Efficacy of disinfectant-impregnated wipes used for surface disinfection in hospitals: a review
Open accessThe DOI matches its Crossref record; 82 of the 82 references it cites were found in a registry or an index; 23 of the 85 sources its claims cite were checked for support.
Abstract
Ready-to-use disinfecting wipes are increasingly used in hospitals because of convenient implementation and reliable performance, though efficacy depends on multiple variables.
Overview
CoChat Summary
TL;DR
This review summarizes variables affecting disinfectant-impregnated wipe (DIW) efficacy in hospital surface disinfection, emphasizing interactions between wipe materials and active ingredients, especially QAC adsorption onto cotton, as a major cause of disinfection failure. It also critiques current efficacy test standards and concludes that more clinically relevant studies and improved standards are needed.
Key findings
- DIW performance depends on disinfectant type/concentration, wipe material/construction, application method, wiping strategy, storage time, and wipe–disinfectant interaction; the interaction between disinfectant and textile substrate is described as the biggest encumbrance to disinfection performance.
- QACs are the most commonly used disinfectant in wipes, but adsorption onto cotton substrate can reduce active-ingredient concentration and lead to disinfection failure; later work cited in the review found quats adsorption onto cotton can be minimized while maintaining efficacy against *Pseudomonas aeruginosa* and *Staphylococcus aureus*.
- Application methods differ substantially: “Dip and Wipe” uses a 5–10 s dip, “Soak and Wipe” uses 10 min up to 8 h soaking, and ready-to-use disinfecting wipes are pre-wetted with shelf life up to 1 month (can be longer); RTUDW is recommended for compliance, employee time, and costs, but storage may reduce antimicrobial activity and efficacy can decrease on larger wiped surface areas.
- Current standards have key drawbacks: EN 16615 is considered most suitable for DIWs but uses a fixed 16 ml disinfectant volume and PVC/PUR surface with contact time 1–60 min; ASTM E2967–15 uses a Wiperator with 5–45 s contact time on stainless steel; standards generally cannot differentiate mechanical removal of inoculum from chemical inactivation and may yield divergent outcomes.
Methods
- A systematic literature search was conducted via Google Scholar across five categories: wipes, disinfectants, application methods, interaction between wipes and active ingredients, and wiping strategy; clinical efficacy studies were searched from the National Center for Biotechnology Information database.
- Standards and guidelines were reviewed from CEN TC 216, US EPA OPP with AOAC International and ASTM International, ECHA, and CDC/HICPAC.
- Data were extracted by two authors from titles and abstracts obtained from Google Scholar and PubMed; one author checked abstracts against criteria, and full articles deemed necessary were obtained and reviewed by another author.
Limitations
- Stated in the paper: less is known about DIW effectiveness in decontamination; there is no clear understanding of the interaction phenomenon; more studies of DIW disinfection efficacy in clinical practice are needed; and current standards have drawbacks, so one can hardly advocate for DIW use in hospitals.
- Stated in the paper: efficacy standards cannot differentiate mechanical removal from chemical inactivation, need more realistic disinfectant volume per unit surface area, and may produce divergent outcomes; a guideline for comparable results between standards is needed.
- Evident from the text: despite calling the search systematic, the review reports no search strings, date limits, inclusion/exclusion criteria, number of records screened, or quality appraisal, and it provides no quantitative synthesis; the authors also note design limitations in several included studies, such as lack of microbiological tests, use of saline instead of neutralizer, or failure to test wipes in field use.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
15 Valid · 4 Not valid · 35 Not checked · 32 Own results and interpretations
Every source the paper cites for this claim was checked and supports it.
In the paper
“In 2007, Williams et al. developed a three-step protocol to quantify the efficacy of disinfectant wipes, their ability to remove and prevent the microbial transfer from surfaces and their overall antimicrobial activity, which could be considered as a milestone for the”
§ Efficacy of disinfectant-impregnated wipes used for surface disinfection in hospitals: a review > Results and discussion > Efficacy studies in literature
What the sources say
- Supportedcites [29] Williams GJ Denyer SP Hosein IK Hill DW Maillard JY The development of a new three-step protocol to determine the efficacy of disinfectant wipes on surfaces contaminated with Staphylococcus aureus J Hosp Infect 2007 67 329 335 10.1016/j.jhin.2007.08.012 17945392 source
The Summary states that the authors developed a three-step protocol to quantify wipe efficacy, removal and prevention of microbial transfer, and overall antimicrobial activity. The Introduction specifies the same three assessments. (LLM, conf=0.95)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources that could be checked couldn’t confirm or dispute this claim.
In the paper
“numerous studies showed that the adsorption of QACs onto the cotton substrate wiping material could lead to the failure of the disinfection process [47, 52–58].”
