Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 193

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Highly sensitive quantification of key regulatory oxysterols in biological samples by LC-ESI-MS/MS

Open access
Honda, Akira, Yamashita, Kouwa, Hara, Takashi, Ikegami, Tadashi, Miyazaki, Teruo, Shirai, Mutsumi, Xu, Guorong, Numazawa, Mitsuteru, Matsuzaki, Yasushi · 2009 · Journal of Lipid Research

Abstract

We describe a highly sensitive and specific method for the quantification of key regulatory oxysterols in biological samples. This method is based upon a stable isotope dilution technique by liquid chromatography-tandem mass spectrometry (LC-MS/MS). After alkaline hydrolysis of human serum (5 microl) or rat liver microsomes (1 mg protein), oxysterols were extracted, derivatized into picolinyl esters, and analyzed by LC-MS/MS using the electrospray ionization mode. The detection limits of the picolinyl esters of 4beta-hydroxycholesterol, 7alpha-hydroxycholesterol, 22R-hydroxycholesterol, 24S-hydroxycholesterol, 25-hydroxycholesterol, 27-hydroxycholesterol, and 24S,25-epoxycholesterol were 2-10 fg (5-25 amol) on-column (signal-to-noise ratio = 3). Reproducibilities and recoveries of these oxysterols were validated according to one-way layout and polynomial equation, respectively. The variances between sample preparations and between measurements by this method were calculated to be 1.8% to 12.7% and 2.9% to 11.9%, respectively. The recovery experiments were performed using rat liver microsomes spiked with 0.05 ng to 12 ng of oxysterols, and recoveries of the oxysterols ranged from 86.7% to 107.3%, with a mean recovery of 100.6%. This method provides reproducible and reliable results for the quantification of oxysterols in small amounts of biological samples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1194/jlr.d800040-jlr200

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 193

Metadata

Authors
Honda, A., Yamashita, K., Hara, T., Ikegami, T., Miyazaki, T., Shirai, M., Xu, G., Numazawa, M., & Matsuzaki, Y.
Venue
Journal of Lipid Research
Publisher
Elsevier BV
Published
2009-02
Volume
50
Issue
2
Pages
350-357
ISSN
0022-2275 (ISSN-L)
OpenAlex
W1976803011
Cited by
193
References
1
FWCI
10.02
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Highly sensitive quantification of key regulatory oxysterols in biological samples by LC-ESI-MS/MS. https://app.cochat.ai/papers/10.1194/jlr.d800040-jlr200
The paper
Honda, A., Yamashita, K., Hara, T., Ikegami, T., Miyazaki, T., Shirai, M., Xu, G., Numazawa, M., & Matsuzaki, Y. (2009). Highly sensitive quantification of key regulatory oxysterols in biological samples by LC-ESI-MS/MS. Journal of Lipid Research. https://doi.org/10.1194/jlr.d800040-jlr200

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.