cited 2×
“But, dose distribution in the heart is not homogeneous, highest cardiac radiation doses can be observed in the apex and in the apical-anterior segment and some hot spots>50Gy persist in some parts of the heart [9].”
BackgroundSelf-citationEdvardsson, A., Nilsson, M., Amptoulach, S., & Ceberg, S. (2015) · Radiation Oncology · doi:10.1186/s13014-015-0375-y · Cited by 23 · cited 1×
“With MHD as low as possible, the coronary arteries exposure could be as low as possible ad gating is an option to decrease the doses [22, 29] but we could not test it in our study as only 4 patients were concerned.”
BackgroundDosimetric evaluation of right coronary artery in radiotherapy for breast cancer
Altinok, A., Askeroğlu, M. O., Doyuran, M., Çağlar, M., Cantürk, E., Erol, C., & Beşe, N. (2018) · Medical dosimetry · doi:10.1016/j.meddos.2018.06.006 · Cited by 10 · cited 1×
“results were concordant with those previously published [24] with a mean dose to the RCA of 1.”
Result
Cited by
Lyon, A. R., López-Fernández, T., Couch, L. S., Asteggiano, R., Aznar, M. C., Bergler-Klein, J., Boriani, G., Cardinale, D., Cordoba, R., Cosyns, B., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac244 · Cited by 3,076
Lyon, A. R., López-Fernández, T., Couch, L. S., Asteggiano, R., Aznar, M. C., Bergler-Klein, J., Boriani, G., Cardinale, D., Cordoba, R., Cosyns, B., et al. (2022) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeac106 · Cited by 507
Atkins, K. M., Chaunzwa, T. L., Lamba, N., Bitterman, D. S., Rawal, B., Bredfeldt, J., Williams, C. L., Kozono, D. E., Baldini, E. H., Nohria, A., et al. (2021) · JAMA Oncology · doi:10.1001/jamaoncol.2020.6332 · Cited by 241
Metadata
- Authors
- Jacob, S., Camilleri, J., Derreumaux, S., Walker, V., Lairez, O., Lapeyre, M., Bruguière, E., Pathak, A., Bernier, M.-O., Laurier, D., Ferrieres, J., Gallocher, O., Latorzeff, I., Pinel, B., Franck, D., Chevelle, C., Jimenez, G., & Broggio, D.
- Venue
- Radiation Oncology
- Published
- 2019-02-07
- Volume
- 14
- Issue
- 1
- Pages
- 29-29
- ISSN
- 1748-717X (ISSN-L)
- OpenAlex
- W2919716094
- Cited by
- 175
- References
- 26
- FWCI
- 16.47
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.