§ Efficacy of disinfectant-impregnated wipes used for surface disinfection in hospitals: a review > Results and discussion > Disinfectant
What the sources say
- Not checked — no full text of the sourcecites [47] Wessels S Ingmer H Modes of action of three disinfectant active substances: a review Regul Toxicol Pharmacol 2013 67 456 467 10.1016/j.yrtph.2013.09.006 24080225 source
- Not checked — no full text of the sourcecites [52] Hinchliffe DJ Condon BD Slopek RP Reynolds M The adsorption of alkyl-dimethyl-benzyl-ammonium chloride onto cotton nonwoven hydroentangled substrates at the solid–liquid interface is minimized by additive chemistries Text Res J 2016 87 70 80 10.1177/0040517515622154 source
- Not checked — no full text of the sourcecites [53] Tezel U Pavlostathis SG Role of quaternary ammonium compounds on antimicrobial resistance in the environment. Antimicrobial Resistance in the Environment 2011 349 387 source
- Not checked — no full text of the sourcecites [54] Gerba CP Müller V Quaternary ammonium biocides: efficacy in application Appl Environ Microbiol 2015 81 464 469 10.1128/AEM.02633-14 25362069 PMC4277564 source
- Not checked — no full text of the sourcecites [55] Jennings MC Minbiole KPC Wuest WM Quaternary ammonium compounds: an antimicrobial mainstay and platform for innovation to address bacterial resistance ACS Infect Dis 2015 1 288 303 10.1021/acsinfecdis.5b00047 27622819 source
- Not checked — no full text of the sourcecites [56] Møretrø T Heir E Nesse LL Vestby LK Langsrud S Control of Salmonella in food related environments by chemical disinfection Food Res Int 2012 45 532 544 10.1016/j.foodres.2011.02.002 source
- Could not verifycites [57] Ghanbar S Kazemian MR Liu S New generation of N-chloramine/QAC composite biocides: efficient antimicrobial agents to target antibiotic-resistant Bacteria in the presence of organic load ACS Omega 2018 3 9699 9709 10.1021/acsomega.8b00675 PMC6644430 31459099 sourceExperimental — accuracy not yet measured
The Discussion (page unavailable) reports that QACs can bind to proteins in an organic load and lose antimicrobial activity. Our copy does not address adsorption onto cotton wiping material or disinfection failure caused by such adsorption (searched: cotton, wiping material, QAC adsorption). (LLM, conf=0.76)
- Could not verifycites [58] Jiao Y L-n N Ma S Li J Tay FR J-h C Quaternary ammonium-based biomedical materials: state-of-the-art, toxicological aspects and antimicrobial resistance Prog Polym Sci 2017 71 53 90 10.1016/j.progpolymsci.2017.03.001 PMC7111226 32287485 sourceExperimental — accuracy not yet measured
The Sutures and wound dressings section (page unavailable) discusses antibacterial cotton treated with quaternary ammonium compounds, not cotton wipes adsorbing disinfectant. A search for cotton wiping material and QAC adsorption found no passage in our copy linking adsorption onto wipes to disinfection failure. (LLM, conf=0.72)
hedgedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“RTUDW is disposable, which eliminates the possible contaminations and transfer of pathogen due to towelettes reuse [64].”
§ Efficacy of disinfectant-impregnated wipes used for surface disinfection in hospitals: a review > Results and discussion > Application method
What the sources say
- Partly supportedcites [64] Tebbutt G. M. Laboratory evaluation of disposable and reusable disinfectant cloths for cleaning food contact surfaces Epidemiology and Infection 1988 101 2 367 375 10.1017/S0950268800054315 3141202 PMC2249377 sourceExperimental — accuracy not yet measured
The Discussion says disposable wipes would considerably reduce the risk of cross-contamination associated with reusable cloths. It does not say they eliminate that risk, and the paper evaluates disposable alcohol wipes rather than RTUDW specifically. Page numbers were not provided in our copy. (LLM, conf=0.88)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“The result implicates a larger wiping surface area may lead to decreased bactericidal efficacy.”
§ Efficacy of disinfectant-impregnated wipes used for surface disinfection in hospitals: a review > Results and discussion > Wiping strategy
What the sources say
- Supportedcites [74] West AM, Nkemngong CA, Voorn MG, Wu T, Li X, Teska PJ, et al. Surface area wiped, product type, and target strain impact bactericidal efficacy of ready-to-use disinfectant Towelettes. Antimicrob Resist Infect Control. 2018;7:1–8. PMC6180426 30338060 source
The Abstract conclusion states that wiping larger surface areas may decrease bactericidal efficacy. The Discussion likewise reports higher bacterial reductions when wiping one or two square feet than when wiping eight square feet, while noting that the extent of the effect depends on the product. (LLM, conf=0.95)
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources that could be checked couldn’t confirm or dispute this claim.
In the paper
“the longer storage time could increase the probability of losing antimicrobial activity due to the possible binding of active ingredients onto the towelettes or by the degradation of the active ingredient [73].”
§ Efficacy of disinfectant-impregnated wipes used for surface disinfection in hospitals: a review > Results and discussion > Application method
What the sources say
- Could not verifycites [73] Cadnum JL Hurless KN Kundrapu S Donskey CJ Transfer of Clostridium difficile spores by nonsporicidal wipes and improperly used hypochlorite wipes practice + product = perfection Infect Control Hosp Epidemiol 2015 34 441 442 10.1086/669871 23466922 sourceExperimental — accuracy not yet measured
The methods and findings (pp. 441–442) compare fresh wipes with wipes that dried during use, not wipes kept in storage. The paper does not address longer storage time, binding of active ingredients to towelettes, or ingredient degradation; searches for those terms found no supporting passage. (LLM, conf=0.78)
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Could not verify
30 more claims · 4 with their cited sources checked
Create a free account to see all 86 claims and every source verdict.
