Ultrasound-guided peripheral venous cannulation in critically ill patients: a practical guideline
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: Up to one-third of critically ill patients have difficult intravenous access (DIVA). This occurs often in obese patients, those with generalized edemas or in patients with previous venous cannulations. In DIVA patients, the conventional technique often fails. In contrast, ultrasound-guided cannulation has demonstrated a high success rate, improving patient satisfaction and even a reduction in the need of central venous lines. However, a high rate of premature catheter failure has been shown in cannulations performed by ultrasound guidance and thus a comprehensive knowledge of several aspects related to this procedure is mandatory to improve cannulation success, avoid complications and lengthen the survival of the catheter. Main text: Several practical issues related to peripheral venous cannulation are described: peripheral venous anatomy, vein size and catheter selection, distance from skin to vein, insertion angle and selection of the catheter length, cannulation technique itself (out-of-plane or in-plane) and checking catheter position. Conclusion: Key concepts regarding ultrasound-guided peripheral vein cannulation should be well known for practitioners, aiding in improving cannulation success and catheter dwell time, and avoiding complications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Costantino, T. G., Parikh, A. K., Satz, W. A., & Fojtik, J. P. (2005) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2004.12.026 · Cited by 435 · cited 1×
“Patient satisfaction also improves using US guidance [2].”
Method
Cited by
Management of difficult intravenous access: a qualitative review
Ng, M., Kwok Fai Mark, L., & Fatimah, L. (2022) · World Journal of Emergency Medicine · doi:10.5847/wjem.j.1920-8642.2022.104 · Cited by 37
Anderssen, L. M., Petersen, M. S., Wang, A. G., Mohr, M., & Fjallheim, A. S. (2026) · The Journal of Vascular Access · doi:10.1177/11297298251347816 · Cited by 11
“3,6,7 DIVA can be caused by different predictors, for example, dehydration, obesity, vascular pathology, chronic illness, edema, smaller veins, intravenous drug abuse, chemotherapy treatment, malnutrition, hypovolemia, diabetes, etc.”
Hansen, Ø. M., & Solbakken, R. (2024) · BMJ Open · doi:10.1136/bmjopen-2023-078106 · Cited by 10
“…such as point- of-care ultrasound (POCUS), is recommended when establishing peripheral intravenous access in patients with DIVA (figure 1), 10 30 and patients describe the insertion of ultrasound-guided peripheral intravenous catheters (USGPIVCs) as more comfortable than traditional landmark…”
Background
Metadata
- Authors
- Blanco, P.
- Venue
- The Ultrasound Journal
- Publisher
- Mattioli1885
- Published
- 2019-10-17
- Volume
- 11
- Issue
- 1
- Pages
- 27-27
- ISSN
- 2036-3176 (ISSN-L)
- 2524-8987
- OpenAlex
- W2980775802
- Cited by
- 60
- References
- 1
- FWCI
- 7.21
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasound-guided peripheral venous cannulation in critically ill patients: a practical guideline. https://app.cochat.ai/papers/10.1186/s13089-019-0144-5
- The paper
- Blanco, P. (2019). Ultrasound-guided peripheral venous cannulation in critically ill patients: a practical guideline. The Ultrasound Journal. https://doi.org/10.1186/s13089-019-0144-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.