Monitoring manual control of electric lighting and blinds
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
This paper reviews, validates and extends present knowledge of the degree and kind of manual control strategies of blinds and electric lighting systems that are used in private and two-person offices. A new monitoring setup was applied from March to December 2000 in 10 daylit offices in Germany that featured manually operated electric lighting and automatically controlled external venetian blinds with manual override. The data shows that individuals consistently followed the same control strategy for their electric lighting and blinds. Groups of individuals tended to activate their electric lighting according to Hunt’s probability function, although there was a large spread between individual control levels. All subjects used their blinds to avoid direct sunlight above 50 W/m 2, and incoming solar gains above 50 klux (~450 W/m 2). They also were more willing to accept automatic blind opening than closing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Validation of dynamic RADIANCE-based daylight simulations for a test office with external blinds
Reinhart, C. F., & Walkenhorst, O. (2001) · Energy and Buildings · doi:10.1016/s0378-7788(01)00058-5 · Cited by 730
Self-citationReinhart, C. F., & Herkel, S. (2000) · Energy and Buildings · doi:10.1016/s0378-7788(00)00042-6 · Cited by 301
Self-citationThe use of artificial lighting in relation to daylight levels and occupancy
Hunt, D. R. G. (1979) · Building and Environment · doi:10.1016/0360-1323(79)90025-8 · Cited by 282
An innovative lighting controller integrated in a self-adaptive building control system
Guillemin, A., & Morel, N. (2001) · Energy and Buildings · doi:10.1016/s0378-7788(00)00100-6 · Cited by 208
Lee, E. S., DiBartolomeo, D. L., & Selkowitz, S. E. (1998) · Energy and Buildings · doi:10.1016/s0378-7788(98)00035-8 · Cited by 197
Newsham, G. R. (1994) · Indoor and Built Environment · doi:10.1177/1420326x9400300307 · Cited by 193
Window blind occlusion: a pilot study
Rea, M. S. (1984) · Building and Environment · doi:10.1016/0360-1323(84)90038-6 · Cited by 188
Office worker response to an automated Venetian blind and electric lighting system: a pilot study
Vine, E., Lee, E. S., Clear, R. D., DiBartolomeo, D. L., & Selkowitz, S. E. (1998) · Energy and Buildings · doi:10.1016/s0378-7788(98)00023-1 · Cited by 178
Comparison of Control Options in Private Offices in an Advanced Lighting Controls Testbed
Jennings, J., Rubinstein, F., DiBartolomeo, D. L., & Blanc, S. L. (2000) · Journal of the Illuminating Engineering Society · doi:10.1080/00994480.2000.10748316 · Cited by 147
Manual switching patterns in private offices
Love, J. A. (1998) · Lighting Research & Technology · doi:10.1177/096032719803000107 · Cited by 110
Cited by
Occupant behavior modeling for building performance simulation: Current state and future challenges
Yan, D., O’Brien, W., Hong, T., Feng, X., Burak Gunay, H., Tahmasebi, F., & Mahdavi, A. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.08.032 · Cited by 894
Galasiu, A. D., & Veitch, J. A. (2006) · Energy and Buildings · doi:10.1016/j.enbuild.2006.03.001 · Cited by 631
IEA EBC Annex 66: Definition and simulation of occupant behavior in buildings
Yan, D., Hong, T., Dong, B., Mahdavi, A., D’Oca, S., Gaetani, I., & Feng, X. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.09.084 · Cited by 508
The human dimensions of energy use in buildings: A review
D’Oca, S., Hong, T., & Langevin, J. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.08.019 · Cited by 394
Dubois, M.-C., & Blomsterberg, Å. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2011.07.001 · Cited by 361
Review of multi‐domain approaches to indoor environmental perception and behaviour
Schweiker, M., Ampatzi, E., Andargie, M. S., Andersen, R. K., Azar, E., Barthelmes, V. M., Berger, C., Bourikas, L., Carlucci, S., Chinazzo, G., et al. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.106804 · Cited by 330
Tällberg, R., Jelle, B. P., Loonen, R., Gao, T., & Hamdy, M. (2019) · Solar Energy Materials and Solar Cells · doi:10.1016/j.solmat.2019.02.041 · Cited by 310
CITYSIM: Comprehensive Micro-Simulation of Resource Flows for Sustainable Urban Planning
Robinson, D., Haldi, F., Leroux, P., Perez, D., Rasheed, A., & Wilke, U. (2009) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · doi:10.26868/25222708.2009.1083-1090 · Cited by 301
O'Brien, W., & Gunay, H. B. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.03.024 · Cited by 294
Gunay, H. B., O'Brien, W., & Beausoleil-Morrison, I. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.07.020 · Cited by 285
Manually-operated window shade patterns in office buildings: A critical review
O'Brien, W., Kapsis, K., & Athienitis, A. K. (2013) · Building and Environment · doi:10.1016/j.buildenv.2012.10.003 · Cited by 258
Stazi, F., Naspi, F., & D'Orazio, M. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.03.021 · Cited by 223
Daylight availability assessment and its potential energy saving estimation –A literature review
Yu, X., & Su, Y. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.07.142 · Cited by 221
The impacts of occupant behavior on building energy consumption: A review
Chen, S., Zhang, G., Xia, X., Chen, Y., Setunge, S., & Shi, L. (2021) · Sustainable Energy Technologies and Assessments · doi:10.1016/j.seta.2021.101212 · Cited by 205
Dynamic operation of daylighting and shading systems: A literature review
Konstantoglou, M., & Tsangrassoulis, A. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.12.246 · Cited by 197
Development and implementation of an adaptive lighting and blinds control algorithm
Gunay, H. B., O'Brien, W., Beausoleil-Morrison, I., & Gilani, S. (2017) · Building and Environment · doi:10.1016/j.buildenv.2016.08.027 · Cited by 190
Valitabar, M., GhaffarianHoseini, A., GhaffarianHoseini, A., & Attia, S. (2022) · Architectural Engineering and Design Management · doi:10.1080/17452007.2022.2032576 · Cited by 35
Metadata
- Authors
- Reinhart, C., & Voss, K.
- Venue
- Lighting Research & Technology
- Publisher
- SAGE Publications
- Published
- 2003-09
- Volume
- 35
- Issue
- 3
- Pages
- 243-258
- ISSN
- 0024-3426 (ISSN-L)
- 1477-1535
- 1477-0938
- OpenAlex
- W2031327648
- Cited by
- 344
- References
- 11
- FWCI
- 19.90
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.