- It may state two separate claims as one. 31
- Probably not a substantial claim. 26
Citations
Cites
Estimating Health Care-Associated Infections and Deaths in U.S. Hospitals, 2002
Klevens, R. M., Edwards, J. R., Richards, C. L., Horan, T. C., Gaynes, R. P., Pollock, D. A., & Cardo, D. M. (2007) · Public Health Reports® · doi:10.1177/003335490712200205 · Cited by 2,960
How long do nosocomial pathogens persist on inanimate surfaces? A systematic review
Kramer, A., Schwebke, I., & Kampf, G. (2006) · BMC Infectious Diseases · doi:10.1186/1471-2334-6-130 · Cited by 2,504
Weber, D. J., Rutala, W. A., Miller, M. B., Huslage, K., & Sickbert-Bennett, E. (2010) · American Journal of Infection Control · doi:10.1016/j.ajic.2010.04.196 · Cited by 768 · cited 1×
“shed by patients can 42 contaminate hospital surfaces at concentrations sufficient for transmission, surviving for extended 43 periods and persisting despite attempts to remove them [5-11].”
Dancer, S. J. (2014) · Clinical Microbiology Reviews · doi:10.1128/cmr.00020-14 · Cited by 679 · cited 5×
“play a key role in preventing cross-contamination [12, 13] and spread 46 of HCAIs [14-19].”
InfluentialThe Role Played by Contaminated Surfaces in the Transmission of Nosocomial Pathogens
Otter, J. A., Yezli, S., & French, G. L. (2011) · Infection Control & Hospital Epidemiology · doi:10.1086/660363 · Cited by 670 · cited 2×
“shed by patients can 42 contaminate hospital surfaces at concentrations sufficient for transmission, surviving for extended 43 periods and persisting despite attempts to remove them [5-11].”
Jennings, M. C., Minbiole, K. P. C., & Wuest, W. M. (2015) · ACS Infectious Diseases · doi:10.1021/acsinfecdis.5b00047 · Cited by 651
Jiao, Y., Niu, L.-N., Ma, S., Li, J., Tay, F. R., & Chen, J.-H. (2017) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2017.03.001 · Cited by 639
Weinstein, R. A., & Hota, B. (2004) · Clinical Infectious Diseases · doi:10.1086/424667 · Cited by 635 · cited 5×
“play a key role in preventing cross-contamination [12, 13] and spread 46 of HCAIs [14-19].”
InfluentialOtter, J. A., Yezli, S., Salkeld, J. A. G., & French, G. L. (2013) · American Journal of Infection Control · doi:10.1016/j.ajic.2012.12.004 · Cited by 594 · cited 1×
“shed by patients can 42 contaminate hospital surfaces at concentrations sufficient for transmission, surviving for extended 43 periods and persisting despite attempts to remove them [5-11].”
The role of the surface environment in healthcare-associated infections
Weber, D. J., Anderson, D., & Rutala, W. A. (2013) · Current Opinion in Infectious Diseases · doi:10.1097/qco.0b013e3283630f04 · Cited by 567 · cited 1×
“shed by patients can 42 contaminate hospital surfaces at concentrations sufficient for transmission, surviving for extended 43 periods and persisting despite attempts to remove them [5-11].”
Research works printed but not linked: 5
- Amy G Bull R Craun GF Pegram R Siddiqui M Organization WH Disinfectants and disinfectant by-products 2000
- Edana I Edana I Guidelines for assessing the Flushability of disposable nonwoven products 2013 Brussels European Disposables and Nonwovens Association, Association of the Nonwoven Fabrics Industry
- Wenger M. Join the A-team: exploring the key role nurses play in antimicrobial stewardship. Can J Crit Care Nurs. 2017;28:50–50.
- Ecolab Quat Absorption Onto Textiles ECOLAB 2010 8
- Agency USEP Production performance test guidelines OCSPP 8102200: Disinfectants for Use on Hard Surface - Efficacy Data Recommendations: Office of Chemical Safety and Pollution Prevention (7510P), EPA 2012
Cited by
Wong, J., Goh, Q. Y., Tan, Z., Lie, S. A., Tay, Y. C., Ng, S. Y., & Soh, C. R. (2020) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-020-01620-9 · Cited by 695
“Quaternary ammonium compounds have good cleaning and deodorization properties with a broad spectrum of biocidal and sporostatic activity, including against lipid-enveloped viruses such as coronaviruses.(69)”
BackgroundHand Sanitizers: A Review on Formulation Aspects, Adverse Effects, and Regulations
Jing, J. L. J., Pei Yi, T., Bose, R. J. C., McCarthy, J. R., Tharmalingam, N., & Madheswaran, T. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17093326 · Cited by 325
Lie, S. A., Wong, S. W., Wong, L. T., Wong, T. G. L., & Chong, S. Y. (2020) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-020-01637-0 · Cited by 185
“The ultrasound machine should be wiped down with quaternary ammonium chloride disinfectant wipes.(40) It should then be left in the OR for ultraviolet C irradiation or hydrogen peroxide vaporization before it is used on another patient.”
MethodChen, B., Han, J., Dai, H., & Jia, P. (2021) · Environmental Pollution · doi:10.1016/j.envpol.2021.117074 · Cited by 161
A comprehensive review of automatic cleaning systems of solar panels
Derakhshandeh, J. F., AlLuqman, R., Mohammad, S., AlHussain, H., AlHendi, G., AlEid, D., & Ahmad, Z. (2021) · Sustainable Energy Technologies and Assessments · doi:10.1016/j.seta.2021.101518 · Cited by 182
New Clinical Applications of Electrolyzed Water: A Review
Yan, P., Daliri, E. B., & Oh, D. (2021) · Microorganisms · doi:10.3390/microorganisms9010136 · Cited by 141
Assadian, O., Harbarth, S., Vos, M. D., Knobloch, J. K. ‐., Asensio, Á., & Widmer, A. F. (2021) · Journal of Hospital Infection · doi:10.1016/j.jhin.2021.03.010 · Cited by 154
Morris, H. L., & Murray, R. K. (2020) · Textile Progress · doi:10.1080/00405167.2020.1824468 · Cited by 111
Disinfection and Sterilization in Health Care Facilities
Rutala, W. A., & Weber, D. J. (2021) · Infectious Disease Clinics of North America · doi:10.1016/j.idc.2021.04.004 · Cited by 119
Hamouda, T., Ibrahim, H., Kafafy, H. H. A. M., Mashaly, H., Mohamed, N. H., & Aly, N. M. (2021) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2021.04.071 · Cited by 89
“Surfaces disinfection wipes play an essential role in infection control, since their usage assists in removing the organic debris and microorganisms through the mechanical action of wiping along with the microbicidal action resulted from the disinfectant solution released by the wipes on the hard surface [5,6].”
