A review of various modalities in breast imaging: technical aspects and clinical outcomes
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Background: Nowadays, breast cancer is the second cause of death after cardiovascular diseases. In general, about one out of eight women (about 12%) suffer from this disease during their life in the USA and European countries. If breast cancer is detected at an early stage, its survival rate will be very high. Several methods have been introduced to diagnose breast cancer with their clinical advantages and disadvantages. Main text: In this review, various methods of breast imaging have been introduced. Furthermore, the sensitivity and specificity of each of these methods have been investigated. For each of the imaging methods, articles that were relevant to the past 10 years were selected through electronic search engines, and then the most relevant papers were selected. Finally, about 40 articles were studied and their results were categorized and presented in the form of a report as follows. Various breast cancer imaging techniques were extracted as follows: mammography, contrast-enhanced mammography, digital tomosynthesis, sonography, sonoelastography, magnetic resonance imaging, magnetic elastography, diffusion-weighted imaging, magnetic spectroscopy, nuclear medicine, optical imaging, and microwave imaging. Conclusion: The choice of these methods depends on the patient’s state and stage, the age of the individual and the density of the breast tissue. Hybrid imaging techniques appear to be an acceptable way to improve detection of breast cancer. This review article can be useful in choosing the right method for imaging in people suspected of breast cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bray, F., Ferlay, J., Soerjomataram, I., Siegel, R. L., Torre, L. A., & Jemal, A. (2018) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21492 · Cited by 84,109 · cited 1×
“Breast cancer is the most common type of malignancy in women, and one of the three most common cancers worldwide, along with lung and colon cancer [1, 2].”
BackgroundJemal, A., Bray, F., Center, M. M., Ferlay, J., Ward, E., & Forman, D. (2011) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.20107 · Cited by 54,679
Harbeck, N., & Gnant, M. (2017) · The Lancet · doi:10.1016/s0140-6736(16)31891-8 · Cited by 2,280
Incidence and Mortality and Epidemiology of Breast Cancer in the World
Ghoncheh, M., Pournamdar, Z., & Salehiniya, H. (2016) · Asian Pacific Journal of Cancer Prevention · doi:10.7314/apjcp.2016.17.s3.43 · Cited by 1,115 · cited 2×
“The overall prevalence rate and mortality rate has increased in developing countries [3].”
BackgroundUltrasound elastography: Principles and techniques
Gennisson, J.-L., Deffieux, T., Fink, M., & Tanter, M. (2013) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2013.01.022 · Cited by 1,052 · cited 1×
“through the medium [31] Iranmakani et al.”
Health Risks from Exposure to Low Levels of Ionizing Radiation: BEIR VII Phase 2
(2006) · National Academies Press eBooks · doi:10.17226/11340 · Cited by 904
Microwave Imaging for Breast Cancer
Nikolova, N. (2011) · IEEE Microwave Magazine · doi:10.1109/mmm.2011.942702 · Cited by 640 · cited 2×
“specificity of mammography ranges from 82 to 97% [8].”
BackgroundUltrasound Imaging Technologies for Breast Cancer Detection and Management: A Review
Guo, R., Lu, G., Qin, B., & Fei, B. (2018) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2017.09.012 · Cited by 542 · cited 2×
“The matrix array creates a beam in both positions and forms a pyramidal volume [25].”
BackgroundMRI for breast cancer screening, diagnosis, and treatment
Morrow, M., Waters, J., & Morris, E. (2011) · The Lancet · doi:10.1016/s0140-6736(11)61350-0 · Cited by 448 · cited 2×
“However, in high-risk cases, this method is recommended [10].”
BackgroundMethodDiffusion-weighted breast MRI: Clinical applications and emerging techniques
Partridge, S. C., Nissan, N., Rahbar, H., Kitsch, A. E., & Sigmund, E. E. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25479 · Cited by 340 · cited 1×
“ation times produce higher signal intensities in DW images [14, 15, 35] Fig.”
Background
Cited by
Current State of Breast Cancer Diagnosis, Treatment, and Theranostics
Bhushan, A., Gonsalves, A., & Menon, J. U. (2021) · Pharmaceutics · doi:10.3390/pharmaceutics13050723 · Cited by 298
Metadata
- Authors
- Iranmakani, S., Mortezazadeh, T., Sajadian, F., Ghaziani, M. F., Ghafari, A., Khezerloo, D., & Musa, A. E.
- Venue
- Egyptian Journal of Radiology and Nuclear Medicine
- Published
- 2020-04-16
- Volume
- 51
- Issue
- 1
- ISSN
- 0378-603X (ISSN-L)
- 2090-4762
- OpenAlex
- W3031941587
- Cited by
- 219
- References
- 29
- FWCI
- 10.96
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A review of various modalities in breast imaging: technical aspects and clinical outcomes. https://app.cochat.ai/papers/10.1186/s43055-020-00175-5
- The paper
- Iranmakani, S., Mortezazadeh, T., Sajadian, F., Ghaziani, M. F., Ghafari, A., Khezerloo, D., & Musa, A. E. (2020). A review of various modalities in breast imaging: technical aspects and clinical outcomes. Egyptian Journal of Radiology and Nuclear Medicine. https://doi.org/10.1186/s43055-020-00175-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.