A Pilot Study of Ultrasound Analysis before Pediatric Peripheral Vein Cannulation Attempt
The DOI matches its OpenAlex record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: To determine whether peripheral veins can be detected by ultrasound (US) and to determine vein characteristics, as measured by US, that are associated with successful peripheral venous (PV) catheterization in young children. METHODS: The authors conducted an observational study in the pediatric emergency department (ED), with a convenience sample of children younger than 7 years. They evaluated attempts at PV catheterization in two groups on the basis of the visibility and palpability of the patients' veins: 1) clinically apparent (visible or palpable) and 2) not clinically apparent (nonvisible and nonpalpable). The authors obtained sonographic measurements in a transverse view (vertical diameter, circumference, and area) and in a longitudinal view (maximal uninterrupted length). Practitioners blinded to the US images then attempted to catheterize veins in the usual manner. The proportion of clinically apparent veins and the proportion of veins that were successfully catheterized that were identified by US were assessed, and the association between ultrasonographic vein measurements and success at catheterization, controlling for possible confounders, was determined. RESULTS: The authors assessed 120 attempts (90 clinically apparent and 30 not clinically apparent) at PV catheterization in 83 patients. US detected all 90 clinically apparent veins, and cannulation success rate was 62/90 (69%). In the not clinically apparent vein group, the rate of success was only 3/30 (10%), and US detected all successfully catheterized veins. In no instance was cannulation successful when the vein was not detected by US. Maximal vein length in longitudinal view was an independent predictor of cannulation success in multivariate analysis. CONCLUSIONS: Ultrasound appears to be capable of detecting peripheral veins in children younger than 7 years of age, with lack of US vein visualization likely leading to unsuccessful PV placement. Greater vein length visualization may be a useful predictor of successful PV catheterization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Costantino, T. G., Parikh, A. K., Satz, W. A., & Fojtik, J. P. (2005) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2004.12.026 · Cited by 435
Cited by
Failed attempts and improvement strategies in peripheral intravenous catheterization
Sabri, A., Szalas, J., Holmes, K. S., Labib, L., & Mussivand, T. (2013) · Bio-Medical Materials and Engineering · doi:10.3233/bme-120735 · Cited by 146
Carr, P. J., Rippey, J. C. R., Budgeon, C. A., Cooke, M. L., Higgins, N., & Rickard, C. M. (2016) · The Journal of Vascular Access · doi:10.5301/jva.5000487 · Cited by 122
Peripheral Difficult Venous Access in Children
Rauch, D., Dowd, D., Eldridge, D., Mace, S., Schears, G., & Yen, K. (2009) · Clinical Pediatrics · doi:10.1177/0009922809335737 · Cited by 80
Difficult peripheral venous access: recognizing and managing the patient at risk
Walsh, G. (2008) · Journal of the Association for Vascular Access · doi:10.2309/java.13-4-7 · Cited by 58
Metadata
- Authors
- Schnadower, D., Lin, S., Perera, P., Smerling, A., & Dayan, P. S.
- Venue
- Academic Emergency Medicine
- Publisher
- Wiley
- Published
- 2007-03-26
- Volume
- 14
- Issue
- 5
- Pages
- 483-485
- ISSN
- 1069-6563 (ISSN-L)
- OpenAlex
- W2074940410
- Cited by
- 54
- References
- 1
- FWCI
- 6.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Pilot Study of Ultrasound Analysis before Pediatric Peripheral Vein Cannulation Attempt. https://app.cochat.ai/papers/10.1111/j.1553-2712.2007.tb01812.x
- The paper
- Schnadower, D., Lin, S., Perera, P., Smerling, A., & Dayan, P. S. (2007). A Pilot Study of Ultrasound Analysis before Pediatric Peripheral Vein Cannulation Attempt. Academic Emergency Medicine. https://doi.org/10.1111/j.1553-2712.2007.tb01812.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.