Abstract

Background: Eustachian tube (ET) dysfunction can be very difficult to diagnose accurately. Our aim is to determine whether a newly developed sonotubometric test using clicks can reliably detect ET opening during swallowing in normal ET subjects, and patulous ET (PET) in subjects with ET dysfunction. Methods: Sixteen subjects (19 normal ET ears and 6 PET ears) were individually placed in a sound-isolated audiometry booth and subjected to a 1000Hz click train stimulus, played through the nose. PET subjects were identified through the ET clinic at our institution, while healthy subjects were recruited. Transmission through the ET was recorded by a microphone in the ear ipsilateral to the presenting nostril, during no swallow and swallow states, and this was used to compute a power ratio (power in the frequency range of interest to the whole frequency range). The power transmission ratio both before and after the swallow was averaged, and represented the baseline (BaseR). The power transmission ratio during swallow represented the peak (PeakR). The same process was repeated in the absence of a stimulus to account for swallowing noise. Wilcoxon rank rum tests were performed to determine statistical significance. Results: It was found that for healthy ET patients, the median difference between the PeakR and BaseR was 0.51 ( p = 0.004). For the PET patients in this study, the median difference between the PeakR and the BaseR was 3.30 ( p = 0.041). Comparing the baseline between groups revealed that PET patients had a median BaseR 1.05 higher than healthy ET patients. PET patients had a median PeakR of 3.84 higher than healthy ET patients. Both were deemed to be statistically significant ( p = 0.003, p = 0.003 respectively). A significant difference was found between median PeakR for the stimulus and no-stimulus condition for the healthy ET group (0.59, p < 0.001) and for the PET group (4.39, p = 0.031), indicating that it was unlikely that swallowing noise caused false positive results. Conclusion: The results of this study suggest that a novel click stimulus is capable of detecting ET opening during swallowing in healthy patients as well as highlighting PET in diseased subjects.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s40463-017-0227-x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 12

  1. 10.1016/j.otc.2006.08.011 · DOI · Paper page
  2. Spear SA Arriaga MA. Recent Advances in Otolaryngology Head and Neck Surgery Vol. 2 Anil K Lalwani Markus HF Pfister. New Delhi India: Jaypee Brothers Medical Publishers (P) Ltd 2013. Otol Neurotol. 2013;34. p. 105–106 · doi:10.1097/mao.0000000000000237
  3. Bluestone CD, Cantekin EI Panel on experiences with testing Eustachian tube function: current clinical methods, indications and interpretation of Eustachian tube function tests Ann Otol 1981 90 552 62 1:STN:280:DyaL38%2FovFOntg%3D%3D
  4. 10.3766/jaaa.22.4.2 · DOI · Paper page
  5. 10.1097/AUD.0b013e31829db80f · doi:10.1097/aud.0b013e31829db80f
  6. 10.3766/jaaa.25.5.1 · doi:10.3766/jaaa.25.5.1
  7. 10.3109/00016487809107519 · DOI
  8. 10.3109/00016487809124724 · DOI · Paper page
  9. 10.3109/00016489.2010.492481 · DOI
  10. 10.21053/ceo.2015.00626 · doi:10.21053/ceo.2015.00626
  11. 10.1007/s00405-009-1074-9 · DOI
  12. 10.1097/MAO.0000000000001130 · DOI · Paper page

Cited by

See all 6

Metadata

Authors
Pyne, J. M., Amoako-Tuffour, Y., Earle, G., McIntyre, G., Butler, M. B., & Bance, M.
Affiliations
  • Faculty of Medicine, Dalhousie University, Halifax, NS, Canada
  • Department of Surgery, Division of Otolaryngology – Head and Neck Surgery, Faculty of Medicine, Dalhousie University, Halifax, NS, Canada
Venue
Journal of Otolaryngology - Head & Neck Surgery
Published
2017-01
Volume
46
Issue
1
ISSN
1916-0216
Cited by
6
References
0
Language
en
Licence
Funders
Springboard Atlantic

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transmission of a novel sonotubometry acoustic click stimulus in healthy and patulous eustachian tube subjects: A retrospective case -control study. https://app.cochat.ai/papers/10.1186/s40463-017-0227-x
The paper
Pyne, J. M., Amoako-Tuffour, Y., Earle, G., McIntyre, G., Butler, M. B., & Bance, M. (2017). Transmission of a novel sonotubometry acoustic click stimulus in healthy and patulous eustachian tube subjects: A retrospective case -control study. Journal of Otolaryngology - Head & Neck Surgery. https://doi.org/10.1186/s40463-017-0227-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.