CoChat

Control of Line Complications with KiteLock (CLiCK) in the critical care unit: study protocol for a multi-center, cluster-randomized, double-blinded, crossover trial investigating the effect of a novel locking fluid on central line complications in the critical care population

Ornowska, Marlena, Wong, Hubert, Ouyang, Yongdong, Mitra, Anish, White, Aaron, Willems, Sue, Wittmann, Jessica, Reynolds, Steven · 2022 · Trials
Cited by 10

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background: Insertion of a central venous access device (CVAD) allows clinicians to easily access the circulation of a patient to administer life-saving interventions. Due to their invasive nature, CVADs are prone to complications such as bacterial biofilm production and colonization, catheter-related bloodstream infection, occlusion, and catheter-related venous thrombosis. A CVAD is among the most common interventions for patients in the intensive care unit (ICU), exposing this vulnerable population to the risk of nosocomial infection and catheter occlusion. The current standard of care involves the use of normal saline as a catheter locking solution for central venous catheters (CVCs) and peripherally inserted central catheter (PICC) lines, and a citrate lock for hemodialysis catheters. Saline offers little prophylactic measures against catheter complications. Four percent of tetrasodium ethylenediaminetetraacetic acid (EDTA) fluid (marketed as KiteLock Sterile Locking Solution™) is non-antibiotic, possesses antimicrobial, anti-biofilm, and anti-coagulant properties, and is approved by Health Canada as a catheter locking solution. As such, it may be a superior CVAD locking solution than the present standard of care lock in the ICU patient population. Methods: Our team proposes to fill this knowledge gap by performing a multi-center, cluster-randomized, crossover trial evaluating the impact of 4% tetrasodium EDTA on a primary composite outcome of the incidence rate of central line-associated bloodstream infection (CLABSI), catheter occlusion leading to removal, and use of alteplase to resolve catheter occlusion compared to the standard of care. The study will be performed at five critical care units. Discussion: If successful, the results of this study can serve as evidence for a shift of standard of care practices to include EDTA locking fluid in routine CVAD locking procedures. Completion of this study has the potential to improve CVAD standard of care to become safer for patients, as well as provides an opportunity to decrease strain on healthcare budgets related to treating preventable CVAD complications. Success and subsequent implementation of this intervention in the ICU may also be extrapolated to other patient populations with heavy CVAD use including hemodialysis, oncology, parenteral nutrition, and pediatric patient populations. On a global scale, eradicating biofilm produced by antibiotic-resistant bacteria may serve to lessen the threat of “superbugs” and contribute to international initiatives supporting the termination of antibiotic overuse. Trial registration: ClinicalTrials.gov NCT04548713, registered on September 9th, 2020.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s13063-022-06671-5

