The DOI matches its Crossref record.
A prospective randomized trial comparing the infectious and noninfectious complications of an externalized catheter versus a subcutaneously implanted device in cancer patients.
Abstract
PURPOSE: To compare the frequency of infectious episodes or other problems occurring with an externalized catheter (Hickman) versus a subcutaneously implanted device (Port-a-Cath, Pharmacia, Piscataway, NJ) in cancer patients, we performed a prospective, randomized study in 100 cancer patients (age range, 5 to 74 years). PATIENTS AND METHODS: Patients who were chemotherapy candidates and required an indwelling catheter were monitored prospectively and evaluated during the 180 days after the insertion of the catheter and again at time of study closure. The frequency of catheter use, reason for access, and any problems that might have been related to catheter use were noted. All data were collected prospectively and included the patient's age, sex, underlying malignancy, temperature, and leukocyte and absolute granulocyte counts at the time of catheter insertion and when complications occurred. The time to and reason for removal of the catheter, as well as any intercurrent infectious or mechanical problems, were also determined. RESULTS: Most of the infections that occurred were caused by gram-positive organisms, especially staphylococci or streptococci. A total of 22 complications (11 in each group) resulted in removal of the central line. Only one infection in the Hickman catheter group and four in the Port-a-Cath group led to removal of the central line. All other infectious episodes were successfully treated without removal of the catheters. The mean device life was 230 days for the Hickman catheter and 318 days for the Port-a-Cath (not significant). CONCLUSION: There were no differences between the two study groups regarding incidence of documented infections or mechanical or thrombotic complications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Management of Fever in Patients with Cancer and Treatment-Induced Neutropenia
Wood, A. J. J., & Pizzo, P. A. (1993) · New England Journal of Medicine · doi:10.1056/nejm199305063281808 · Cited by 838
Self-citationVenous Thromboembolism Associated With Long-Term Use of Central Venous Catheters in Cancer Patients
Verso, M., & Agnelli, G. (2003) · Journal of Clinical Oncology · doi:10.1200/jco.2003.08.008 · Cited by 605
Allen-Mersh, T. G., Earlam, S., Fordy, C., Abrams, K., & Houghton, J. (1994) · The Lancet · doi:10.1016/s0140-6736(94)90750-1 · Cited by 534
Schiffer, C. A., Mangu, P. B., Wade, J. C., Camp-Sorrell, D., Cope, D. G., El-Rayes, B. F., Gorman, M., Ligibel, J., Mansfield, P., & Levine, M. (2013) · Journal of Clinical Oncology · doi:10.1200/jco.2012.45.5733 · Cited by 368
Vascular Access in Oncology Patients
Gallieni, M., Pittiruti, M., & Biffi, R. (2008) · CA: A Cancer Journal for Clinicians · doi:10.3322/ca.2008.0015 · Cited by 284
Metadata
- Authors
- Mueller, B. U., Skelton, J., Callender, D. P., Marshall, D., Gress, J., Longo, D., Norton, J., Rubin, M., Venzon, D., & Pizzo, P. A.
- Venue
- Journal of Clinical Oncology
- Published
- 1992-12
- Volume
- 10
- Issue
- 12
- Pages
- 1943-1948
- ISSN
- 0732-183X (ISSN-L)
- 1527-7755
- OpenAlex
- W2142366481
- Cited by
- 176
- References
- 0
- FWCI
- 17.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A prospective randomized trial comparing the infectious and noninfectious complications of an externalized catheter versus a subcutaneously implanted device in cancer patients. https://app.cochat.ai/papers/10.1200/jco.1992.10.12.1943
- The paper
- Mueller, B. U., Skelton, J., Callender, D. P., Marshall, D., Gress, J., Longo, D., Norton, J., Rubin, M., Venzon, D., & Pizzo, P. A. (1992). A prospective randomized trial comparing the infectious and noninfectious complications of an externalized catheter versus a subcutaneously implanted device in cancer patients. Journal of Clinical Oncology. https://doi.org/10.1200/jco.1992.10.12.1943
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.