Sjahro, N., Yunus, R. B., Abdullah, L. C., Rashid, S. B. A., Asis, A. J., & Akhlisah, Z. N. (2021) · Cellulose · doi:10.1007/s10570-021-03985-6 · Cited by 79
“These active agents may comprise a variety of biocides, such as triclosan, chitosan, polyphenols, some metal oxides, quaternary ammonium compounds (QACs), and chlorine (Sain, 2019; Song et al. 2019).”
BackgroundMuthuvelu, K. S., Ethiraj, B., Pramnik, S., Raj, N. K., Venkataraman, S., Rajendran, D. S., Bharathi, P., Palanisamy, E., Narayanan, A. S., Vaidyanathan, V. K., et al. (2023) · Food Science and Biotechnology · doi:10.1007/s10068-023-01336-8 · Cited by 97
“However, it can corrode metal, is naturally inactivated by organic matter, and causes irritation to the skin, eyes, and mucous membranes (Song et al., 2019).”
BackgroundInfluentialDisinfection, sterilization and antisepsis: An overview
Rutala, W. A., Boyce, J. M., & Weber, D. J. (2023) · American Journal of Infection Control · doi:10.1016/j.ajic.2023.01.001 · Cited by 102
Back to Basics: Choosing the Appropriate Surface Disinfectant
Artasensi, A., Mazzotta, S., & Fumagalli, L. (2021) · Antibiotics · doi:10.3390/antibiotics10060613 · Cited by 100
Bäumler, W., Eckl, D. B., Holzmann, T., & Schneider‐Brachert, W. (2021) · Critical Reviews in Microbiology · doi:10.1080/1040841x.2021.1991271 · Cited by 78
“Various measures are applied to reduce the number of MoV on surfaces like surface cleaning as well as physical and chemical disinfection procedures (Rutala and Weber 2019; Song et al. 2019).”
Advancements in Antimicrobial Textiles: Fabrication, Mechanisms of Action, and Applications
Orasugh, J. T., Temane, L. T., Pillai, S. K., & Ray, S. S. (2025) · ACS Omega · doi:10.1021/acsomega.4c11356 · Cited by 84
Comparative analysis of peracetic acid (PAA) and permaleic acid (PMA) in disinfection processes
Pironti, C., Dell’Annunziata, F., Giugliano, R., et al. (2021) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2021.149206 · Cited by 40
Boyce, J. M. (2024) · Antimicrobial Resistance and Infection Control · doi:10.1186/s13756-024-01461-x · Cited by 68
“Pre-impregnated disinfectant wipes have been shown to be effective in reducing total colony counts and MDRO bioburden on surfaces [218, 224–227].”
BackgroundA review of wipes used to disinfect hard surfaces in health care facilities
Boyce, J. M. (2020) · American Journal of Infection Control · doi:10.1016/j.ajic.2020.06.183 · Cited by 46
Maloney, B. P., McKerlie, T., Nasir, M., Murphy, C., Moi, M., Mudalige, P. K. G., Naser, N. E., & Duane, B. G. (2022) · Journal of Hospital Infection · doi:10.1016/j.jhin.2022.09.006 · Cited by 35
Song, X., Cvelbar, U., Stražar, P., Vossebein, L., & Zille, A. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b18746 · Cited by 24
Self-citationEnvironmental cleaning and disinfection of hospital rooms: A nationwide survey
Han, Z., Pappas, E. J., Simmons, A., Fox, J., Donskey, C. J., & Deshpande, A. (2020) · American Journal of Infection Control · doi:10.1016/j.ajic.2020.08.008 · Cited by 27
Warren, B. G., Barrett, A., Graves, A. M., King, C., Turner, N., & Anderson, D. J. (2022) · JAMA Network Open · doi:10.1001/jamanetworkopen.2022.42131 · Cited by 35
“(%) (N = 50) Sex Female 24 (48) Male 26 (52) Age, median (IQR), y 61 (45-69) Hospitalized in past 90 d 23 (46) Contact isolation 50 (100) Length of stay at enrollment, median (IQR), d 20 (9-57) Length of stay in study room at enrollment, median (IQR), d 6 (3-15) Active infection 50 (100) Blood 16 (32) Urine 12 (24) Ti…”
BackgroundCutts, T. A., Robertson, C., Theriault, S., Nims, R. W., Kasloff, S., Rubino, J. R., & Ijaz, M. K. (2020) · Frontiers in Public Health · doi:10.3389/fpubh.2020.00183 · Cited by 22
An alternative approach for the decontamination of hospital settings
Moccia, G., Motta, O., Pironti, C., Proto, A., Capunzo, M., & Caro, F. D. (2020) · Journal of Infection and Public Health · doi:10.1016/j.jiph.2020.09.020 · Cited by 31
Silva, E. P. D., Sit, G., Goldberg, M., Leynaert, B., Nadif, R., Ribet, C., Roche, N., Zins, M., Varraso, R., Dumas, O., et al. (2022) · Indoor Air · doi:10.1111/ina.13078 · Cited by 34
Goodarzi, R., Yousefimashouf, R., Taheri, M., Nouri, F., & Asghari, B. (2021) · Molecular Biology Reports · doi:10.1007/s11033-021-06533-4 · Cited by 20
Jurema, A. L. B., Rocha, R. S., Mailart, M. C., de Souza, M. Y., Gonçalves, S. E. D. P., Caneppele, T. M. F., & Bresciani, E. (2020) · Brazilian Dental Science · doi:10.14295/bds.2020.v23i2.2256 · Cited by 20
“Nevertheless, there is no consensus in the literature regarding this effectiveness, since some solutions can evaporate from the wipe and the biocide activity could be compromised [55].”
