The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Cytocam-IDF (incident dark field illumination) imaging for bedside monitoring of the microcirculation
Open accessAbstract
Background: Orthogonal polarized spectral (OPS) and sidestream dark field (SDF) imaging video microscope devices were introduced for observation of the microcirculation but, due to technical limitations, have remained as research tools. Recently, a novel handheld microscope based on incident dark field illumination (IDF) has been introduced for clinical use. The Cytocam-IDF imaging device consists of a pen-like probe incorporating IDF illumination with a set of high-resolution lenses projecting images on to a computer controlled image sensor synchronized with very short pulsed illumination light. This study was performed to validate Cytocam-IDF imaging by comparison to SDF imaging in volunteers. Methods: This study is a prospective, observational study. The subjects consist of 25 volunteers. Results: Sublingual microcirculation was evaluated using both techniques. The main result was that Cytocam-IDF imaging provided better quality images and was able to detect 30% more capillaries than SDF imaging (total vessels density Cytocam-IDF: 21.60 ± 4.30 mm/mm 2 vs SDF: 16.35 ± 2.78 mm/mm 2, p < 0.0001). Comparison of the images showed increased contrast, sharpness, and image quality of both venules and capillaries. Conclusions: Cytocam-IDF imaging detected more capillaries and provided better image quality than SDF imaging. It is concluded that Cytocam-IDF imaging may provide a new improved imaging modality for clinical assessment of microcirculatory alterations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microvascular alterations in patients with acute severe heart failure and cardiogenic shock
De Backer, D., Creteur, J., Dubois, M.-J., Sakr, Y., & Vincent, J.-L. (2004) · American Heart Journal · doi:10.1016/j.ahj.2003.07.006 · Cited by 472
Cited by
Ince, C., Mayeux, P. R., Nguyen, T., Gomez, H., Kellum, J. A., Ospina-Tascón, G. A., Hernandez, G., Murray, P., & De Backer, D. (2016) · Shock · doi:10.1097/shk.0000000000000473 · Cited by 647
Self-citationHemodynamic coherence and the rationale for monitoring the microcirculation
Ince, C. (2015) · Critical Care · doi:10.1186/cc14726 · Cited by 611
Self-citationESICM, O. B. O. T. C. D. S. O. T., Ince, C., Boerma, E. C., Cecconi, M., De Backer, D., Shapiro, N. I., Duranteau, J., Pinsky, M. R., Artigas, A., Teboul, J.-L., et al. (2018) · Intensive Care Medicine · doi:10.1007/s00134-018-5070-7 · Cited by 480
Self-citationMicrocirculation: Physiology, Pathophysiology, and Clinical Application
Guven, G., Hilty, M. P., & Ince, C. (2020) · Blood Purification · doi:10.1159/000503775 · Cited by 264
Self-citationHemodynamic monitoring in the era of digital health
Michard, F. (2016) · Annals of Intensive Care · doi:10.1186/s13613-016-0119-7 · Cited by 57
Metadata
- Authors
- Aykut, G., Veenstra, G., Scorcella, C., Ince, C., & Boerma, C.
- Venue
- Intensive Care Medicine Experimental
- Published
- 2015-01-31
- Volume
- 3
- Issue
- 1
- Pages
- 40-40
- ISSN
- 2197-425X (ISSN-L)
- OpenAlex
- W2010774143
- Cited by
- 244
- References
- 1
- FWCI
- 19.21
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cytocam-IDF (incident dark field illumination) imaging for bedside monitoring of the microcirculation. https://app.cochat.ai/papers/10.1186/s40635-015-0040-7
- The paper
- Aykut, G., Veenstra, G., Scorcella, C., Ince, C., & Boerma, C. (2015). Cytocam-IDF (incident dark field illumination) imaging for bedside monitoring of the microcirculation. Intensive Care Medicine Experimental. https://doi.org/10.1186/s40635-015-0040-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.