CoChat

Mechanical power at a glance: a simple surrogate for volume-controlled ventilation

Open access
Giosa, Lorenzo, Busana, Mattia, Pasticci, Iacopo, Bonifazi, Matteo, Macrì, Matteo Maria, Romitti, Federica, Vassalli, Francesco, Chiumello, Davide, Quintel, Michael, Marini, J. J., Gattinoni, Luciano · 2019 · Intensive Care Medicine Experimental
Cited by 166

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Background: Mechanical power is a summary variable including all the components which can possibly cause VILI (pressures, volume, flow, respiratory rate). Since the complexity of its mathematical computation is one of the major factors that delay its clinical use, we propose here a simple and easy to remember equation to estimate mechanical power under volume-controlled ventilation:$$ \mathrm{Mechanical}\ \mathrm{Power}=\frac{\mathrm{VE}\times \left(\mathrm{Peak}\ \mathrm{Pressure}+\mathrm{PEEP}+F/6\right)}{20} $$Mechanical Power=VE×Peak Pressure+PEEP+F/620 where the mechanical power is expressed in Joules/minute, the minute ventilation (VE) in liters/minute, the inspiratory flow (F) in liters/minute, and peak pressure and positive end-expiratory pressure (PEEP) in centimeter of water. All the components of this equation are continuously displayed by any ventilator under volume-controlled ventilation without the need for clinician intervention. To test the accuracy of this new equation, we compared it with the reference formula of mechanical power that we proposed for volume-controlled ventilation in the past. The comparisons were made in a cohort of mechanically ventilated pigs (485 observations) and in a cohort of ICU patients (265 observations). Results: Both in pigs and in ICU patients, the correlation between our equation and the reference one was close to the identity. Indeed, the R2 ranged from 0.97 to 0.99 and the Bland-Altman showed small biases (ranging from + 0.35 to − 0.53 J/min) and proportional errors (ranging from + 0.02 to − 0.05). Conclusions: Our new equation of mechanical power for volume-controlled ventilation represents a simple and accurate alternative to the more complex ones available to date. This equation does not need any clinical intervention on the ventilator (such as an inspiratory hold) and could be easily implemented in the software of any ventilator in volume-controlled mode. This would allow the clinician to have an estimation of mechanical power at a simple glance and thus increase the clinical consciousness of this variable which is still far from being used at the bedside. Our equation carries the same limitations of all other formulas of mechanical power, the most important of which, as far as it concerns VILI prevention, are the lack of normalization and its application to the whole respiratory system (including the chest wall) and not only to the lung parenchyma.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s40635-019-0276-8

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Metadata

Authors
Giosa, L., Busana, M., Pasticci, I., Bonifazi, M., Macrì, M. M., Romitti, F., Vassalli, F., Chiumello, D., Quintel, M., Marini, J. J., & Gattinoni, L.
Venue
Intensive Care Medicine Experimental
Published
2019-11-27
Volume
7
Issue
1
Pages
61-61
ISSN
2197-425X (ISSN-L)
OpenAlex
W2990866683
Cited by
166
References
5
FWCI
8.73
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mechanical power at a glance: a simple surrogate for volume-controlled ventilation. https://app.cochat.ai/papers/10.1186/s40635-019-0276-8
The paper
Giosa, L., Busana, M., Pasticci, I., Bonifazi, M., Macrì, M. M., Romitti, F., Vassalli, F., Chiumello, D., Quintel, M., Marini, J. J., & Gattinoni, L. (2019). Mechanical power at a glance: a simple surrogate for volume-controlled ventilation. Intensive Care Medicine Experimental. https://doi.org/10.1186/s40635-019-0276-8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.