Impact of acquisition time and penalizing factor in a block-sequential regularized expectation maximization reconstruction algorithm on a Si-photomultiplier-based PET-CT system for 18F-FDG

Open access
Trägårdh, Elin, Minarik, David, Almquist, Helén, Bitzén, Ulrika, Garpered, Sabine, Hvittfelt, Erland, Olsson, Berit, Oddstig, Jenny · 2019 · EJNMMI Research

The DOI matches its Crossref record; the references it cites are not checked yet.

Abstract

Block-sequential regularized expectation maximization (BSREM), commercially Q. Clear (GE Healthcare, Milwaukee, WI, USA), is a reconstruction algorithm that allows for a fully convergent iterative reconstruction leading to higher image contrast compared to conventional reconstruction algorithms, while also limiting noise. The noise penalization factor β controls the trade-off between noise level and resolution and can be adjusted by the user. The aim was to evaluate the influence of different β values for different activity time products (ATs = administered activity × acquisition time) in whole-body 18 F-fluorodeoxyglucose (FDG) positron emission tomography with computed tomography (PET-CT) regarding quantitative data, interpretation, and quality assessment of the images. Twenty-five patients with known or suspected malignancies, referred for clinical 18 F-FDG PET-CT examinations acquired on a silicon photomultiplier PET-CT scanner, were included. The data were reconstructed using BSREM with β values of 100–700 and ATs of 4–16 MBq/kg × min/bed (acquisition times of 1, 1.5, 2, 3, and 4 min/bed). Noise level, lesion SUV max , and lesion SUV peak were calculated. Image quality and lesion detectability were assessed by four nuclear medicine physicians for acquisition times of 1.0 and 1.5 min/bed position. The noise level decreased with increasing β values and ATs. Lesion SUV max varied considerably between different β values and ATs, whereas SUV peak was more stable. For an AT of 6 (in our case 1.5 min/bed), the best image quality was obtained with a β of 600 and the best lesion detectability with a β of 500. AT of 4 generated poor-quality images and false positive uptakes due to noise. For oncologic whole-body 18 F-FDG examinations on a SiPM-based PET-CT, we propose using an AT of 6 (i.e., 4 MBq/kg and 1.5 min/bed) reconstructed with BSREM using a β value of 500–600 in order to ensure image quality and lesion detection rate as well as a high patient throughput. We do not recommend using AT < 6 since the risk of false positive uptakes due to noise increases.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s13550-019-0535-4

