CoChat

Diagnostic accuracy of delirium diagnosis in pediatric intensive care: a systematic review

Open access
Daoud, Alia, Duff, Jonathan P, Joffe, Ari R, for the Alberta Sepsis Network · 2014 · Critical Care
Cited by 68

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Introduction: Delirium is common in adult intensive care, with validated tools for measurement, known risk factors and adverse neurocognitive outcomes. We aimed to determine what is known about pediatric delirium in the pediatric intensive care unit (PICU). Methods: We conducted a systematic search for and review of studies of the accuracy of delirium diagnosis in children in the PICU. Secondary aims were to determine the prevalence, risk factors and outcomes associated with pediatric delirium. We created screening and data collection tools based on published recommendations. Results: After screening 145 titles and abstracts, followed by 35 full-text publications and reference lists of included publications, 9 reports of 5 studies were included. Each of the five included studies was on a single index test: (1) the Pediatric Anesthesia Emergence Delirium Scale (PAED; for ages 1 to 17 years), (2) the Pediatric Confusion Assessment Method for the Intensive Care Unit (p-CAM-ICU; for ages ≥5 years), (3) the Cornell Assessment of Pediatric Delirium (CAP-D; a modification of the PAED designed to detect hypoactive delirium), (4) the revised Cornell Assessment of Pediatric Delirium (CAP-D(R)) and (5) clinical suspicion. We found that all five studies had a high risk of bias on at least one domain in the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2). Sample size, sensitivity, specificity, and effectiveness (correct classification divided by total tests done) were: PAED 144, 91%, 98%, <91% (>16% of scores required imputation for missing data); p-CAM 68, 78%, 98%, 96%; CAP-D 50, 91%, 100%, 89%; CAP-D (R) 111, and of assessments 94%, 79%, <82% (it is not clear if any assessments were not included); and clinical suspicion 877, N/A (only positive predictive value calculable, 66%). Prevalence of delirium was 17%, 13%, 28%, 21%, and 5% respectively. Only the clinical suspicion study researchers statistically determined any risk factors for delirium (pediatric risk of mortality, pediatric index of mortality, ventilation, age) or outcomes of delirium (length of stay and mortality). Conclusion: High-quality research to determine the accuracy of delirium screening tools in the PICU are required before prevalence, risk factors and outcomes can be determined and before a routine screening tool can be recommended. Direct comparisons of the p-CAM-ICU and CAP-D(R) should be performed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s13054-014-0489-x

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 68

Metadata

Authors
Daoud, A., Duff, J. P., Joffe, A. R., & for the Alberta Sepsis Network
Venue
Critical Care
Published
2014-09-26
Volume
18
Issue
5
Pages
489-489
ISSN
1364-8535 (ISSN-L)
OpenAlex
W2130774346
Cited by
68
References
4
FWCI
0.96
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic accuracy of delirium diagnosis in pediatric intensive care: a systematic review. https://app.cochat.ai/papers/10.1186/s13054-014-0489-x
The paper
Daoud, A., Duff, J. P., Joffe, A. R., & for the Alberta Sepsis Network. (2014). Diagnostic accuracy of delirium diagnosis in pediatric intensive care: a systematic review. Critical Care. https://doi.org/10.1186/s13054-014-0489-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.