Assessing Data Quality in Manual Entry of Ventilator Settings
Open accessAbstract
OBJECTIVE: To evaluate the data quality of ventilator settings recorded by respiratory therapists using a computer charting application and assess the impact of incorrect data on computerized ventilator management protocols. DESIGN An analysis of 29,054 charting events gathered over 12 months from 678 ventilated patients (1,736 ventilator days) in four intensive care units at a tertiary care hospital. MEASUREMENTS: Ten ventilator settings were examined, including fraction of inspired oxygen (Fio (2)), positive end-expiratory pressure (PEEP), tidal volume, respiratory rate, peak inspiratory flow, and pressure support. Respiratory therapists entered values for each setting approximately every two hours using a computer charting application. Manually entered values were compared with data acquired automatically from ventilators using an implementation of the ISO/IEEE 11073 Medical Information Bus (MIB). Data quality was assessed by measuring the percentage of time that the two sources matched. Charting delay, defined as the interval between data observation and data entry, also was measured. RESULTS: The percentage of time that settings matched ranged from 99.0% (PEEP) to 75.9% (low tidal volume alarm setting). The average charting delay for each charting event was 6.1 minutes, including an average of 1.8 minutes spent entering data in the charting application. In 559 (3.9%) of 14,263 suggestions generated by computerized ventilator management protocols, one or more manually charted setting values did not match the MIB data. CONCLUSION: Even at institutions where manual charting of ventilator settings is performed well, automatic data collection can eliminate delays, improve charting efficiency, and reduce errors caused by incorrect data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In three of the four articles assessing currency, researchers reviewed whether desired data were entered into the EHR within a set time limit.
“In three of the four, researchers reviewed whether desired data were entered into the EHR within a set time limit.36 46 52”
From Methods and dimensions of electronic health record data quality assessment: enabling reuse for clinical research (2013) · cites this paper as [46]
The Methods (Data Analysis; page unavailable) say the researchers measured charting delay—the interval between observing ventilator settings and entering them into the computer—to assess timeliness. The Results report an average delay of 6.1 minutes, but the study does not assess whether entries met a set time limit. The 30-minute limit in the Background describes an earlier study by East et al., not this study's measure. (LLM, conf=0.85)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 36
- Akhtar, 2003, Chest, 124, 2275, 10.1378/chest.124.6.2275 · DOI
- Holt, 1993, Critical care medicine, 21, 144, 10.1097/00003246-199301000-00025 · DOI
- Soo Hoo, 2002, Chest, 121, 1947, 10.1378/chest.121.6.1947 · DOI
- DOJAT, 2000, American Journal of Respiratory and Critical Care Medicine, 161, 1161, 10.1164/ajrccm.161.4.9904064 · DOI
- 1989, SYMPOSIUM FOR COMPUTER APPLICATIONS IN MEDICAL CARE SCAMC, 13, 583
- Andrews, 1985, Respiratory Care, 30, 695
- Clemmer, 1985, Respiratory Care, 30, 586
- East, 1991, International journal of clinical monitoring and computing, 8, 263, 10.1007/BF01739127 · DOI
- Sittig, 1989, Computer methods and programs in biomedicine, 30, 77, 10.1016/0169-2607(89)90060-6 · DOI
- 2005, Journal of the American Medical Informatics Association, 12, 390, 10.1197/jamia.M1692 · DOI
- Blumenstein, 1993, Statistics in medicine, 12, 1535, 10.1002/sim.4780121702 · DOI
- Mullooly, 1990, Computers and biomedical research, an international journal, 23, 259, 10.1016/0010-4809(90)90020-D · DOI
- Benson, 2001, Methods of information in medicine, 40, 190, 10.1055/s-0038-1634166 · DOI · Paper page
- Edsall, 1993, Journal of clinical anesthesia, 5, 275, 10.1016/0952-8180(93)90118-X · DOI
