The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A Prospective Comparison of Ultrasound-guided and Blindly Placed Radial Arterial Catheters
Open accessAbstract
BACKGROUND: Arterial cannulation for continuous blood-pressure measurement and frequent arterial-blood sampling commonly are required in critically ill patients. OBJECTIVES: To compare ultrasound (US)-guided versus traditional palpation placement of arterial lines for time to placement, number of attempts, sites used, and complications. METHODS: This was a prospective, randomized interventional study at a Level 1 academic urban emergency department with an annual census of 78,000 patients. Patients were randomized to either palpation or US-guided groups. Inclusion criteria were any adult patient who required an arterial line according to the treating attending. Patients who had previous attempts at an arterial line during the visit, or who could not be randomized because of time constraints, were excluded. Enrollment was on a convenience basis, during hours worked by researchers over a six-month period. Patients in either group who had three failed attempts were rescued with the other technique for patient comfort. Statistical analysis included Fisher's exact, Mann-Whitney, and Student's t-tests. RESULTS: Sixty patients were enrolled, with 30 patients randomized to each group. Patients randomized to the US group had a shorter time required for arterial line placement (107 vs. 314 seconds; difference, 207 seconds; p = 0.0004), fewer placement attempts (1.2 vs. 2.2; difference, 1; p = 0.001), and fewer sites required for successful line placement (1.1 vs. 1.6; difference, 0.5; p = 0.001), as compared with the palpation group. CONCLUSIONS: In this study, US guidance for arterial cannulation was successful more frequently and it took less time to establish the arterial line as compared with the palpation method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Early goal-directed therapy in the treatment of severe sepsis and septic shock
Rivers, E., Nguyen, B., Havstad, S., Ressler, J., Muzzin, A., Knoblich, B., Peterson, E., & Tomlanovich, M. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa010307 · Cited by 10,743
Costantino, T. G., Parikh, A. K., Satz, W. A., & Fojtik, J. P. (2005) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2004.12.026 · Cited by 435
Cited by
Frankel, H. L., Kirkpatrick, A. W., Elbarbary, M., Blaivas, M., Desai, H., Evans, D., Summerfield, D. T., Slonim, A., Breitkreutz, R., Price, S., et al. (2015) · Critical Care Medicine · doi:10.1097/ccm.0000000000001216 · Cited by 494
Self-citationTroianos, C. A., Hartman, G. S., Glas, K. E., Skubas, N. J., Eberhardt, R. T., Walker, J. D., & Reeves, S. T. (2011) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.09.021 · Cited by 420
Radial Artery Cannulation: A Comprehensive Review of Recent Anatomic and Physiologic Investigations
Brzezinski, M., Luisetti, T., & London, M. J. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181bbd416 · Cited by 354
Lamperti, M., Biasucci, D. G., Disma, N., Pittiruti, M., Breschan, C., Vailati, D., Subert, M., Traškaitė, V., Macas, A., Estebe, J.-P., et al. (2020) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000001180 · Cited by 316
Ultrasound Guidance Facilitates Radial Artery Catheterization
Gu, W.-J., Wu, X.-D., Wang, F., Ma, Z.-L., & Gu, X.-P. (2016) · Chest · doi:10.1378/chest.15-1784 · Cited by 109
Metadata
- Authors
- Shiver, S., Blaivas, M., & Lyon, M.
- Venue
- Academic Emergency Medicine
- Publisher
- Wiley
- Published
- 2006-12
- Volume
- 13
- Issue
- 12
- Pages
- 1275-1279
- ISSN
- 1069-6563 (ISSN-L)
- 1553-2712
- OpenAlex
- W1971719013
- Cited by
- 173
- References
- 2
- FWCI
- 4.29
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.