Does End‐tidal Carbon Dioxide Monitoring Detect Respiratory Events Prior to Current Sedation Monitoring Practices?

Burton, John H., Harrah, John D., Germann, Carl A., Dillon, Douglas C. · 2006 · Academic Emergency Medicine

Abstract

Objectives: The value of ventilation monitoring with end‐tidal carbon dioxide (ETCO 2) to anticipate acute respiratory events during emergency department (ED) procedural sedation and analgesia (PSA) is unclear. The authors sought to determine if ETCO 2 monitoring would reveal findings indicating an acute respiratory event earlier than indicated by current monitoring practices. Methods: The study included a prospective convenience sample of ED patients undergoing PSA. Clinicians performed ED PSA procedures with generally accepted patient monitoring, including oxygen saturation (SpO 2), and clinical ventilation assessment. A study investigator recorded ETCO 2 levels and respiratory events during each PSA procedure, with clinical providers blinded to ETCO 2 levels. Acute respiratory events were defined as SpO 2≤92%, increases in the amount of supplemental oxygen provided, use of bag‐valve mask or oral/nasal airway for ventilatory assistance, repositioning or airway alignment maneuvers, and use of physical or verbal means to stimulate patients with depressed ventilation or apnea, and reversal agent administration. Results: Enrollment was stopped after independent review of 20 acute respiratory events in 60 patient sedation encounters (33%). Abnormal ETCO 2 findings were documented in 36 patients (60%). Seventeen patients (85%) with acute respiratory events demonstrated ETCO 2 findings indicative of hypoventilation or apnea during PSA. Abnormal ETCO 2 findings were documented before changes in SpO 2 or clinically observed hypoventilation in 14 patients (70%) with acute respiratory events. Conclusions: Abnormal ETCO 2 findings were observed with many acute respiratory events. A majority of patients with acute respiratory events had ETCO 2 abnormalities that occurred before oxygen desaturation or observed hypoventilation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1197/j.aem.2005.12.017

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 177

Metadata

Authors
Burton, J. H., Harrah, J. D., Germann, C. A., & Dillon, D. C.
Venue
Academic Emergency Medicine
Publisher
Wiley
Published
2006-05
Volume
13
Issue
5
Pages
500-504
ISSN
  • 1069-6563 (ISSN-L)
  • 1553-2712
OpenAlex
W2067026957
Cited by
177
References
0
FWCI
12.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Does End‐tidal Carbon Dioxide Monitoring Detect Respiratory Events Prior to Current Sedation Monitoring Practices? https://app.cochat.ai/papers/10.1197/j.aem.2005.12.017
The paper
Burton, J. H., Harrah, J. D., Germann, C. A., & Dillon, D. C. (2006). Does End‐tidal Carbon Dioxide Monitoring Detect Respiratory Events Prior to Current Sedation Monitoring Practices? Academic Emergency Medicine. https://doi.org/10.1197/j.aem.2005.12.017

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.