The DOI matches its Crossref record.
A Novel Hybrid Approach to Automated Negation Detection in Clinical Radiology Reports
Open accessAbstract
OBJECTIVE: Negation is common in clinical documents and is an important source of poor precision in automated indexing systems. Previous research has shown that negated terms may be difficult to identify if the words implying negations (negation signals) are more than a few words away from them. We describe a novel hybrid approach, combining regular expression matching with grammatical parsing, to address the above limitation in automatically detecting negations in clinical radiology reports. DESIGN: Negations are classified based upon the syntactical categories of negation signals, and negation patterns, using regular expression matching. Negated terms are then located in parse trees using corresponding negation grammar. MEASUREMENTS: A classification of negations and their corresponding syntactical and lexical patterns were developed through manual inspection of 30 radiology reports and validated on a set of 470 radiology reports. Another 120 radiology reports were randomly selected as the test set on which a modified Delphi design was used by four physicians to construct the gold standard. RESULTS: In the test set of 120 reports, there were a total of 2,976 noun phrases, of which 287 were correctly identified as negated (true positives), along with 23 undetected true negations (false negatives) and 4 mistaken negations (false positives). The hybrid approach identified negated phrases with sensitivity of 92.6% (95% CI 90.9-93.4%), positive predictive value of 98.6% (95% CI 96.9-99.4%), and specificity of 99.87% (95% CI 99.7-99.9%). CONCLUSION: This novel hybrid approach can accurately locate negated concepts in clinical radiology reports not only when in close proximity to, but also at a distance from, negation signals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Natural language processing: an introduction
Nadkarni, P. M., Ohno-Machado, L., & Chapman, W. W. (2011) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2011-000464 · Cited by 1,975
Savova, G. K., Kipper-Schuler, K. C., Hurdle, J. F., & Meystre, S. M. (2008) · Yearbook of Medical Informatics · doi:10.1055/s-0038-1638592 · Cited by 895
What can natural language processing do for clinical decision support?
Demner-Fushman, D., Chapman, W. W., & McDonald, C. J. (2009) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2009.08.007 · Cited by 688
The BioScope corpus: biomedical texts annotated for uncertainty, negation and their scopes
Vincze, V., Szarvas, G., Farkas, R., Móra, G., & Csirik, J. (2008) · BMC Bioinformatics · doi:10.1186/1471-2105-9-s11-s9 · Cited by 421
Harkema, H., Dowling, J. N., Thornblade, T., & Chapman, W. W. (2009) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2009.05.002 · Cited by 406
Metadata
- Authors
- Huang, Y., & Lowe, H. J.
- Venue
- Journal of the American Medical Informatics Association
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-05-01
- Volume
- 14
- Issue
- 3
- Pages
- 304-311
- ISSN
- 1067-5027 (ISSN-L)
- 1527-974X
- OpenAlex
- W2101891738
- Cited by
- 185
- References
- 0
- FWCI
- 5.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Novel Hybrid Approach to Automated Negation Detection in Clinical Radiology Reports. https://app.cochat.ai/papers/10.1197/jamia.m2284
- The paper
- Huang, Y., & Lowe, H. J. (2007). A Novel Hybrid Approach to Automated Negation Detection in Clinical Radiology Reports. Journal of the American Medical Informatics Association. https://doi.org/10.1197/jamia.m2284
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.