The Evaluation of a Pulmonary Display to Detect Adverse Respiratory Events Using High Resolution Human Simulator
Open accessThe DOI matches its Crossref record.
Abstract
OBJECTIVE: Authors developed a picture-graphics display for pulmonary function to present typical respiratory data used in perioperative and intensive care environments. The display utilizes color, shape and emergent alerting to highlight abnormal pulmonary physiology. The display serves as an adjunct to traditional operating room displays and monitors. DESIGN: To evaluate the prototype, nineteen clinician volunteers each managed four adverse respiratory events and one normal event using a high-resolution patient simulator which included the new displays (intervention subjects) and traditional displays (control subjects). Between-group comparisons included (i) time to diagnosis and treatment for each adverse respiratory event; (ii) the number of unnecessary treatments during the normal scenario; and (iii) self-reported workload estimates while managing study events. MEASUREMENTS: Two expert anesthesiologists reviewed video-taped transcriptions of the volunteers to determine time to treat and time to diagnosis. Time values were then compared between groups using a Mann-Whitney-U Test. Estimated workload for both groups was assessed using the NASA-TLX and compared between groups using an ANOVA. P-values < 0.05 were considered significant. RESULTS: Clinician volunteers detected and treated obstructed endotracheal tubes and intrinsic PEEP problems faster with graphical rather than conventional displays (p < 0.05). During the normal scenario simulation, 3 clinicians using the graphical display, and 5 clinicians using the conventional display gave unnecessary treatments. Clinician-volunteers reported significantly lower subjective workloads using the graphical display for the obstructed endotracheal tube scenario (p < 0.001) and the intrinsic PEEP scenario (p < 0.03). CONCLUSION: Authors conclude that the graphical pulmonary display may serve as a useful adjunct to traditional displays in identifying adverse respiratory events.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Saleem, J. J., Russ, A. L., Sanderson, P., Johnson, T. R., Zhang, J., & Sittig, D. F. (2009) · Yearbook of Medical Informatics · doi:10.1055/s-0038-1638638 · Cited by 72
“It has been used in several domains to assess workload in complex environments, including for the evaluation of CISs, such as a pulmonary display [121] and computerized clinical reminders [122].”
MethodPollack, A. H., & Pratt, W. (2020) · JAMA Network Open · doi:10.1001/jamanetworkopen.2019.19301 · Cited by 53
Mazur, L. M., Mosaly, P. R., Moore, C., Comitz, E., Yu, F., Falchook, A. D., Eblan, M. J., Hoyle, L. M., Tracton, G., Chera, B. S., et al. (2016) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocw016 · Cited by 45
Metadata
- Authors
- Wachter, S. B., Johnson, K., Albert, R., Syroid, N., Drews, F., & Westenskow, D.
- Venue
- Journal of the American Medical Informatics Association
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-11-01
- Volume
- 13
- Issue
- 6
- Pages
- 635-642
- ISSN
- 1067-5027 (ISSN-L)
- 1527-974X
- OpenAlex
- W198012068
- Cited by
- 57
- References
- 0
- FWCI
- 4.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Evaluation of a Pulmonary Display to Detect Adverse Respiratory Events Using High Resolution Human Simulator. https://app.cochat.ai/papers/10.1197/jamia.m2123
- The paper
- Wachter, S. B., Johnson, K., Albert, R., Syroid, N., Drews, F., & Westenskow, D. (2006). The Evaluation of a Pulmonary Display to Detect Adverse Respiratory Events Using High Resolution Human Simulator. Journal of the American Medical Informatics Association. https://doi.org/10.1197/jamia.m2123
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.