BackgroundNavarathna, T., Jinadatha, C., Corona, B. A., et al. (2023) · American Journal of Infection Control · doi:10.1016/j.ajic.2023.05.003 · Cited by 19
The impact of cleaning on the microbiomes of indoor surfaces
Täubel, M., Castagnoli, E., Salthammer, T., Morawska, L., & Salonen, H. (2024) · Indoor Environments · doi:10.1016/j.indenv.2024.100021 · Cited by 33
Sensitivity of SARS-CoV-2 towards Alcohols: Potential for Alcohol-Related Toxicity in Humans
Basak, D., & Deb, S. (2021) · Life · doi:10.3390/life11121334 · Cited by 18
Ding, X., Jiang, J., Tasoglou, A., et al. (2023) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxac096 · Cited by 17
Fomite transmission and disinfection strategies for SARS-CoV-2 and related virusesPreprint
Castaño, N., Cordts, S. C., Jalil, M. K., Zhang, K. S., Koppaka, S., Bick, A., Paul, R., & Tang, S. K. Y. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2005.11443 · Cited by 16
Markers of Chemical and Microbiological Contamination of the Air in the Sport Centers
Szulc, J., Okrasa, M., Ryngajłło, M., Pielech‐Przybylska, K., & Gutarowska, B. (2023) · Molecules · doi:10.3390/molecules28083560 · Cited by 18
Use of Hand Sanitizers in COVID-19 Prevention: A Comprehensive Overview
Vuppu, S., Mishra, T., & Chinamgari, A. (2023) · Pharmacoepidemiology · doi:10.3390/pharma2030022 · Cited by 31
Murashevych, B. V., Stepanskyi, D., Toropin, V., Mironenko, A. P., Sergiivna, M. H., Бурмистров, К. С., & Teteriuk, N. (2022) · Journal of Bioactive and Compatible Polymers · doi:10.1177/08839115221121852 · Cited by 13
Reboux, M., Chavignon, M., Tristan, A., Plaisant, F., Laurent, F. J., & Butin, M. (2023) · Antimicrobial Resistance and Infection Control · doi:10.1186/s13756-023-01226-y · Cited by 17
“Indeed, chemical disinfection is known to damage surfaces that become porous and more difficult to clean [27].”
BackgroundCan photocatalysis help in the fight against COVID-19 pandemic?
Markowska‐Szczupak, A., Paszkiewicz, O., Yoshiiri, K., Wang, K., & Kowalska, E. (2023) · Current Opinion in Green and Sustainable Chemistry · doi:10.1016/j.cogsc.2023.100769 · Cited by 13
Mali, M., Salem, K. S., Sarder, R., Agate, S., Mathur, K., & Pal, L. (2024) · Sustainability · doi:10.3390/su16041586 · Cited by 13
Martino, G. D., Pasqua, S., Douradinha, B. G., Monaco, F., Bartolo, C. D., Conaldi, P. G., & D’Apolito, D. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18020779 · Cited by 20
Avicenna, S., Nurhasanah, I., & Khumaeni, A. (2021) · Indonesian Journal of Chemistry · doi:10.22146/ijc.60344 · Cited by 11
Zeinali, A., & Platt, L. S. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.113179 · Cited by 16
Cross-contamination by disinfectant towelettes varies by product chemistry and strain
Voorn, M. G., Goss, S., Nkemngong, C. A., Li, X., Teska, P. J., & Oliver, H. F. (2020) · Antimicrobial Resistance and Infection Control · doi:10.1186/s13756-020-00797-4 · Cited by 10
Galaly, A. R., Ahmed, O. B., & Asghar, A. H. (2021) · Physics of Fluids · doi:10.1063/5.0046812 · Cited by 9
Rozman, U., Duh, D., Cimerman, M., & Turk, S. Š. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph192214690 · Cited by 10
Nonwoven materials and technologies for medical applications
Song, X., Melro, L., Padrão, J., Ribeiro, A. I., Yu, L., & Zille, A. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-90479-7.00008-7 · Cited by 11
Self-citationDetection, survival, and persistence of Staphylococcus capitis NRCS-A in neonatal units in England
Moore, G., Barry, A., Carter, J., Ready, J., Wan, Y., Elsayed, M. E., Haill, C., Khashu, M., Williams, O. M., Brown, C. S., et al. (2023) · Journal of Hospital Infection · doi:10.1016/j.jhin.2023.06.030 · Cited by 9
Tyski, S. S., Grzybowska, W., & Bocian, E. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18115932 · Cited by 9
Oliveira, F. O., dos Santos, L. M. C., da Silva, E. S., Rodrigues, L. D. A. P., Neves, P. R. F., Moreira, G. A. F., Lobato, G. M., Nascimento, C., Gerhardt, M., Santos, A. Á. B., et al. (2022) · Ozone Science and Engineering · doi:10.1080/01919512.2022.2040353 · Cited by 10
“A thorough review on efficacy of surface disinfection stated that active ingredients on the textile substrate may directly impact decontamination (Song, Vossebein, and Zille 2019).”
