CoChat

Management of the polyallergic patient with allergy immunotherapy: a practice-based approach

Open access
Demoly, Pascal, Passalacqua, Giovanni, Pfaar, Oliver, Sastre, Joaquin, Wahn, Ulrich · 2016 · Allergy, Asthma & Clinical Immunology
Cited by 96

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The great majority (60-80 %) of patients consulting specialist physicians for allergic respiratory disease are polysensitized and thus may be potentially clinically polyallergic. However, management approaches to allergen immunotherapy (AIT) in polysensitized and polyallergic patients are not standardized. METHODS: An international group of clinicians with in-depth expertise in AIT product development, clinical trials and clinical practice met to generate up-to-date, unambiguous, pragmatic guidance on AIT in polysensitized and polyallergic patients. The guidance was developed after reviewing (1) the current stance of regulatory bodies and learned societies, (2) the literature data on single- and multi-AIT and (3) the members' confirmed clinical experience with polysensitized patients. RESULTS: AIT is safe and effective in polysensitized and polyallergic patients, and should always be based on the identification of one or more clinically relevant allergens (based on the type and severity of symptoms, the duration of induced symptoms, the impact on quality of life and how difficult an allergen is to avoid). Single-AIT is recommended in polyallergic patients in whom one of the relevant allergens is nevertheless clearly responsible for the most intense and/or bothersome symptoms. Parallel 2-allergen immunotherapy or mixed 2-allergen immunotherapy is indicated in polyallergic patients in whom two causal relevant allergens have a marked clinical and QoL impact. In parallel 2-allergen immunotherapy (whether subcutaneous or sublingual), high-quality, standardized, single-allergen formulations must be administered with an interval of 30 min. Mixing of allergen extracts may be considered, as long as (1) the mixture is technically feasible, (2) the mixture is allowed from a regulatory standpoint, (3) the allergen doses are reduced in proportion to the number of components but are still at concentrations with demonstrated efficacy. CONCLUSIONS: Physicians can prescribe AIT (preferably with high-quality, standardized, single-allergen formulations) with confidence in polysensitized and polyallergic patients by focusing on clinical/QoL relevance and safety.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s13223-015-0109-6

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 96

Metadata

Authors
Demoly, P., Passalacqua, G., Pfaar, O., Sastre, J., & Wahn, U.
Venue
Allergy, Asthma & Clinical Immunology
Published
2016-01-11
Volume
12
Issue
1
Pages
2-2
ISSN
  • 1710-1484 (ISSN-L)
  • 1710-1492
OpenAlex
W2239045437
Cited by
96
References
10
FWCI
6.27
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.