Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Release of silicone oil droplets from syringes

Open access
Melo, Gustavo Barreto, Dias Junior, Celso de Souza, Carvalho, Mariana Reis, Cardoso, Alexandre Lima, Morais, Fábio Barreto, Figueira, Ana Carolina Migliorini, Lima Filho, Acácio Alves Souza, Emerson, Geoffrey Guy, Maia, Maurício · 2019 · International Journal of Retina and Vitreous

Abstract

Intravitreal silicone oil droplets have been found in the vitreous. The aim of this study is to compare the rates of silicone oil released by different brands of commonly used syringes for intravitreal injection after agitation by flicking. Three models of two brands of syringes were analyzed for their rates of silicone oil release: Saldanha Rodrigues (SR) 1 mL insulin syringe (SR, Brazil, syringe 1), Becton–Dickinson (BD) Plastipak 1 mL insulin syringe (Brazil, syringe 2), and BD Safety-Glide 1 mL insulin syringe (USA, syringe 3). All syringes were tested under four different conditions: positive control (fluid with addition of silicone oil) without agitation (group 1, n = 5); positive control with agitation (group 2, n = 3); fluid only without agitation (group 3, n = 5); and fluid only with agitation (group 4, n = 5). Masked graders performed all analyses using light microscopy. All syringes (1, 2, and 3) released silicone oil droplets in the positive control group regardless of the agitation status (groups 1 and 2). When no oil was added and the syringes were not agitated, only syringe 1 released silicone oil droplets (40% of samples). After agitation, syringes 1 and 3 released silicone oil droplets in all samples. Quantitative analysis showed a significantly ( P = 0.011; 11.2 ± 2.9 vs. 0.6 ± 0.9, respectively) higher mean number of silicone oil droplets released by syringe 1 after agitation compared to no agitation. Syringe 1 also had significantly ( P = 0.002, 11.2 ± 2.9 vs. 0.0 ± 0.0 vs. 2.2 ± 0.8, respectively) more droplets than syringes 2 and 3 after agitation. Syringes commonly used for intravitreal injections frequently release silicone oil droplets when agitated by flicking, especially the SR insulin ones. We recommend that they not be agitated at the time of intravitreal injection and that the manufacturers consider producing syringes adapted for intraocular use.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s40942-018-0153-8

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Silicone oil droplets (arrowhead) and air bubbles (arrow) in an agitated positive control (group 2) of syringe 3 (Becton–Dickinson)
Fig. 1 Silicone oil droplets (arrowhead) and air bubbles (arrow) in an agitated positive control (group 2) of syringe 3 (Becton–Dickinson)CC BY · PubMed Central
Fig. 2 Images from syringes 1 [Saldanha Rodrigues (SR) 1-mL insulin syringe, a–d], 2 [Becton–Dickinson (BD) Plastipak 1-mL insulin syringe, e–h], and 3 [BD Safetyglide insulin syringe, i–l]. In syringe 1, oil droplets are seen in all groups: a Isolated silicone oil droplet in a positive control without agitation (group 1). b Multiple silicone oil droplets in a positive control with agitation (group 2). c Isolated silicone oil droplet in fluid-only without agitation (group 3). d Multiple silicone oil droplets in fluid-only with agitation (group 4). In syringe 2, no oil is seen in groups 3 and 4: e Positive control without agitation (group 1). f A positive control with agitation (group 2). g Fluid-only without agitation (group 3). h Fluid-only with agitation (group 4). In syringe 3, silicone oil is seen in three groups. i Isolated silicone oil droplet in a positive control without agitation (group 1). j Multiple silicone oil droplets in a positive control with agitation (group 2). k No silicone oil droplet in fluid-only without agitation (group 3). l Four silicone oil droplets in fluid-only with agitation (group 4)
Fig. 2 Images from syringes 1 [Saldanha Rodrigues (SR) 1-mL insulin syringe, a–d], 2 [Becton–Dickinson (BD) Plastipak 1-mL insulin syringe, e–h], and 3 [BD Safetyglide insulin syringe, i–l]. In syringe 1, oil droplets are seen in all groups: a Isolated silicone oil droplet in a positive control without agitation (group 1). b Multiple silicone oil droplets in a positive control with agitation (group 2). c Isolated silicone oil droplet in fluid-only without agitation (group 3). d Multiple silicone oil droplets in fluid-only with agitation (group 4). In syringe 2, no oil is seen in groups 3 and 4: e Positive control without agitation (group 1). f A positive control with agitation (group 2). g Fluid-only without agitation (group 3). h Fluid-only with agitation (group 4). In syringe 3, silicone oil is seen in three groups. i Isolated silicone oil droplet in a positive control without agitation (group 1). j Multiple silicone oil droplets in a positive control with agitation (group 2). k No silicone oil droplet in fluid-only without agitation (group 3). l Four silicone oil droplets in fluid-only with agitation (group 4)CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

See all 50

Metadata

Authors
Melo, G. B., Dias Junior, C. D. S., Carvalho, M. R., Cardoso, A. L., Morais, F. B., Figueira, A. C. M., Lima Filho, A. A. S., Emerson, G. G., & Maia, M.
Affiliations
  • Universidade Federal de São Paulo (BR)
  • Brazilian Center for Research in Energy and Materials (BR)
  • The Retina Center (US)
Corresponding author
Melo, Gustavo Barreto
Venue
International Journal of Retina and Vitreous
Published
2019-01-03
Volume
5
Issue
1
Pages
1-1
ISSN
2056-9920 (ISSN-L)
OpenAlex
W2922373462
Cited by
50
References
22
Citations by year
2026: 5 · 2025: 11 · 2024: 6 · 2023: 4 · 2022: 4 · 2021: 8 · 2020: 8 · 2019: 4
FWCI
3.97
Type
journal article
Language
en
Open access
Licence
  • cc-by
  • creativecommons.org/licenses/by/4.0/ (tdm)
Locations
  • International Journal of Retina and Vitreous (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, other-oa)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Funders
Regeneron Pharmaceuticals
Topics
  • Health Sciences › Medicine › Ophthalmology › Retinal and Macular Surgery
  • Physical Sciences › Engineering › Biomedical Engineering › Intravenous Infusion Technology and Safety
  • Health Sciences › Medicine › Ophthalmology › Retinal Diseases and Treatments
Keywords
silicone oil droplets, intravitreal injection, insulin syringes, silicone oil emulsification, syringe design, vitrectomy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Release of silicone oil droplets from syringes. https://app.cochat.ai/papers/10.1186/s40942-018-0153-8
The paper
Melo, G. B., Dias Junior, C. D. S., Carvalho, M. R., Cardoso, A. L., Morais, F. B., Figueira, A. C. M., Lima Filho, A. A. S., Emerson, G. G., & Maia, M. (2019). Release of silicone oil droplets from syringes. International Journal of Retina and Vitreous. https://doi.org/10.1186/s40942-018-0153-8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.