The limited available data on human internal exposure poses a significant challenge in assessing the risks associated with micro and nanoplastics (MNPs) to human health. A contributing factor to this challenge is the scarcity of sensitive analytical methods to quantify the mass concentration of plastic polymers in human blood. In this study we present an improved and validated method for quantitatively analysing polyethylene (PE), polyethylene terephthalate (PET), poly(vinyl chloride) (PVC), poly(methyl methacrylate) (PMMA), polypropylene, and polystyrene in human whole blood samples. We introduce and apply stringent quality assurance and quality control procedures, including the validation of the method using quality control samples and continuous monitoring of batch analyses to ensure data reliability. Expanding upon prior pioneering work by Leslie et al. (2022), we optimised the pyrolysis-gas chromatography–mass spectrometry (Py-GC-MS) conditions to enhance method sensitivity and selectivity. Recovery experiments demonstrated a high level of accuracy and precision, with values ranging from 68 to 109% for quality control samples. Applying this method to whole blood samples (n = 68), we identified plastic polymers in 64 samples, with PE as the predominant polymer, followed by PVC, PET, and PMMA. In 17 blood samples, polymer concentrations were found to exceed the limit of quantitation, with a mean of 1070 ng/mL for the summed polymer concentrations, ranging between 170 and 2490 ng/mL. The mean of the sum of polymers across all blood samples (n = 68) was 268 ng/mL. These findings underscore the pressing need for further research aimed at comprehensive MNP quantification in human matrices, considering the potential health implications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s43591-024-00090-w

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 127

Metadata

Authors
Brits, M., van Velzen, M. J. M., Sefiloglu, F. Ö., Scibetta, L., Groenewoud, Q., Garcia-Vallejo, J. J., Vethaak, A. D., Brandsma, S. H., & Lamoree, M. H.
Venue
Microplastics and Nanoplastics
Published
2024-06-24
Volume
4
Issue
1
ISSN
2662-4966 (ISSN-L)
OpenAlex
W4399964591
Cited by
127
References
11
FWCI
11.46
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantitation of micro and nanoplastics in human blood by pyrolysis-gas chromatography–mass spectrometry. https://app.cochat.ai/papers/10.1186/s43591-024-00090-w
The paper
Brits, M., van Velzen, M. J. M., Sefiloglu, F. Ö., Scibetta, L., Groenewoud, Q., Garcia-Vallejo, J. J., Vethaak, A. D., Brandsma, S. H., & Lamoree, M. H. (2024). Quantitation of micro and nanoplastics in human blood by pyrolysis-gas chromatography–mass spectrometry. Microplastics and Nanoplastics. https://doi.org/10.1186/s43591-024-00090-w

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.