BackgroundMechanical Wiping Increases the Efficacy of Liquid Disinfectants on SARS-CoV-2
Sloan, A. M., Kasloff, S., & Cutts, T. A. (2022) · Frontiers in Microbiology · doi:10.3389/fmicb.2022.847313 · Cited by 11
Asghar, M. U., Ain, N. U., Zaidi, A., & Tariq, M. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e22120 · Cited by 10
Han, X., Song, M., Yu, Q., Zhou, J., Hu, H., Jiang, Y., Shi, Q., Chen, Y., Yang, Q., Du, X., et al. (2025) · International Journal of Antimicrobial Agents · doi:10.1016/j.ijantimicag.2025.107532 · Cited by 10
Cutts, T. A., Kasloff, S., Krishnan, J., Nims, R. W., Theriault, S., Rubino, J. R., & Ijaz, M. K. (2021) · Frontiers in Public Health · doi:10.3389/fpubh.2021.657443 · Cited by 8
Chavignon, M., Kolenda, C., Médina, M., Bonhomme, M., Blazere, L., Legendre, T., Tristan, A., Laurent, F. J., & Butin, M. (2022) · Frontiers in Cellular and Infection Microbiology · doi:10.3389/fcimb.2022.1060825 · Cited by 9
“Secondly, conventional disinfectants have a corrosive effect on abiotic surfaces (Song et al., 2019).”
BackgroundUltraviolet-C-Based Mobile Phone Sanitisation for Global Public Health and Infection Control
Olsen, M., Goldsworthy, A., Nassar, R., et al. (2023) · Microorganisms · doi:10.3390/microorganisms11081876 · Cited by 7
Borji, S., Rostamian, M., Kadivarian, S., et al. (2022) · GERMS · doi:10.18683/germs.2022.1340 · Cited by 7
Jennings, J., James, D., Wares, K. D., Campbell-Train, A., & Siani, H. (2024) · Journal of Hospital Infection · doi:10.1016/j.jhin.2024.04.023 · Cited by 7
Asghar, M. U., Zaidi, A., Tariq, M., & Ain, N. U. (2025) · Scientific Reports · doi:10.1038/s41598-025-12736-7 · Cited by 6
“In comparison, conventional chemical-based disinfectant wipes typically maintain efficacy for up to one month under similar conditions 54 .”
Bai, Y., Zhou, Y., Chang, R., Hu, X., Zhou, Y., Chen, J., Zhi, Z., & Yao, J. (2023) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2023.169146 · Cited by 7
Sterilization and Disinfection: Ensuring Infection Control in Dental Practices
Marín, N. P., García, L. D. V., López, E. C. A., Medina‐Solís, C. E., Zumarán, A. M., Rider, R. M., Márquez‐Preciado, R., García, P. R., & Orozco, M. F. S. (2025) · Cureus · doi:10.7759/cureus.79041 · Cited by 13
“However, it is highly inflammable, corrosive to metals, and lacks efficacy in the presence of organic dirt [9].”
InfluentialKrishnan, S., Venkatachalam, P., Shanmugam, S. R., & Nithyanand, P. (2025) · Journal of Medical Microbiology · doi:10.1099/jmm.0.001980 · Cited by 7
COVID-19 SALGININDA AMELİYATHANE VE VAKA YÖNETİMİ
Çelik, B., Yasak, K., Damar, H. T., Umar, D. Ç., & Öğce, F. (2020) · Journal of Anatolia Nursing and Health Sciences · doi:10.17049/ataunihem.728544 · Cited by 9
Infection Control for Perioperative Ultrasonography and Echocardiography
Desai, S. R., Tang, L., & Hwang, N. C. (2022) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2022.08.008 · Cited by 8
He, H., Liou, S.-Y., Shimabuku, K. K., Zhou, P., Choi, Y., Meschke, J. S., Roberts, M. C., Lee, Y., & Dodd, M. C. (2025) · Environmental Science & Technology · doi:10.1021/acs.est.4c10223 · Cited by 7
He, Y., Liang, B., Mai, J., Lan, F., Xiong, Z., Liu, X., Yang, K., Liu, X., Liu, S., Zhao, Z., et al. (2024) · Microbial Pathogenesis · doi:10.1016/j.micpath.2024.107114 · Cited by 6
Chaudhary, N. K., Guragain, B., Rai, S., Chaudhary, N., Chaudhary, R., Sachin, K. M., Lamichhane-Khadka, R., & Bhattarai, A. (2021) · Tenside Surfactants Detergents · doi:10.1515/tsd-2020-2314 · Cited by 7
Inactivation of SARS-CoV-2 by Commercially Available Disinfectants and Cleaners
HARADA, Y., Amo, H., Ono, T., MURAI, H., Sasaki, T., Shioda, T., Ikawa, M., & Hirata, Y. (2022) · Biocontrol Science · doi:10.4265/bio.27.223 · Cited by 5
Factors Affecting the Decontamination Process in Hospitals in Saudi Arabia
Felemban, E. M., Youssef, H. A. M., & Thobaity, A. A. (2021) · Risk Management and Healthcare Policy · doi:10.2147/rmhp.s295262 · Cited by 5
Soni, S. K., Marya, T., Sharma, A., Thakur, B., & Soni, R. (2024) · Archives of Microbiology · doi:10.1007/s00203-023-03818-z · Cited by 4
“As the lipid membrane of microorganisms is altered, about 65–90% of the alcohol concentration in a particular hand sanitizer is efficient to destroy or act against microbes (Song et al. 2019).”
