Evaluating the OpenAI’s GPT-3.5 Turbo’s performance in extracting information from scientific articles on diabetic retinopathy
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
We aimed to compare the concordance of information extracted and the time taken between a large language model (OpenAI’s GPT-3.5 Turbo via API) against conventional human extraction methods in retrieving information from scientific articles on diabetic retinopathy (DR). The extraction was done using GPT3.5 Turbo as of October 2023. OpenAI’s GPT-3.5 Turbo significantly reduced the time taken for extraction. Concordance was highest at 100% for the extraction of the country of study, 64.7% for significant risk factors of DR, 47.1% for exclusion and inclusion criteria, and lastly 41.2% for odds ratio (OR) and 95% confidence interval (CI). The concordance levels seemed to indicate the complexity associated with each prompt. This suggests that OpenAI’s GPT-3.5 Turbo may be adopted to extract simple information that is easily located in the text, leaving more complex information to be extracted by the researcher. It is crucial to note that the foundation model is constantly improving significantly with new versions being released quickly. Subsequent work can focus on retrieval-augmented generation (RAG), embedding, chunking PDF into useful sections, and prompting to improve the accuracy of extraction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“Moreover, several studies have relied on LLMs to assess their own outputs (12, 14, 21–24), raising concerns about reliability and bias.”
From Performance of large language models and prompt engineering strategies for data extraction in systematic reviews (2026) · cites this paper as [21]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Earlier reports have shown that LLMs can markedly reduce data extraction time compared with manual approaches (17, 21, 24).”
From Performance of large language models and prompt engineering strategies for data extraction in systematic reviews (2026) · cites this paper as [21]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical guidelines: Potential benefits, limitations, and harms of clinical guidelines
Woolf, S. H., Grol, R., Hutchinson, A., Eccles, M., & Grimshaw, J. (1999) · BMJ · doi:10.1136/bmj.318.7182.527 · Cited by 2,548
Marshall, I. J., & Wallace, B. C. (2019) · Systematic Reviews · doi:10.1186/s13643-019-1074-9 · Cited by 638
Detecting Hallucinated Content in Conditional Neural Sequence GenerationPreprint
Zhou, C., Neubig, G., Gu, J., Diab, M. T., Guzmán, F. (., Zettlemoyer, L., & Ghazvininejad, M. (2020) · Findings · doi:10.48550/arxiv.2011.02593 · Cited by 242
The problems with systematic reviews: a living systematic review
Uttley, L., Quintana, D. S., Montgomery, P., Carroll, C., Page, M. J., Falzon, L., Sutton, A., & Moher, D. (2023) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2023.01.011 · Cited by 184
Detecting Hallucinated Content in Conditional Neural Sequence Generation
Zhou, C., Neubig, G., Gu, J., Diab, M., Guzmán, F., Zettlemoyer, L., & Ghazvininejad, M. (2021) · Findings of the Association for Computational Linguistics: ACL-IJCNLP 2021 · doi:10.18653/v1/2021.findings-acl.120 · Cited by 122
The Policy Role of Systematic Reviews: Past, Present and Future
Haddaway, N., & Pullin, A. S. (2014) · Springer Science Reviews · doi:10.1007/s40362-014-0023-1 · Cited by 107
Resource use during systematic review production varies widely: a scoping review
Nussbaumer-Streit, B., Ellen, M., Klerings, I., Sfetcu, R., Riva, N., Mahmić-Kaknjo, M., Poulentzas, G., Martinez, P., Baladia, E., Ziganshina, L. E., et al. (2021) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2021.05.019 · Cited by 98
Mancin, S., Sguanci, M. E., Andreoli, D., Soekeland, F., Anastasi, G., Piredda, M., & Marinis, M. G. D. (2023) · MethodsX · doi:10.1016/j.mex.2023.102532 · Cited by 96
A systematic review and meta-analysis on ChatGPT and its utilization in medical and dental research
Bagde, H. S., Dhopte, A., Alam, M. K., & Basri, R. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e23050 · Cited by 82
Enhancing title and abstract screening for systematic reviews with GPT-3.5 turbo
Gargari, O. K., Mahmoudi, M. H., Hajisafarali, M., & Samiee, R. (2023) · BMJ Evidence-Based Medicine · doi:10.1136/bmjebm-2023-112678 · Cited by 46
Cited by
Scherbakov, D., Hubig, N., Jansari, V., Bakumenko, A., & Lenert, L. A. (2024) · arXiv · doi:10.48550/arxiv.2409.04600 · Cited by 156
Scherbakov, D., Hubig, N., Jansari, V., Bakumenko, A., & Lenert, L. A. (2025) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocaf063 · Cited by 154
Enhancing medical AI with retrieval-augmented generation: A mini narrative review
Gargari, O. K., & Habibi, G. (2025) · Digital Health · doi:10.1177/20552076251337177 · Cited by 178
Evaluating Large Language Models in Ophthalmology: Systematic Review
Zhang, Z., Zhang, H., Pan, Z., Bi, Z., Wan, Y., Song, X., & Fan, X. (2025) · Journal of Medical Internet Research · doi:10.2196/76947 · Cited by 48
Ferroptosis: a novel mechanism of cell death in ophthalmic conditions
Yang, Y., Lin, Y., Han, Z., Wang, B., Zheng, W., & Wei, L. (2024) · Frontiers in Immunology · doi:10.3389/fimmu.2024.1440309 · Cited by 46
Metadata
- Authors
- Gue, C. C. Y., Rahim, N. D. A., Rojas-Carabali, W., Agrawal, R., RK, P., Abisheganaden, J., & Yip, W. F.
- Affiliations
- National Healthcare Group (SG)
- Nanyang Technological University (SG)
- Corresponding author
- Yip, Wan Fen
- Venue
- Systematic Reviews
- Published
- 2024-05-16
- Volume
- 13
- Issue
- 1
- Pages
- 135-135
- ISSN
- 2046-4053 (ISSN-L)
- PMC
- PMC11097400
- OpenAlex
- W4396959345
- Cited by
- 31
- References
- 9
- Citations by year
- 2026: 14 · 2025: 13 · 2024: 4
- FWCI
- 26.99
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Systematic Reviews (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Social Sciences › General Social Sciences › Computational and Text Analysis Methods
- Physical Sciences › Computer Science › Artificial Intelligence › Topic Modeling
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Keywords
- GPT-3.5-turbo, large language models, automatic information extraction, diabetic retinopathy, scientific articles, risk factors, study inclusion and exclusion criteria, prompt engineering, retrieval-augmented generation
- MeSH terms
- Diabetic Retinopathy, Humans, Natural Language Processing, Information Storage and Retrieval, Data Mining
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluating the OpenAI’s GPT-3.5 Turbo’s performance in extracting information from scientific articles on diabetic retinopathy. https://app.cochat.ai/papers/10.1186/s13643-024-02523-2
- The paper
- Gue, C. C. Y., Rahim, N. D. A., Rojas-Carabali, W., Agrawal, R., RK, P., Abisheganaden, J., & Yip, W. F. (2024). Evaluating the OpenAI’s GPT-3.5 Turbo’s performance in extracting information from scientific articles on diabetic retinopathy. Systematic Reviews. https://doi.org/10.1186/s13643-024-02523-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.