Cited by 19Patient Safety and Medication ErrorsNursing education and managementDiabetes Management and Research

Determinants of nurse satisfaction using insulin pen devices with safety needles: an exploratory factor analysis

Open access
Veronesi, Giovanni, Poerio, Carmine S., Braus, Alessandra, Destro, Maurizio, Gilberti, Lavinia, Meroni, Giovanni, Davis, Estella M., Bossi, Antonio C.·2015·Clinical Diabetes and Endocrinology

Abstract

BACKGROUND: A paucity of data exists to examine nurses' satisfaction with the use of insulin pens with safety needles in hospitalized patients with diabetes. We investigated major determinants of nurses' preference of the method of insulin administration in the context of a General Hospital in Northern Italy. METHODS: Consecutive patients admitted to three hospital units of different care intensity requiring insulin received insulin therapy through either the vial/syringe method (October to December 2012) or pen/safety needles with dual-ended protection method (January to March 2013). Before the implementation of insulin pens, floor nurses received a specific training program for proper insulin pen injection technique including individual testing of the devices (pen/safety needles). At the end of the study, nurses completed the Nursing Satisfaction Survey Questionnaire. Cronbach's alpha was used to determine the internal consistency and reliability of the questionnaire. Major determinants of satisfaction were investigated through an exploratory factor analysis. The association between each retained factor and time spent to teach patients how to self-inject insulin with pen devices was also investigated. RESULTS: Fifty-three out of 60 nurses (mean age ± SD 36.2 ± 8.5 years, 85 % women, 57 % with 10+ years of working experience) returned the questionnaire. Internal consistency of the questionnaire was satisfactory (Cronbach's alpha > 0.9). Three months after their introduction, about 92 % of nurses considered pen devices an "improvement" over the vial/syringe method. Two factors explained 85 % of nurses' satisfaction, one related to convenience and ease of use, and the other to satisfaction/time spent for dose preparation and administration. The latter factor was inversely correlated with time spent on patients' training tasks. CONCLUSIONS: Nurses' satisfaction with pen devices was higher than previously reported, possibly reinforced by safety needles with dual-ended protection. Perceived workload was a major determinant of nurse satisfaction using pen devices with safety needles. To facilitate the introduction of insulin pens in the hospital setting, it should be specifically addressed during training programs in the switch-over period.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s40842-015-0015-3

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Several reports indicate that inpatient use of insulin pens is safe and may improve nurse satisfaction when safety protocols, including nursing education and bar code scanning procedures, are in place to guarantee single-person use.

    “Several reports indicate that inpatient use of insulin pens is safe and may improve nurse satisfaction when safety protocols, including nursing education and bar code scanning procedures, are in place to guarantee single-person use (70-73).”

    From 16. Diabetes Care in the Hospital: Standards of Care in Diabetes—2026 (2026) · cites this paper as [70]

    The Discussion reports that about 92% of nurses considered pens with safety needles an improvement, and that no needlestick injuries occurred during the three-month pen-use period. The Methods describe nurse training, but the paper does not report bar-code scanning or a procedure guaranteeing single-person use; its Background also describes inpatient adoption as controversial because of contamination risks. (LLM, conf=0.88)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

No references could be resolved yet.

