CoChat

Preliminary Development of the Physician Documentation Quality Instrument

Open access
Stetson, P. D., Morrison, F. P., Bakken, S., Johnson, S. B., For the eNote Research Team · 2008 · Journal of the American Medical Informatics Association
Cited by 70

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: This study sought to design and validate a reliable instrument to assess the quality of physician documentation. DESIGN: Adjectives describing clinician attitudes about high-quality clinical documentation were gathered through literature review, assessed by clinical experts, and transformed into a semantic differential scale. Using the scale, physicians and nurse practitioners scored the importance of the adjectives for describing quality in three note types: admission, progress, and discharge notes. Psychometric methods including exploratory factor analysis were applied to provide preliminary evidence for the construct validity and internal consistency reliability. RESULTS: A 22-item Physician Documentation Quality Instrument (PDQI) was developed. Exploratory factor analysis (n = 67 clinician respondents) on three note types resulted in solutions ranging from four (discharge) to six (admission and progress) factors, and explained 65.8% (discharge) to 73% (admission and progress) of the variance. Each factor solution was unique. However, four sets of items consistently factored together across all note types: (1) up-to-date and current; (2) brief, concise, succinct; (3) organized and structured; and (4) correct, comprehensible, consistent. Internal consistency reliabilities were: admission note (factor scales = 0.52-88, overall = 0.86), progress note (factor scales = 0.59-0.84, overall = 0.87), and discharge summary (factor scales = 0.76-0.85, overall = 0.88). CONCLUSION: The exploratory factor analyses and reliability analyses provide preliminary evidence for the construct validity and internal consistency reliability of the PDQI. Two novel dimensions of the construct for document quality were developed related to form (Well-formed, Compact). Additional work is needed to assess intrarater and interrater reliability of applying of the proposed instrument and to examine the reproducibility of the factors in other samples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1197/jamia.m2404

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 70

Metadata

Authors
Stetson, P. D., Morrison, F. P., Bakken, S., Johnson, S. B., & For the eNote Research Team
Venue
Journal of the American Medical Informatics Association
Published
2008-07-01
Volume
15
Issue
4
Pages
534-541
ISSN
  • 1067-5027 (ISSN-L)
  • 1527-974X
OpenAlex
W176313380
Cited by
70
References
2
FWCI
5.79
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Preliminary Development of the Physician Documentation Quality Instrument. https://app.cochat.ai/papers/10.1197/jamia.m2404
The paper
Stetson, P. D., Morrison, F. P., Bakken, S., Johnson, S. B., & For the eNote Research Team. (2008). Preliminary Development of the Physician Documentation Quality Instrument. Journal of the American Medical Informatics Association. https://doi.org/10.1197/jamia.m2404

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.