Cites

Statistics

Figures

Fig. 1 a Noise level for all examined combinations of AT (MBq/kg × min/bed) and β values. All values are normalized to AT of 16 with a β of 300 (reference). The boxplots show the median (thick line in the middle of the boxes) and the first and third quartiles (the top and bottom box lines). The whiskers extend to 1.5 times the height of the box (approx. 95% of the data). Circles are outliers, and stars in the graph indicate extreme outliers. b β value versus administered activity × acquisition time (AT) (min/bed × MBq/kg). The β value for all patients at different AT to obtain the same noise level as for the reference image (AT of 16 with a β of 300) (a)
Fig. 1 a Noise level for all examined combinations of AT (MBq/kg × min/bed) and β values. All values are normalized to AT of 16 with a β of 300 (reference). The boxplots show the median (thick line in the middle of the boxes) and the first and third quartiles (the top and bottom box lines). The whiskers extend to 1.5 times the height of the box (approx. 95% of the data). Circles are outliers, and stars in the graph indicate extreme outliers. b β value versus administered activity × acquisition time (AT) (min/bed × MBq/kg). The β value for all patients at different AT to obtain the same noise level as for the reference image (AT of 16 with a β of 300) (a)CC BY · PubMed Central
Fig. 2 SUVmax (a) and SUVpeak (b) for all examined combinations of AT (MBq/kg × min/bed) and β values. All values are normalized to an AT of 16 with a β of 300 (reference). The same scale on the y-axis is used in order to highlight the smaller variation of SUVpeak compared with SUVmax. The boxplots show the median and the second and third quartile groups (box) whereas the whiskers show the first and the fourth quartile groups. Circles are outliers, and stars indicate extreme outliers
Fig. 2 SUVmax (a) and SUVpeak (b) for all examined combinations of AT (MBq/kg × min/bed) and β values. All values are normalized to an AT of 16 with a β of 300 (reference). The same scale on the y-axis is used in order to highlight the smaller variation of SUVpeak compared with SUVmax. The boxplots show the median and the second and third quartile groups (box) whereas the whiskers show the first and the fourth quartile groups. Circles are outliers, and stars indicate extreme outliersCC BY · PubMed Central
Fig. 3 Image quality (a) and lesion detectability (b) for the combinations of AT (min/bed × MBq/kg) and β values
Fig. 3 Image quality (a) and lesion detectability (b) for the combinations of AT (min/bed × MBq/kg) and β valuesCC BY · PubMed Central
Fig. 4 Example of a lesion (right adrenal gland, indicated by the arrow) and how it appears in the reference with an AT of 16 (4 MBq/kg and 4 min/bed position with a β of 300) and the combinations of time/bed position and β values evaluated
Fig. 4 Example of a lesion (right adrenal gland, indicated by the arrow) and how it appears in the reference with an AT of 16 (4 MBq/kg and 4 min/bed position with a β of 300) and the combinations of time/bed position and β values evaluatedCC BY · PubMed Central
Fig. 5 Example of a lesion in a vertebra not visible in the 4-min reference (upper left corner) but, to different degrees, visible in the other combinations of time/bed position and β values evaluated. The last row shows 1-min reconstructions from the 4-min acquisition for the last 3 min, where the lesion is not visible. OSEM+TOF with and without PSF are shown in the upper row
Fig. 5 Example of a lesion in a vertebra not visible in the 4-min reference (upper left corner) but, to different degrees, visible in the other combinations of time/bed position and β values evaluated. The last row shows 1-min reconstructions from the 4-min acquisition for the last 3 min, where the lesion is not visible. OSEM+TOF with and without PSF are shown in the upper rowCC BY · PubMed Central
Fig. 6 Example of a lesion in the liver not visible in the 4-min reference (upper left corner), to different degrees, visible in the other combinations of time/bed position and β values evaluated. The last row shows 1-min reconstructions from the 4-min acquisition for the last 3 min, where the lesion is not visible. OSEM+TOF with and without PSF are shown in the upper row
Fig. 6 Example of a lesion in the liver not visible in the 4-min reference (upper left corner), to different degrees, visible in the other combinations of time/bed position and β values evaluated. The last row shows 1-min reconstructions from the 4-min acquisition for the last 3 min, where the lesion is not visible. OSEM+TOF with and without PSF are shown in the upper rowCC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

The citation lists are queued

They are fetched later and appear here then.

References 20 · Cited by 50

Research works printed but not linked: 1

  1. Ross SQ. Clear, GE Healthcare. White paper; 2014.

Metadata

Authors
Trägårdh, E., Minarik, D., Almquist, H., Bitzén, U., Garpered, S., Hvittfelt, E., Olsson, B., & Oddstig, J.
Affiliations
  • Lund University (SE)
  • Skåne University Hospital (SE)
Corresponding author
Trägårdh, Elin
Venue
EJNMMI Research
Published
2019-07-24
Volume
9
Issue
1
Pages
64-64
ISSN
2191-219X (ISSN-L)
OpenAlex
W2964002309
Cited by
50
References
20
Citations by year
2026: 1 · 2025: 11 · 2024: 5 · 2023: 10 · 2022: 10 · 2021: 6 · 2020: 7
FWCI
3.80
Type
journal article
Language
en
Open access
Licence
Locations
  • EJNMMI Research (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Lund University Publications (Lund University) (submittedVersion)
Funders
  • Knut och Alice Wallenbergs Stiftelse (-)
  • Medicinska Fakulteten, Lunds Universitet (-)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
Keywords
BSREM, acquisition time, 18F-FDG PET/CT, silicon photomultipliers, iterative reconstruction, SUVmax, lesion detectability, image noise, false-positive uptake

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Impact of acquisition time and penalizing factor in a block-sequential regularized expectation maximization reconstruction algorithm on a Si-photomultiplier-based PET-CT system for 18F-FDG. https://app.cochat.ai/papers/10.1186/s13550-019-0535-4
The paper
Trägårdh, E., Minarik, D., Almquist, H., Bitzén, U., Garpered, S., Hvittfelt, E., Olsson, B., & Oddstig, J. (2019). Impact of acquisition time and penalizing factor in a block-sequential regularized expectation maximization reconstruction algorithm on a Si-photomultiplier-based PET-CT system for 18F-FDG. EJNMMI Research. https://doi.org/10.1186/s13550-019-0535-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.