Oral Fluid Nanosensor Test (OFNASET) with Advanced Electrochemical‐Based Molecular Analysis Platform
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
High‐impact diseases, including cancer, cardiovascular disease, and neurological disease, are challenging to diagnose without supplementing clinical evaluation with laboratory testing. Even with laboratory tools, definitive diagnosis often remains elusive. The lack of three crucial elements presents a road block to achieving the potential of clinical diagnostic tests: (1) definitive disease‐associated protein and genetic markers, (2) easy and inexpensive sampling methods with minimal discomfort for the subject, and (3) an accurate and quantitative diagnostic platform. Our aim is to develop and validate a solution for requirement (3) and also to develop a portable system. Requirements (1) and (2) will be addressed through the utilization of novel and highly specific oral cancer saliva proteomic and genomic biomarkers and the use of saliva as the biofluid of choice, respectively. The Oral Fluid NanoSensor Test (OFNASET) technology platform combines cutting‐edge technologies, such as self‐assembled monolayers (SAM), bionanotechnology, cyclic enzymatic amplification, and microfluidics, with several well‐established techniques including microinjection molding, hybridization‐based detection, and molecular purification. The intended use of the OFNASET is for the point of care multiplex detection of salivary biomarkers for oral cancer. We have demonstrated that the combination of two salivary proteomic biomarkers (thioredoxin and IL‐8) and four salivary mRNA biomarkers (SAT, ODZ, IL‐8, and IL‐1b) can detect oral cancer with high specificity and sensitivity. Our preliminary studies have shown compelling results. We sequentially delivered a serial dilution of IL‐8 antigen, probe solution, wash, enzyme solution, wash, and mediator solution to sensor reaction chambers housed in a prototype cartridge and demonstrated strong signal separation at 50 pg/mL above a negative control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Drummond, T. G., Hill, M. G., & Barton, J. K. (2003) · Nature Biotechnology · doi:10.1038/nbt873 · Cited by 2,214
Cited by
Association between periodontal pathogens and systemic disease
Bui, F. Q., Almeida-da-Silva, C. L. C., Huynh, B., Trinh, A., Liu, J., Woodward, J., Asadi, H., & Ojcius, D. M. (2019) · Biomedical Journal · doi:10.1016/j.bj.2018.12.001 · Cited by 829
Measurement of biomarker proteins for point-of-care early detection and monitoring of cancer
Rusling, J. F., Kumar, C. V., Gutkind, J. S., & Patel, V. (2010) · The Analyst · doi:10.1039/c0an00204f · Cited by 552
Integrating Artificial Intelligence and Nanotechnology for Precision Cancer Medicine
Adir, O., Poley, M., Chen, G., Froim, S., Krinsky, N., Shklover, J., Shainsky‐Roitman, J., Lammers, T., & Schroeder, A. (2020) · Advanced Materials · doi:10.1002/adma.201901989 · Cited by 496
Malamud, D. (2011) · Dental Clinics of North America · doi:10.1016/j.cden.2010.08.004 · Cited by 489
Saliva diagnostics – Current views and directions
Kaczor-Urbanowicz, K. E., Martin Carreras-Presas, C., Aro, K., Tu, M., Garcia-Godoy, F., & Wong, D. T. (2017) · Experimental Biology and Medicine · doi:10.1177/1535370216681550 · Cited by 472
Self-citation
Metadata
- Authors
- GAU, V., & WONG, D.
- Venue
- Annals of the New York Academy of Sciences
- Publisher
- Wiley
- Published
- 2007-03
- Volume
- 1098
- Issue
- 1
- Pages
- 401-410
- ISSN
- 0077-8923 (ISSN-L)
- 1749-6632
- OpenAlex
- W2047353516
- Cited by
- 100
- References
- 1
- FWCI
- 1.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.