Research works printed but not linked: 15

  1. [2]Molife C Lee LJ Shi L Sawhney M Lenox SM Assessment of patient-reported outcomes of insulin pen devices versus conventional vial and syringe Diabetes Technol Ther 2009 11 8 529 38 10.1089/dia.2009.0007 19698067 · DOI
  2. [3]Perfetti R Reusable and disposable insulin pens for the treatment of diabetes: understanding the global differences in user preference and an evaluation of inpatient insulin pen use Diabetes Technol Ther 2010 12 Suppl 1 S79 85 20515312
  3. [4]Cornell S Managing diabetes-related costs and quality of life issues: Value of insulin analogs and pens for inpatient use Health Policy 2010 96 3 191 9 10.1016/j.healthpol.2010.02.006 20226560 · DOI
  4. [5]Davis EM Christensen CM Nystrom KK Foral PA Destache C Patient satisfaction and costs associated with insulin administered by pen device or syringe during hospitalization Am J Health Syst Pharm 2008 65 14 1347 57 10.2146/ajhp070636 18593681 · DOI
  5. [6]Ward LG Aton SS Impact of an interchange program to support use of insulin pens Am J Health Syst Pharm 2011 68 14 1349 52 10.2146/ajhp100535 21719595 · DOI
  6. [7]Herdman ML Larck C Schliesser SH Jelic TM Biological contamination of insulin pens in a hospital setting Am J Health Syst Pharm 2013 70 14 1244 8 10.2146/ajhp120728 23820462 · DOI
  7. [8]Davis EM Bebee A Crawford LA Destache C Nurse satisfaction using insulin pens in hospitalized patients Diabetes Educ 2009 35 5 799 809 10.1177/0145721709340057 19633151 · DOI
  8. [10]Cappelleri JC, Gerber RA, Kourides IA, Gelfand RA. Development and factor analysis of a questionnaire to measure patient satisfaction with injected and inhaled insulin for type I diabetes. Diabetes Care. 2000;23:1799–803. 11128356
  9. [11]Szeinbach SL, Barnes JH, Summers KH, Lenox SM. Development of an instrument to assess expectations of and preference for an insulin injection pen compared with the vial and syringe. Clin Ther. 2004;26:590–7. 15189756
  10. [13]Cronbach LJ Coefficient alpha and the internal structure of tests Psychometrika 1951 16 297 334 10.1007/BF02310555 · DOI · Paper page
  11. [14]Siegel S Castellan NJ Non parametric statistics for the behavioral sciences 1992 2 New York McGraw-Hill
  12. [15]Davis EM Foral PA Dull RB Smith AN Review of insulin therapy and pen use in hospitalized patients Hosp Pharm 2013 48 396 405 10.1310/hpj4805-396 24421496 PMC3839460 · DOI
  13. [16]Pellissier G Migueres B Tarantola A Abiteboul D Lolom I Bouvet E Risk of needlestick inkuries by injection pens J Hosp Infect 2006 63 1 60 4 10.1016/j.jhin.2005.12.006 16540200 · DOI
  14. [17]Lee JM Botteman MF Nicklasson L Cobden D Pashos CL Needlestick injury in acute care nurses caring for patients with diabetes mellitus: a retrospective study Curr Med Res Opin 2005 21 741 7 10.1185/030079905X46205 15969873 · DOI
  15. [18]Schaefer MK Kossover RA Perz JF Sharing insulin pens: are you putting patients at risk? Diabetes Care 2013 36 11 e188 9 10.2337/dc13-1522 24159184 PMC3816894 · DOI

Cited by

Sorted by citations

Authors
Veronesi, G., Poerio, C. S., Braus, A., Destro, M., Gilberti, L., Meroni, G., Davis, E. M., & Bossi, A. C.
Affiliations
  • University of Insubria (IT)
  • Azienda Ospedaliera Treviglio (IT)
  • Creighton University (US)
Corresponding author
Bossi, Antonio C.
Venue
Clinical Diabetes and Endocrinology
Published
2015-11-09
Volume
1
Issue
1
Pages
15-15
ISSN
2055-8260 (ISSN-L)
OpenAlex
W2162815165
Cited by
19
References
0
Citations by year
2025: 1 · 2024: 2 · 2023: 2 · 2022: 2 · 2021: 3 · 2020: 2 · 2019: 1 · 2018: 4 · 2017: 1 · 2015: 1
FWCI
3.45
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • Clinical Diabetes and Endocrinology (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • IrInSubria (University of Insubria) (submittedVersion)
Topics
  • Health Sciences › Health Professions › Emergency Medical Services › Patient Safety and Medication Errors
  • Health Sciences › Nursing › Research and Theory › Nursing education and management
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
Keywords
insulin pens, safety needles, nursing satisfaction, insulin administration, hospitalized diabetes patients, perceived workload, nurse training, self-injection training

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review