- Edsall, 1997, Anesthesiology, 87, 721, 10.1097/00000542-199709000-00053 · DOI
- Block, 1991, Journal of clinical monitoring, 7, 141, 10.1007/BF01618113 · DOI
- Cook, 1989, Anesthesiology, 71, 385, 10.1097/00000542-198909001-00385 · DOI
- 1975, EUR J INTENS CARE MED, 1, 53, 10.1007/BF00626426 · DOI
- Turner, 1988, The Journal of neuroscience nursing : journal of the American Association of Neuroscience Nurses, 20, 236, 10.1097/01376517-198808000-00006 · DOI
- Cunningham, 1996, International journal of clinical monitoring and computing, 13, 235, 10.1023/A:1016967407632 · DOI
- Osborn, 1968, Surgery, 64, 1057
- Warner, 1968, Circulation, 37, II68
- Lewis, 1971, The Surgical clinics of North America, 51, 15, 10.1016/S0039-6109(16)39327-6 · DOI
- Peters, 1964, Surgery, 56, 44
- Blumenfeld, 1972, American journal of surgery, 123, 580, 10.1016/0002-9610(72)90224-3 · DOI
- Roccaforte, 1989, International journal of clinical monitoring and computing, 6, 123, 10.1007/BF01720423 · DOI
- Chambrin, 1989, International journal of clinical monitoring and computing, 6, 211, 10.1007/BF01733625 · DOI
- Shabot, 1989, International journal of clinical monitoring and computing, 6, 197, 10.1007/BF01733623 · DOI
- Kennelly, 1998, International journal of medical informatics, 48, 145, 10.1016/S1386-5056(97)00120-2 · DOI
- Garnsworthy, 1998, Medical device technology, 9, 18
- Gardner, 1989, International journal of clinical monitoring and computing, 6, 205, 10.1007/BF01733624 · DOI
- Morris, 1994, American Journal of Respiratory and Critical Care Medicine, 149, 295, 10.1164/ajrccm.149.2.8306022 · DOI
- East, 1992, Respiratory Care, 37, 1113
- Gardner, 1991, International journal of clinical monitoring and computing, 8, 251, 10.1007/BF01739125 · DOI
- 2005, Journal of the American Medical Informatics Association, 12, 589, 10.1197/jamia.M1863 · DOI
- Kennelly, 1997, International journal of clinical monitoring and computing, 14, 143, 10.1023/A:1016930319825 · DOI
Cited by
Sorted by citations
Weiskopf, N. G., & Weng, C. (2013) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2011-000681 · Cited by 1,216
Cusack, C. M., Hripcsak, G., Bloomrosen, M., Rosenbloom, S. T., Weaver, C. A., Wright, A., Vawdrey, D. K., Walker, J., & Mamykina, L. (2013) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2012-001093 · Cited by 103
Self-citation
Metadata
- Authors
- Vawdrey, D. K., Gardner, R. M., Evans, R. S., Orme, J. F., Clemmer, T. P., Greenway, L., & Drews, F. A.
- Affiliations
- Intermountain Healthcare (US)
- Corresponding author
- Vawdrey, D. K.
- ORCID
- Drews, F. A.
- Venue
- Journal of the American Medical Informatics Association
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-05-01
- Volume
- 14
- Issue
- 3
- Pages
- 295-303
- ISSN
- 1067-5027 (ISSN-L)
- 1527-974X
- PMC
- PMC2244881
- OpenAlex
- W2158305775
- Cited by
- 48
- References
- 0
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 2 · 2023: 1 · 2022: 1 · 2021: 3 · 2020: 3 · 2016: 3 · 2015: 2 · 2014: 4 · 2013: 2 · 2012: 3
- FWCI
- 11.78
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of the American Medical Informatics Association (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Intermountain Healthcare
- U.S. National Library of Medicine (# LM007124, T15LM007124)
- Topics
- Health Sciences › Health Professions › Health Information Management › Electronic Health Records Systems
- Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
- Health Sciences › Nursing › Research and Theory › Nursing Diagnosis and Documentation
- Keywords
- ventilator settings, data quality, ISO/IEEE 11073, respiratory therapists, intensive care unit, automated data collection, clinical decision support, data entry errors
- MeSH terms
- Data Collection, Forms and Records Control, Hospital Information Systems, Humans, Positive-Pressure Respiration, Prospective Studies, Ventilators, Mechanical, Respiratory Therapy, Therapy, Computer-Assisted, User-Computer Interface, Medical Records Systems, Computerized
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review