7. An Overview of Active Structural Control under Seismic Loads
The DOI matches its Crossref record.
Abstract
The concept of active structural control as a means of structural protection against seismic loads, developed over the last 20 years, has received considerable attention in recent years. It has now reached the stage where active systems have been installed in full‐scale structures. It is the purpose of this paper to provide an overview of this development with special emphasis placed on laboratory experiments using model structures and on full‐scale implementation of some active control systems. Included in this paper is a report on the formation of a U.S. Panel on Structural Control Research and some discussion on possible future research directions in this exciting research area.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Phenomenological Model for Magnetorheological Dampers
Spencer, B. F., Dyke, S. J., Sain, M. K., & Carlson, J. D. (1997) · Journal of Engineering Mechanics · doi:10.1061/(asce)0733-9399(1997)123:3(230 · Cited by 2,055
Semi-active control systems for seismic protection of structures: a state-of-the-art review
Symans, M. D., & Constantinou, M. C. (1999) · Engineering Structures · doi:10.1016/s0141-0296(97)00225-3 · Cited by 706
Integrating structural control, health monitoring, and energy harvesting for smart cities
Javadinasab Hormozabad, S., Gutierrez Soto, M., & Adeli, H. (2021) · Expert Systems · doi:10.1111/exsy.12845 · Cited by 158
Miah, M. S., Chatzi, E. N., Dertimanis, V. K., & Weber, F. (2017) · Structural Control and Health Monitoring · doi:10.1002/stc.1878 · Cited by 39
Seismic structural control using an electric servomotor active mass driver system
Lee, C., & Wang, Y. (2004) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.373 · Cited by 22
“Structural control systems that have been implemented include passive, semi-active, active and hybrid devices [1–4].”
Background
Metadata
- Authors
- Soong, T. T., Masri, S. F., & Housner, G. W.
- Venue
- Earthquake Spectra
- Publisher
- Wiley
- Published
- 1991-08
- Volume
- 7
- Issue
- 3
- Pages
- 483-505
- ISSN
- 1944-8201 (ISSN-L)
- 8755-2930
- OpenAlex
- W2024589821
- Cited by
- 71
- References
- 0
- FWCI
- 17.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.