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 33

  1. Frasca D, Dahyot-Fizelier C, Mimoz O. Prevention of central venous catheter-related infection in the intensive care unit. Crit Care. 2010;14(2):212. · DOI · Paper page
  2. Takashima M, Schults J, Mihala G, Corley A, Ullman A. Complication and failures of central vascular access device in adult critical care settings*. Crit Care Med. 2018;46(12):1998–2009. · DOI
  3. Dudeck MA, Edwards JR, Allen-Bridson K, Gross C, Malpiedi PJ, Peterson KD, et al. National Healthcare Safety Network report, data summary for 2013, device-associated module. Am J Infect Control. 2015;43(3):206–21. · DOI · Paper page
  4. Holton D, Paton S, Conly J, Embree J, Taylor G, Thompson W, et al. Central venous catheter-associated blood stream infections occurring in Canadian intensive care units: a six-month cohort study. Can J Infect Dis Med Microbiol. 2006;17(3):169–76. · doi:10.1155/2006/781735
  5. Ryder M. Catheter-related infections: it’s all about biofilm. Top Adv Pract Nurs eJ. 2005;5(3):1–6.
  6. Laupland KB, Lee H, Gregson DB, Manns BJ. Cost of intensive care unit-acquired bloodstream infections. J Hosp Infect. 2006;63(2):124–32. · DOI
  7. Ryder M. The role of biofilm in vascular catheter-related infections. N Dev Vasc Dis. 2001;2:15–25.
  8. Burns KEA, McLaren A. A critical review of thromboembolic complications associated with central venous catheters. Can J Anesth. 2008;55(8):532–41. · DOI
  9. Bagnall-Reeb H. Diagnosis of central venous access device occlusion. Implications for nursing practice. J Intraven Nurs. 1998;21(Suppl 5):S115–21.
  10. Baskin JL, Reiss U, Wilimas JA, Metzger ML, Ribeiro RC, Pui C-H, et al. Thrombolytic therapy for central venous catheter occlusion. Haematologica. 2012;97(5):641–50. · doi:10.3324/haematol.2011.050492
  11. Ernst FR, Chen E, Lipkin C, Tayama D, Amin AN. Comparison of hospital length of stay, costs, and readmissions of alteplase versus catheter replacement among patients with occluded central venous catheters: outcomes in CVC Occlusions. J Hosp Med. 2014;9(8):490–6. · doi:10.1002/jhm.2208
  12. Kleindorfer D, Broderick J, Demaerschalk B, Saver J. Cost of alteplase has more than doubled over the past decade. Stroke. 2017;48(7):2000–2. · doi:10.1161/strokeaha.116.015822
  13. Ahmed I, Majeed A, Powell R. Heparin induced thrombocytopenia: diagnosis and management update. Postgrad Med J. 2007;83(983):575–82. · doi:10.1136/pgmj.2007.059188
  14. Shanks RMQ, Sargent JL, Martinez RM, Graber ML, O’Toole GA. Catheter lock solutions influence staphylococcal biofilm formation on abiotic surfaces. Nephrol Dial Transplant. 2006;21(8):2247–55. · DOI · Paper page
  15. Dal Molin A, Allara E, Montani D, Milani S, Frassati C, Cossu S, et al. Flushing the central venous catheter: is heparin necessary? J Vasc Access. 2014;15(4):241–8. · DOI
  16. López-Briz E, Ruiz Garcia V, Cabello JB, Bort-Marti S, Carbonell Sanchis R, Burls A. Heparin versus 0.9% sodium chloride intermittent flushing for prevention of occlusion in central venous catheters in adults. Cochrane Database Syst Rev. 2014;(10):CD008462. · DOI
  17. Zacharioudakis IM, Zervou FN, Arvanitis M, Ziakas PD, Mermel LA, Mylonakis E. Antimicrobial lock solutions as a method to prevent central line–associated bloodstream infections: a meta-analysis of randomized controlled trials. Clin Infect Dis. 2014;59(12):1741–9. · DOI
  18. Wolf J, Connell TG, Allison KJ, Tang L, Richardson J, Branum K, et al. Treatment and secondary prophylaxis with ethanol lock therapy for central line-associated bloodstream infection in paediatric cancer: a randomised, double-blind, controlled trial. Lancet Infect Dis. 2018;18(8):854–63. · DOI
  19. Pérez-Granda MJ, Barrio JM, Muñoz P, Hortal J, Rincón C, Rabadán PM, et al. Ethanol lock therapy (E-Lock) in the prevention of catheter-related bloodstream infections (CR-BSI) after major heart surgery (MHS): a randomized clinical trial. PLoS One. 2014;9(3):e91838. · DOI
  20. Schallom ME, Prentice D, Sona C, Micek ST, Skrupky LP. Heparin or 0.9% sodium chloride to maintain central venous catheter patency: a randomized trial. Crit Care Med. 2012;40(6):1820–6. · DOI
  21. Quenot J-P, Helms J, Bourredjem A, Dargent A, Meziani F, Badie J, et al. Trisodium citrate 4% versus heparin as a catheter lock for non-tunneled hemodialysis catheters in critically ill patients: a multicenter, randomized clinical trial. Ann Intensive Care. 2019;9(1):75. · doi:10.1186/s13613-019-0553-4