Golfiroozi, S., Fashayi, F., Rajabi, A., & Shahryari, A. (2024) · BMC Infectious Diseases · doi:10.1186/s12879-024-09985-8 · Cited by 6
“In another study, Yean et al.‘s reported that accurate implementation of the disinfectant was one of the most important factors in controlling coronavirus [32].”
BackgroundKühnel, C., & Gühne, F. (2024) · Hygiene · doi:10.3390/hygiene4020015 · Cited by 4
Stein, C., Lange, I., Rödel, J., et al. (2021) · Microorganisms · doi:10.3390/microorganisms9061190 · Cited by 4
Voorn, M. G., Tembo, G. M., Rainey, K. E., Teska, P. J., & Oliver, H. F. (2025) · American Journal of Infection Control · doi:10.1016/j.ajic.2025.08.036 · Cited by 5
Food Contact Surfaces, Risk of Contamination, and Solution
Singh, B., Chaudhary, S., Kaur, G., Juneja, V. K., & Sandhu, R. S. (2024) · Springer eBooks · doi:10.1007/978-3-031-51417-3_16 · Cited by 3
Antibacterial and catalytic performance of rGO-CNT-ZrO 2 composite
Sha, M. S., Devarajan, S., Musthafa, F. N., et al. (2023) · International Journal of Environmental & Analytical Chemistry · doi:10.1080/03067319.2023.2230146 · Cited by 3
Improving medical textiles to create a greener operating theatre
Morris, H., & Murray, R. K. (2024) · Journal of the Textile Institute · doi:10.1080/00405000.2024.2321633 · Cited by 5
“Also, according to the reviewers (Song et al., 2019), several information gaps must be filled to obtain consistent and exhaustive knowledge about the interaction between textile and substrate, in particular regarding: i. material compatibility (combination of wipe and disinfectant) ii. liquor ratio…”
Health Impact of Chemical Disinfectant Exposures: A Review
Amaliah, L., Faryanti, D., Asri, A. M. D., et al. (2023) · Jurnal Penelitian Pendidikan IPA · doi:10.29303/jppipa.v9i11.5450 · Cited by 3
“This diluted solution is suitable for various disinfection purposes, including cleaning floors, spills, benchtops, and contaminated clothing (Song et al., 2019; Thomas et al., 2022).”
BackgroundPoint of care ultrasound: a clinical decision support tool for COVID-19
Desai, S. R., Wong, J., Suhitharan, T., Chan, Y. W., & Ng, S.-Y. (2021) · Singapore Medical Journal · doi:10.11622/smedj.2021098 · Cited by 5
“level disinfection with chlorine dioxide, hydrogen peroxide or peroxyacetic acid based wipes for semi-critical or critical applications (contact with non-intact skin, mucous membranes, blood, body fluids, or ultrasound-guided invasive procedures), together with the use of a sterile transducer sheath and sterile gel.((…”
Modern chemical disinfectants and antiseptics. Part I
Britsun, V. M., Simurova, N., Popova, I. V., & Симуров, А. В. (2021) · Journal of organic and pharmaceutical chemistry · doi:10.24959/ophcj.21.231997 · Cited by 3
Analysis of the Antimicrobial Drugs Market in Russia
Khazamova, S. O., Lazareva, N. V., Semenova, L. V., Lukyanov, G. I., Kolosova, O. Y., & Kamalova, O. N. (2023) · Pharmacophore · doi:10.51847/l21qr0rk1s · Cited by 3
Kelley, A. M., Voorn, M. G., Tembo, G. M., Horn, C. M., Li, X., Teska, P. J., & Oliver, H. F. (2023) · Antimicrobial Resistance and Infection Control · doi:10.1186/s13756-023-01266-4 · Cited by 3
“There is a need for further research on the performance of disinfectant towelette products under conditions encountered under realistic use, as reviewed by Boyce, 2021 [13] and Song et al., 2019 [11].”
BackgroundEffects of household cleaning products on the lungs: an update
Silva, E. P. D., Dumas, O., & Moual, N. L. (2025) · Expert Review of Respiratory Medicine · doi:10.1080/17476348.2025.2478968 · Cited by 6
Fermo, P. D., Diban, F., Ancarani, E., Yu, K., D’Arcangelo, S., D’Ercole, S., Lodovico, S. D., Giulio, M. D., & Cellini, L. (2024) · Journal of Applied Microbiology · doi:10.1093/jambio/lxae234 · Cited by 2
Le, H. T. T., Nguyen, H. N., & Vu, N. T. (2025) · Waste and Biomass Valorization · doi:10.1007/s12649-025-02996-9 · Cited by 4
“In terms of application methods and wiping strategies, between two main approaches, without and with mechanical action, the later approach has been reported to have higher surface disinfectant efficacy [ 34].”
