CoChat

Advances and Applications of Multiplexed Diagnostic Technologies in Autoimmune Diseases

Fritzler, MJ · 2006 · Lupus

The DOI matches its Crossref record; 29 of the 30 references it cites were found in a registry or an index.

Abstract

There is a rapid proliferation of new technologies to identify an ever increasing spectrum of autoantibodies in diverse medical conditions that range from organ-specific autoimmune diseases to systemic rheumatic diseases. Although many laboratories have adopted diagnostic platforms, such as enzyme linked immunoassays (ELISAs), to improve turn around times and meet budget constraints, the prevailing evidence is that the rapid adoption of new technologies is not attended by an appropriate balance of assay sensitivity and specificity. Emerging diagnostic technologies include addressable laser bead immunoassays, microarrays in microfluidics platforms and nanobarcode particles. Although these technologies provide advantages of high-throughput, multiplexed autoantibody assays that can be coupled to other disease specific biomarkers (ie, cytokines, single nucleotide polymorphisms) there is a clear need for standardization and internal validation before they are adopted into the clinical diagnostic laboratory.

Overview

Integrity signals

Registry

Crossref · 10.1191/0961203306lu2327oa

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 29 references

Research works printed but not linked: 8

  1. Craft J, 1987, J Rheumatol, 14, 106
  2. Harley JB, 1995, J Lab Clin Med, 126, 509
  3. 2000, Med Device Technol, 11, 33
  4. Meheus L, 1999, Clin Exp Rheumatol, 17, 205
  5. van der Linden MW, 2001, J Rheumatol, 28, 284
  6. Freeman RG, 2005, Methods Mol Biol, 303, 73
  7. 10.1309/gjhk0d24yddxw0nf · doi:10.1309/gjhk0d24yddxw0nf · Paper page
  8. Kniss R., 1998, Amer Lab, 30, 40

Cited by

See all 78

Metadata

Authors
Fritzler, M.
Affiliations
Department of Medicine, Faculty of Medicine, University of Calgary, Calgary, Alberta, Canada,
Venue
Lupus
Published
2006-07
Volume
15
Issue
7
Pages
422-427
ISSN
  • 0961-2033 (ISSN-L)
  • 1477-0962
OpenAlex
W1989885720
Cited by
78
References
30
Citations by year
2026: 1 · 2025: 1 · 2024: 1 · 2023: 1 · 2022: 1 · 2021: 1 · 2020: 1 · 2019: 3 · 2018: 5 · 2017: 1 · 2016: 5 · 2015: 3 · 2014: 4 · 2013: 6 · 2012: 4
FWCI
0.85
Type
journal article
Language
en
Open access
closed
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
Locations
  • Lupus (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced Biosensing Techniques and Applications
  • Health Sciences › Medicine › Rheumatology › Systemic Lupus Erythematosus Research
  • Health Sciences › Medicine › Clinical Neurology › Multiple Sclerosis Research Studies
Keywords
autoantibodies, multiplex immunoassay, autoimmune disease, rheumatic diseases, assay sensitivity and specificity, biomarkers, internal validation
MeSH terms
Animals, Autoantibodies, Autoimmune Diseases, Enzyme-Linked Immunosorbent Assay, Humans, Immunoassay, Clinical Laboratory Techniques, Protein Array Analysis, Microfluidics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Advances and Applications of Multiplexed Diagnostic Technologies in Autoimmune Diseases. https://app.cochat.ai/papers/10.1191/0961203306lu2327oa
The paper
Fritzler, M. (2006). Advances and Applications of Multiplexed Diagnostic Technologies in Autoimmune Diseases. Lupus. https://doi.org/10.1191/0961203306lu2327oa

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.