CoChat

Assessment of sensitivity of acoustic reflex decay test in diagnosis of patulous eustachian tube

Open access
Attia, Alia Ali Ahmed, Abou-Setta, Alaa Eldin Ahmed, Ashary, Yehia Mohammed · 2024 · The Egyptian Journal of Otolaryngology

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index; none of the 19 sources its claims cite is checked for support yet.

Abstract

Background: It has long been believed that the patulous eustachian tube is a unique but uncommon condition, with an estimated incidence ranging from 0.3 to 6.6% in the general population. Hearing one’s own voice and breathing, or autophony and aerophony, are the most common symptoms of PET, along with frequent auditory fullness. Aim: This study is to establish a standardized protocol for the audiological evaluation of patulous Eustachian tube using acoustic reflex decay test during different breathing tasks. Methods: Between January 2022 and December 2022, the ENT department at Suez Canal University Hospitals undertook an observational case-control study. Fifty-two adult patients who present to the Suez Canal University ENT department with complaints of autophony, auditory fullness, or aerophony are diagnosed with patulous eustachian tube dysfunction through endoscopic examination of the tympanic membrane’s synchronized movement with respiration. Results: The incidence rate of PET among adults was approximately 3 patients/1000 patients/year. The age of the whole studied group ranged from 20 to 60 years with mean ± SD of 37.4 ± 12.6 years. They included 23 males (44.2%) and 29 females (55.8%). The most common symptom among the studied group was aural fullness (46%), while the least common symptom was aerophony (12%); the most common risk factor among the studied patients was allergy (46.2%), while the least common was radiotherapy (3.9%); 66.7% of the patients with GERD were males, while 66.7% of the patients who lost weight were females; 58.3% of the patients with allergies were females, and also 60% of the patients with thin built were females. In the case group, there is a significant higher change of middle ear compliance in ipsilateral nostril breathing than the mouth breathing and nasal breathing. The sensitivity of the acoustic reflex decay test to diagnose PET with reference to the gold standard test is 88.5% (23/26*100), the specificity is 100% (26/26*100), and the positive predictive value is 100% (23/23*100). Conclusion: The sensitivity of the acoustic reflex decay test to diagnose PET with reference to the gold standard test is high, and the specificity is very high with very good diagnostic accuracy.

Overview

CoChat Summary

TL;DR

This observational case-control study assessed acoustic reflex decay testing against endoscopic tympanic-membrane movement for diagnosing patulous Eustachian tube (PET). It reports high sensitivity (88.5%), very high specificity (100%), and 94.2% diagnostic accuracy, with ipsilateral nostril breathing the most sensitive breathing task.

Key findings

  • The acoustic reflex decay test had sensitivity 88.5% (23/26), specificity 100% (26/26), positive predictive value 100% (23/23), negative predictive value 89.7% (26/29), and diagnostic accuracy 94.2% ((23+26)/52) versus the gold standard endoscopic test.
  • Middle-ear compliance change was significantly higher in cases than controls for mouth breathing (0.08 ± 0.04 vs 0.01 ± 0.01 ml, P < 0.001), nasal breathing (0.14 ± 0.07 vs 0.03 ± 0.04 ml, P < 0.001), and ipsilateral nostril breathing (0.34 ± 0.12 vs 0.05 ± 0.06 ml, P < 0.001); ipsilateral nostril breathing was the most sensitive step.
  • The estimated incidence rate of PET among adults was approximately 3 patients/1000 patients/year.
  • Among studied cases, the most common risk factor was allergy (46.2%) and the least common was radiotherapy (3.9%); the most common symptom reported was aural fullness (46%) and the least common was aerophony (12%).

