CoChat

A prospective randomized trial comparing the infectious and noninfectious complications of an externalized catheter versus a subcutaneously implanted device in cancer patients.

Mueller, B U, Skelton, J, Callender, D P, Marshall, D, Gress, J, Longo, D, Norton, J, Rubin, M, Venzon, D, Pizzo, P A · 1992 · Journal of Clinical Oncology
Cited by 176

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

PURPOSE: To compare the frequency of infectious episodes or other problems occurring with an externalized catheter (Hickman) versus a subcutaneously implanted device (Port-a-Cath, Pharmacia, Piscataway, NJ) in cancer patients, we performed a prospective, randomized study in 100 cancer patients (age range, 5 to 74 years). PATIENTS AND METHODS: Patients who were chemotherapy candidates and required an indwelling catheter were monitored prospectively and evaluated during the 180 days after the insertion of the catheter and again at time of study closure. The frequency of catheter use, reason for access, and any problems that might have been related to catheter use were noted. All data were collected prospectively and included the patient's age, sex, underlying malignancy, temperature, and leukocyte and absolute granulocyte counts at the time of catheter insertion and when complications occurred. The time to and reason for removal of the catheter, as well as any intercurrent infectious or mechanical problems, were also determined. RESULTS: Most of the infections that occurred were caused by gram-positive organisms, especially staphylococci or streptococci. A total of 22 complications (11 in each group) resulted in removal of the central line. Only one infection in the Hickman catheter group and four in the Port-a-Cath group led to removal of the central line. All other infectious episodes were successfully treated without removal of the catheters. The mean device life was 230 days for the Hickman catheter and 318 days for the Port-a-Cath (not significant). CONCLUSION: There were no differences between the two study groups regarding incidence of documented infections or mechanical or thrombotic complications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1200/jco.1992.10.12.1943

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 176

Metadata

Authors
Mueller, B. U., Skelton, J., Callender, D. P., Marshall, D., Gress, J., Longo, D., Norton, J., Rubin, M., Venzon, D., & Pizzo, P. A.
Venue
Journal of Clinical Oncology
Published
1992-12
Volume
10
Issue
12
Pages
1943-1948
ISSN
  • 0732-183X (ISSN-L)
  • 1527-7755
OpenAlex
W2142366481
Cited by
176
References
7
FWCI
17.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.