  22. Banfi G, Salvagno GL, Lippi G. The role of ethylenediamine tetraacetic acid (EDTA) as in vitro anticoagulant for diagnostic purposes. Clin Chem Lab Med. 2007;45(5):565–76. · DOI · Paper page
  23. Liu F, Hansra S, Crockford G, Köster W, Allan BJ, Blondeau JM, et al. Tetrasodium EDTA is effective at eradicating biofilms formed by clinically relevant microorganisms from patients’ central venous catheters. mSphere. 2018;3(6):e00525–18. · DOI · Paper page
  24. Kanaa M, Wright MJ, Akbani H, Laboi P, Bhandari S, Sandoe JAT. Cathasept line lock and microbial colonization of tunneled hemodialysis catheters: a multicenter randomized controlled trial. Am J Kidney Dis. 2015;66(6):1015–23. · DOI
  25. Quirt J, Belza C, Pai N, Clause R-F, Markovic F, Wong-Sterling S, et al. Reduction of central line-associated bloodstream infections and line occlusions in pediatric intestinal failure patients receiving long-term parenteral nutrition using an alternative locking solution, 4% tetrasodium ethylenediaminetetraacetic acid. JPEN J Parenter Enteral Nutr. 2021;45(6):1286–92. · DOI
  26. Hill J, Garner R. Efficacy of 4% tetrasodium ethylenediaminetetraacetic acid (T-EDTA) catheter lock solution in home parenteral nutrition patients: a quality improvement evaluation. J Vasc Access. 2021;22(4):533–9. · doi:10.1177/1129729820946916
  27. Mermel LA, Allon M, Bouza E, Craven DE, Flynn P, O’Grady NP, et al. Clinical practice guidelines for the diagnosis and management of intravascular catheter-related infection: 2009 update by the Infectious Diseases Society of America. Clin Infect Dis. 2009;49(1):1–45. · DOI · Paper page
  28. Ornowska M, Wittmann J, Reynolds S. Central venous access device locking practices in the adult critical care setting: A single-centre, observational study establishing duration of locking per catheter lumen. Vasc Access J Can Vasc Access Assoc. 2022;16(2):10–21.
  29. Hemming K, Kasza J, Hooper R, Forbes A, Taljaard M. A tutorial on sample size calculation for multiple-period cluster randomized parallel, cross-over and stepped-wedge trials using the Shiny CRT Calculator. Int J Epidemiol. 2020;49(3):979–95. · DOI · Paper page
  30. Rothman KJ, Lash TL, VanderWeele TJ, Haneuse S. Modern epidemiology. 4th ed. Philadelphia: Wolters Kluwer; 2021.
  31. Shanmugasundaram S, Kubiak A, Dar A, Shrinet A, Chauhan N, Haque H, et al. High incidence of large bore temporary hemodialysis catheter malfunction in patients with COVID-19 related kidney injury. J Vasc Access. 2022:112972982110673. · DOI
  32. Kanitra JJ, Power AD, Hayward RD, Haouilou JC, Edhayan E. Malfunctioning temporary hemodialysis catheters in patients with novel coronavirus disease 2019. J Vasc Surg. 2021;73(6):1881–1888.e3. · doi:10.1016/j.jvs.2020.11.033
  33. Gidaro A, Vailati D, Gemma M, Lugli F, Casella F, Cogliati C, et al. Retrospective survey from vascular access team Lombardy net in COVID-19 era. J Vasc Access. 2021:1129729821997252. · DOI

Cited by

See all 10

Metadata

Authors
Ornowska, M., Wong, H., Ouyang, Y., Mitra, A., White, A., Willems, S., Wittmann, J., & Reynolds, S.
Venue
Trials
Published
2022-08-30
Volume
23
Issue
1
ISSN
1745-6215
Cited by
10
References
1
Language
en
Licence
Funders
  • CANHealth Network
  • Mitacs
  • Royal Columbian Hospital Foundation
  • SterileCare Inc.

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Control of Line Complications with KiteLock (CLiCK) in the critical care unit: study protocol for a multi-center, cluster-randomized, double-blinded, crossover trial investigating the effect of a novel locking fluid on central line complications in the critical care population. https://app.cochat.ai/papers/10.1186/s13063-022-06671-5
The paper
Ornowska, M., Wong, H., Ouyang, Y., Mitra, A., White, A., Willems, S., Wittmann, J., & Reynolds, S. (2022). Control of Line Complications with KiteLock (CLiCK) in the critical care unit: study protocol for a multi-center, cluster-randomized, double-blinded, crossover trial investigating the effect of a novel locking fluid on central line complications in the critical care population. Trials. https://doi.org/10.1186/s13063-022-06671-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.