Zyoud, S. H., & Zyoud, S. H. (2025) · Journal of Water and Health · doi:10.2166/wh.2025.058 · Cited by 4
Tembo, G. M., Chaggar, G. K., Li, X., Teska, P. J., & Oliver, H. F. (2022) · American Journal of Infection Control · doi:10.1016/j.ajic.2022.07.011 · Cited by 2
Jadidi, A., Irannejad, B., Mohsenifard, M., Hezave, A. K., & Aghaepour, S. M. (2022) · INQUIRY The Journal of Health Care Organization Provision and Financing · doi:10.1177/00469580221093454 · Cited by 2
O uso do ozônio na desinfecção de superfícies: revisão integrativa
Simplício, I. D. O. B., Sousa, S. C., Thomaz, T. S., Lima, F. D. S., Bezerra, J. D. S., Carvalho, M. C. D. O., Ferreira, M. S., & Miranda, M. K. V. (2023) · Acta Paulista de Enfermagem · doi:10.37689/acta-ape/2023ar00542 · Cited by 6
Yan, Y., Huang, S., Zeng, Y., Yue, S., Wang, T., Yuan, L., & Nie, J. (2024) · Skin Pharmacology and Physiology · doi:10.1159/000539100 · Cited by 2
Two-step or one-step – are all methods for neonatal incubator decontamination equal?
Watkin, S., Dunn, H., Ready, D. R., et al. (2024) · Journal of Hospital Infection · doi:10.1016/j.jhin.2024.07.012 · Cited by 1
Rausch, M. D., Barth, G., Dornaika, A., Hornei, B., Ilschner, C., Roesch, K.-M., Gebel, J., Engelhart, S., & Mutters, N. T. (2025) · Journal of Hospital Infection · doi:10.1016/j.jhin.2025.11.024 · Cited by 2
Ação do cloreto de benzalcônio frente ao vírus de influenza e Newcastle
Frozza, R., Bado, C., & Caselles, A. (2020) · PubVet · doi:10.31533/pubvet.v14n2a512.1-4 · Cited by 1
“…viricida) e desta forma os QACs são amplamente utilizados em granjas de aves associado a programas de limpeza e desinfecção e são importantes na prevenção e controle da transmissão de agentes infecciosos dentre e entre os lotes (Ito et al., 2002; Maertens et al., 2019; Song et al., 2019).”
BackgroundModern chemical disinfectants and antiseptics. Part II
Britsun, V. M., Simurova, N., Popova, I. V., & Симуров, А. В. (2021) · Journal of organic and pharmaceutical chemistry · doi:10.24959/ophcj.21.231998 · Cited by 2
Gharib, N., Derakhshandeh, J. F., & Radziszewski, P. (2023) · Elsevier eBooks · doi:10.1016/b978-0-12-821975-1.00003-1 · Cited by 1
Automated Smart Floor Cleaner for Reducing Human Efforts
Ajees, T., Rishok, R., Binish, C., et al. (2023) · Asian Journal of Applied Science and Technology · doi:10.38177/ajast.2023.7215 · Cited by 1
“The machine will be tested on various floor surfaces to ensure its effectiveness and efficiency in cleaning [9].”
BackgroundPublic Practice of using Hand Sanitizer and Disinfectant in Saudi Arabia
Alomi, Y. A., AlHamdan, B. S., Alosaimi, S. O., & Altuwayhir, D. A. (2021) · Pharmacology Toxicology and Biomedical Reports · doi:10.5530/ptb.2021.7.16 · Cited by 1
Synthesis of colloidal nanosilver as active agent of disinfectant using pulse laser ablation
Khumaeni, A., Arifin, Z., & Setiawati, E. (2022) · AIP conference proceedings · doi:10.1063/5.0072890 · Cited by 1
Anesthesia and COVID-19, Peri-Operative Challenges and Recommendations
Andemeskel, Y. M., Mengistu, M. B., Kidanemariam, B. Y., et al. (2020) · Anesthesia & Pain Research · doi:10.33425/2639-846x.1044
Evaluation of Efficacy about Disinfectants in Biological Containment Facilities
Kim, D., Lee, K.-M., Choi, Y., Chun, B.-N., & Jang, W. (2021) · Journal of Bacteriology and Virology · doi:10.4167/jbv.2021.51.1.009
EFFICACY OF DISINFECTION ON VARIOUS SURFACES
Rajiva, R., Sahu, R., Dangwal, V. D., et al. (2021) · INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH · doi:10.36106/ijsr/5402374
Metadata
- Authors
- Song, X., Vossebein, L., & Zille, A.
- Affiliations
- Centro de Ciência e Tecnologia Têxtil (PT)
- Venue
- Antimicrobial Resistance & Infection Control
- Published
- 2019-08-19
- Volume
- 8
- Issue
- 1
- Pages
- 139-139
- ISSN
- 2047-2994 (ISSN-L)
- PMC
- PMC6701098
- OpenAlex
- W2967400753
- Cited by
- 132
- References
- 82
- Citations by year
- 2026: 8 · 2025: 23 · 2024: 15 · 2023: 24 · 2022: 17 · 2021: 29 · 2020: 15 · 2019: 1
- FWCI
- 2.16
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0/ (tdm)
- creativecommons.org/licenses/by/4.0/ (vor)
- Locations
- Antimicrobial Resistance and Infection Control (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) (submittedVersion, other-oa)
- Funders
- Fundação para a Ciência e a Tecnologia (SFRH/BD/130028/2017, IF/00071/2015, UID/CTM/00264/2019)
- Topics
- Health Sciences › Medicine › Infectious Diseases › Infection Control in Healthcare
- Life Sciences › Immunology and Microbiology › Microbiology › Medical Device Sterilization and Disinfection
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Keywords
- surface disinfection, hospital infection control, disinfectant efficacy, medical device decontamination
- MeSH terms
- Cross Infection, Disinfectants, Disinfection, Environmental Microbiology, Equipment Contamination, Humans
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.