Methods

  • Observational case-control study conducted January–December 2022 in the ENT department at Suez Canal University Hospitals, including 52 adults divided into 26 PET cases and 26 controls; cases were diagnosed by endoscopic examination showing synchronous tympanic-membrane movement with respiration.
  • Acoustic reflex decay testing used a Clarinet Inventis Middle Ear Analyzer with a 226 Hz probe tone, stimulus set 10 dB above ART at 500 Hz, and was repeated during mouth breathing, nasal breathing, and ipsilateral nostril breathing with mouth closure.
  • Statistical analysis used SPSS version 26, including Kolmogorov-Smirnov, chi-square, and Mann-Whitney U tests, with P < 0.05 considered significant.

Limitations

  • The paper states that some patients could not perform breathing exercises correctly, especially the ipsilateral nostril breathing step; it also cites the low incidence rate of PET and difficulty recruiting patients for the case group.
  • The paper cautions that correlations between risk factors and gender should be interpreted cautiously and may be clearer with a larger sample size.
  • Evident from the text: the study used a small single-center sample (N = 52) and convenient sampling, and no blinding of the acoustic reflex decay test or gold standard assessment is described.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1186/s43163-024-00579-4

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Fig. 1 Pie chart displaying the relative frequency (%) of the symptoms among the studied cases ( n = 26)
Fig. 1 Pie chart displaying the relative frequency (%) of the symptoms among the studied cases ( n = 26)CC-BY · From the PDF
Fig. 2 Pie chart displaying the relative frequency (%) of the risk factors among the studied cases ( n = 26)
Fig. 2 Pie chart displaying the relative frequency (%) of the risk factors among the studied cases ( n = 26)CC-BY · From the PDF
Fig. 3 Bar chart displaying the frequency of the results of the acoustic reflex decay test among cases and controls
Fig. 3 Bar chart displaying the frequency of the results of the acoustic reflex decay test among cases and controlsCC-BY · From the PDF

Verification

Claims the paper makes

0 Valid · 4 Not valid · 17 Not checked · 39 Own results and interpretations

16 more claims

Create a free account to see all 60 claims and to verify the 18 references still open.

See all claims — free account
  • It may state two separate claims as one. 19
  • Probably not a substantial claim. 32

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

4 of 4

Citations

Cites

Show all 22 references

Research works printed but not linked: 1

  1. Dawson B, Trapp RG (2004) Basic and clinical biostatistics. vol. 192, ALANGE medical book. 141–142

Cited by

Still being checked.

Metadata

Authors
Attia, A. A. A., Abou-Setta, A. E. A., & Ashary, Y. M.
Affiliations
Suez Canal University (EG)
Corresponding author
Attia, Alia Ali Ahmed
Venue
The Egyptian Journal of Otolaryngology
Published
2024-02-19
Volume
40
Issue
1
Pages
24
ISSN
  • 1012-5574 (ISSN-L)
  • 2090-8539
OpenAlex
W4391930672
Cited by
0
References
21
FWCI
0.00
Type
journal article
Language
en
Open access
Licence
Locations
  • The Egyptian Journal of Otolaryngology (publishedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Health Sciences › Medicine › Otorhinolaryngology › Ear Surgery and Otitis Media
  • Life Sciences › Neuroscience › Sensory Systems › Hearing, Cochlea, Tinnitus, Genetics
  • Life Sciences › Neuroscience › Neurology › Vestibular and auditory disorders
Keywords
patulous Eustachian tube, sensitivity and specificity, autophony, aural fullness, middle ear compliance, breathing pattern, nasal breathing, mouth breathing, allergy, diagnostic accuracy, Eustachian tube dysfunction, risk factors, GERD, weight loss, radiotherapy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-21, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-21 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of sensitivity of acoustic reflex decay test in diagnosis of patulous eustachian tube. https://app.cochat.ai/papers/10.1186/s43163-024-00579-4
The paper
Attia, A. A. A., Abou-Setta, A. E. A., & Ashary, Y. M. (2024). Assessment of sensitivity of acoustic reflex decay test in diagnosis of patulous eustachian tube. The Egyptian Journal of Otolaryngology. https://doi.org/10.1186/s43163-024-00579-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.