Frequency selective fingerprint sensor: the Terahertz unity platform for broadband chiral enantiomers multiplexed signals and narrowband molecular AIT enhancement
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Chiral enantiomers have different pharmacological and pharmacokinetic characteristics. It is important to strictly detect chiral component for avoiding being harmful to the human body due to side effects. Terahertz (THz) trace fingerprint detection is essential because the molecular vibrations of various biological substances such as chiral enantiomers are located in THz range. Recent reported enhanced trace fingerprint technologies have some drawbacks. For instance, multiplexing technology suffered from narrow operation range and limitation by frequency resolution of commercial THz time domain spectroscopy; Absorption induced transparency (AIT) identification for narrowband molecular oscillations suffered from random resonance frequency drift due to fabrication error. In this paper, we proposed frequency-selective fingerprint sensor (FSFS), which can experimentally achieve enhanced trace fingerprint detection by both broadband multiplexing technology and robust AIT identification. Such FSFS is based on polarization independent reconfiguration metasurfaces array. Broadband absorption lines of trace-amount chiral carnitine were boosted with absorption enhancement factors of about 7.3 times based on frequency-selective multiplexing at 0.95–2.0 THz. Enhanced trace narrowband α-lactose fingerprint sensing can be observed at several array structures with absorption enhancement factors of about 7 times based on AIT, exhibiting good robustness. The flexibility and versatility of proposed FSFS has potential applications for boosting trace chiral enantiomer detection as well as diversity of molecular fingerprints identification by both multiplexing and AIT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging-based molecular barcoding with pixelated dielectric metasurfaces
Tittl, A., Leitis, A., Liu, M., Yesilkoy, F., Choi, D.-Y., Neshev, D. N., Kivshar, Y. S., & Altug, H. (2018) · Science · doi:10.1126/science.aas9768 · Cited by 1,329 · cited 2×
“Up to now, there are two mechanisms that can achieve THz trace molecular fingerprint sensing: absorption induced transparency (AIT) [25, 26] and multiplexing technology [27–30].”
BackgroundPulsed terahertz spectroscopy of DNA, bovine serum albumin and collagen between 0.1 and 2.0 THz
Markelz, A. G., Roitberg, A., & Heilweil, E. J. (2000) · Chemical Physics Letters · doi:10.1016/s0009-2614(00)00227-x · Cited by 705
( R )-2-Hydroxyglutarate Is Sufficient to Promote Leukemogenesis and Its Effects Are Reversible
Losman, J.-A., Looper, R. E., Koivunen, P., Lee, S., Schneider, R. K., McMahon, C., Cowley, G. S., Root, D. E., Ebert, B. L., & Kaelin, W. G. (2013) · Science · doi:10.1126/science.1231677 · Cited by 703 · cited 1×
“Terahertz (THz) wave is located in the frequency range of 0.1–10 THz electromagnetic spectrum, which has the advantages of noninvasive and nonionizing properties [8].”
BackgroundInfluentialAngle-multiplexed all-dielectric metasurfaces for broadband molecular fingerprint retrieval
Leitis, A., Tittl, A., Liu, M., Lee, B. H., Gu, M. B., Kivshar, Y. S., & Altug, H. (2019) · Science Advances · doi:10.1126/sciadv.aaw2871 · Cited by 542 · cited 1×
“Despite the widely used all-dielectric metasurfaces in mid-infrared fingerprint metasensing [27, 28], the THz all-dielectric metasurfaces may suffer from nonnegligible surface undulation which requires complicated and dedicated conformal coating interface engineering.”
Lien Nguyen, K., Friščić, T., Day, G. M., Gladden, L. F., & Jones, W. (2007) · Nature Materials · doi:10.1038/nmat1848 · Cited by 289 · cited 1×
“THz spectroscopy has attracted wide attention due to its non-contact, label-free, broadband detection, and energy matching with intermolecular interactions, such as translational and rotational energy of a molecule [9–11].”
BackgroundTan, T. C., Srivastava, Y. K., Ako, R. T., Wang, W., Bhaskaran, M. C., Sriram, S., Al-Naib, I. A. I., Plum, E., & Singh, R. (2021) · Advanced Materials · doi:10.1002/adma.202100836 · Cited by 276 · cited 1×
“In addition, bound state in the continuum mode was also excited and illustrated to achieve metamaterial sensing with high sensitivity by coating Ge film [18].”
BackgroundLiu, K., Brown, M. G., & Saykally, R. J. (1997) · The Journal of Physical Chemistry A · doi:10.1021/jp9707807 · Cited by 214
Terahertz Microfluidic Sensing with Dual‐Torus Toroidal Metasurfaces
Xu, J., Liao, D., Gupta, M., Zhu, Y., Zhuang, S., Singh, R., & Chen, L. (2021) · Advanced Optical Materials · doi:10.1002/adom.202100024 · Cited by 172 · cited 1×
“For instance, the toroidal resonance are used to realize refractive index (RI) sensing of highly absorptive analytes [15].”
BackgroundSelf-citationZhang, Z., Zhong, C., Fan, F., Liu, G., & Chang, S. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.129315 · Cited by 148 · cited 1×
“To overcome this difficulty, Chang et al. [13] used vibrational circular dichroism of chiral metasurface to identify optically active substances with different molar absorptivity, which were used for the qualitative analysis of chiral enantiomers.”
MethodDefect‐Induced Fano Resonances in Corrugated Plasmonic Metamaterials
Chen, L., Xu, N., Singh, L., Cui, T. J., Singh, R., Zhu, Y., & Zhang, W. (2017) · Advanced Optical Materials · doi:10.1002/adom.201600960 · Cited by 148 · cited 1×
“The permittivity of the fused quartz substrate was 3.84 with a loss tangent tan δ = 0.001, and the electrical conductivity of gold is 4.561 × 10 7 S/m [33, 34].”
BackgroundInfluentialSelf-citation
Cited by
Zhang, Z., Wang, Z., Zhang, C., Yao, Z., Zhang, S., Wang, R., Tian, Z., Han, J., Chang, C., Lou, J., et al. (2024) · Advanced Materials · doi:10.1002/adma.202308453 · Cited by 309
Lyu, J., Huang, L., Chen, L., Zhu, Y., & Zhuang, S. (2024) · Photonics Research · doi:10.1364/prj.508136 · Cited by 233
Self-citation
Metadata
- Authors
- Lyu, J., Shen, S., Chen, L., Zhu, Y., & Zhuang, S.
- Venue
- PhotoniX
- Published
- 2023-09-19
- Volume
- 4
- Issue
- 1
- ISSN
- 2662-1991 (ISSN-L)
- OpenAlex
- W4386849301
- Cited by
- 161
- References
- 33
- FWCI
- 11.80
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.