CoChat

Impact of Clinical Reminder Redesign on Learnability, Efficiency, Usability, and Workload for Ambulatory Clinic Nurses

Open access
Saleem, J. J., Patterson, E. S., Militello, L., Anders, S., Falciglia, M., Wissman, J. A., Roth, E. M., Asch, S. M. · 2007 · Journal of the American Medical Informatics Association
Cited by 90

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Computerized clinical reminders (CRs) were designed to reduce clinicians' reliance on their memory and to present evidence-based guidelines at point of care. However, the literature indicates that CR adoption and effectiveness has been variable. We examined the impact of four design modifications to CR software on learnability, efficiency, usability, and workload for intake nursing personnel in an outpatient clinic setting. These modifications were included in a redesign primarily to address barriers to effective CR use identified during a previous field study. DESIGN: In a simulation experiment, 16 nurses used prototypes of the current and redesigned system in a within-subject comparison for five simulated patient encounters. Prior to the experimental session, participants completed an exploration session, where "learnability" of the current and redesigned systems was assessed. MEASUREMENTS: Time, performance, and survey data were analyzed in conjunction with semi-structured debrief interview data. RESULTS: The redesign was found to significantly increase learnability for first-time users as measured by time to complete the first CR, efficiency as measured by task completion time for two of five patient scenarios, usability as determined by all three groupings of questions taken from a commonly used survey instrument, and two of six workload subscales of the NASA Task Load Index (TLX) survey: mental workload and frustration. CONCLUSION: Modest design modifications to existing CR software positively impacted variables that likely would increase the willingness for first-time nursing personnel to adopt and consistently use CRs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1197/jamia.m2163

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 90

Metadata

Authors
Saleem, J. J., Patterson, E. S., Militello, L., Anders, S., Falciglia, M., Wissman, J. A., Roth, E. M., & Asch, S. M.
Venue
Journal of the American Medical Informatics Association
Published
2007-09-01
Volume
14
Issue
5
Pages
632-640
ISSN
  • 1067-5027 (ISSN-L)
  • 1527-974X
OpenAlex
W2158100229
Cited by
90
References
7
FWCI
9.75
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.